This LG Display LB084S02 is work for COMEN C60 Patient Monitor.The
LB084S02 is a Color Active Matrix Liquid Crystal Display with an
integral Light Emitting Diode(LED) backlight system. The matrix
employs a-Si Thin Film Transistor as the active element. It is a
transmissive type display operating in the normally white mode.
This TFT-LCD has 8.4 inches diagonally measured active display area
with SVGA resolution(800 horizontal by 600 vertical pixel array).
Each pixel is divided into Red, Green and Blue sub-pixels or dots
which are arranged in vertical stripes. Gray scale or the
brightness of the sub-pixel color is determined with a 6-bit gray
scale signal for each dot, thus, presenting a palette of more than
262,144 colors.
The LB084S02 has been designed to apply the interface method that
enables low power, high speed, low EMI.
The LB084S02 is intended to support applications where thin
thickness, low power are critical factors and graphic displays are
important. In combination with the vertical arrangement of the
sub-pixels, the LB084S02 characteristics provide an excellent flat
display
► Specification
Active Screen Size | 8.4 inches diagonal |
Outline Dimension | 189.75x149.4x6.3mm |
Pixel Pitch | 0.071mm × 0.213mm |
Pixel Format | 800 horiz. by 600 vert. Pixels RGB strip arrangement |
Color Depth | 6-bit, 262,144 colors |
Luminance, White | 250 cd/m2 (Typ.) |
Weight | 300g(Typ.) |
Display Operating Mode | Transmitting type, normally white |
Surface Treatment | Anti-glare treatment of the front polarizer |
► Mounting Precautions
- You must mount a module using holes arranged in four corners or
four sides.
- You should consider the mounting structure so that uneven force
(ex. Twisted stress) is not applied to the module. And the case on
which a module is mounted should have sufficient strength so that
external force is not transmitted directly to the module.
- Please attach the surface transparent protective plate to the
surface in order to protect the polarizer.Transparent protective
plate should have sufficient strength in order to the resist
external force.
- You should adopt radiation structure to satisfy the temperature
specification.
- Acetic acid type and chlorine type materials for the cover case are
not desirable because the former generates corrosive gas of
attacking the polarizer at high temperature and the latter causes
circuit break by electro-chemical reaction.
- Do not touch, push or rub the exposed polarizers with glass,
tweezers or anything harder than HB pencil lead. And please do not
rub with dust clothes with chemical treatment. Do not touch the
surface of polarizer for bare hand or greasy cloth.(Some cosmetics
are detrimentalto the polarizer.)
- When the surface becomes dusty, please wipe gently with absorbent
cotton or other soft materials like chamois soaks with petroleum
benzene. Normal-hexane is recommended for cleaning the adhesives
used to attach front / rear polarizers. Do not use ace-tone,
toluene and alcohol because they cause chemical damage to the
polarizer.
- Wipe off saliva or water drops as soon as possible. Their long time
contact with polarizer causes deformations and color fading.
- Do not open the case because inside circuits do not have sufficient
strength.
Please kindly contact us, if you are interested in COMEN C60 Patient Monitor Display Screen LG LB084S02 , Thank you!
Company Profile
China World Technology Medical Equipment Service Group is a company
engaged in medical equipments/repair parts and accessories products
trading company. The company was established in September 2005, has
many famous enterprises at home and abroad (such as America USCO
company) to establish a long-term friendly business relationship.
Company mainly engaged in patient monitor and other medical machine
products. Since its inception continue to absorb a variety of
talents, improve product quality, improving staff quality, in order
to grow their companies. Strict quality guarantee system and
perfect management system, high-quality products after-sales
service is our foothold in this, my company of "quality first,
reputation first" principle, provide customers with quality and
quantity of various types of products. Always uPHiliphold the
"quality, integrity and pragmatic, motivated, service-oriented"
business PHiliphilosoPHiliphy, and applies the company's management
and operating among. The face of fierce competition, the company
system is constantly being improved, relying on science and
technology, continuously improve the technology content of products
sold, for society, customers and companies to create a higher
market value. Our company has been in good faith to create
enterprises, to credit management market, has won a good
reputation, also won the respect of their domestic counterparts.
Business strictly in accordance with relevant state laws,
regulations and rules of the WTO requirements management according
to law, actively participate in regional economic.Business
prospects and good, the next time, our company will expand the
scale of operation and steady development of corporate economic,
sincerely seeking partners, good faith cooperation and seek common
development, writing a new chapter in medical equipment field.