3.7m Length Patient Monitor Accessories 4073 Masima RD Rainbow SET MD20-12 20 Pin Cable 12 Ft. 1 / Box

Brand Name:Masima
Model Number:4073
Minimum Order Quantity:1pcs
Delivery Time:3-5 working days
Payment Terms:T/T(wire transfer), Western Union, Paypal
Packaging Details:Carton
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou Guangdong China
Address: TianHe District,GuangZhou,GuangDong
Supplier`s last login times: within 33 hours
Product Details Company Profile
Product Details

4073 Masima RD Rainbow SET MD20-12, Rainbow 20-Pin Patient Cable, 12 Ft. 1/Box


DESCRIPTION


The Rainbow SET RD Series Patient Cable is used with the RD SET® Series Sensor.

The RD Series Rainbow SET Patient Cable may only be used with devices containing Masima® SET® Technology, Masima rainbow SET® version 7.1 or later, or approved for use with Rainbow® compatible sensors. Check with individual oxygen measurement system manufacturers for compatibility with specific device and sensor models. It is the responsibility of each device manufacturer to ensure that devices are compatible with each sensor model.


Sensor functions:

• Flat sensor with smooth edges fits comfortably in the patient's hand

• Lighter than traditional cable sensors

• Quick and intuitive sensor-to-wire connection with tactile and audible feedback for proper connection

• GraPHiliphhilipic sensor guide for correct sensor application


RD SET DISPOSABLE SENSOR SERIES SPECIFICATIONS


RD SET Adt/ Pdt/ Inf/ Neo/ NeoPt/ NeoPt-500 (ARMS)

SpO2 Accuracy Range70–100%
No Motion1.5%
Motion1.5%
Low Perfusion2%

PR Accuracy

No Motion3 bpm
Motion5 bpm
Low Perfusion3 bpm

SpO2 Limits of Agreement (LoA)

Upper 95% LoA (no motion)2.3%
Lower 95% LoA (no motion)–2.3%
Upper 95% LoA (motion)2.9%
Lower 95% LoA (motion)–2.2%

WEIGHT RANGE

RD SET Adt>30 kg, finger or toe application
RD SET Pdt10–50 kg, finger or toe application
RD SET Inf3–10 kg, thumb or great toe application
RD SET Inf10–20 kg, finger or toe application
RD SET Neo (neonatal)<3 kg, hand or foot application
RD SET Neo (adult)>40 kg, finger or toe application
RD SET NeoPt<1 kg, hand or foot application
RD SET NeoPt-500<1 kg, hand or foot application

RD SET Disposable Sensor SeriesPart Number
RD SET Adt4000
RD SET Pdt4001
RD SET Inf4002
RD SET Neo4003
RD SET NeoPt4004
RD SET NeoPt-5004005
RD SET Replacement Tapes/WrapsPart Number
Replacement Tapes, Inf4046
Replacement Tapes, Neo4047
Replacement Wraps, NeoPt4048
Replacement Wraps, NeoPt-5004094

Cleaning


1. Remove the sensor from the patient and disconnect it from the patient cable.

2. Clean the cable by wiping the surface of the cable with a 70% isopropyl alcohol swab.

3. Clean all cable surfaces.

4. Dip another cloth or gauze in sterile or distilled water and wipe all electrode surfaces.

5. Wipe all surfaces with a clean cloth or dry gauze to dry the cables.


ENVIRONMENTAL

Operating Temperature41°F to 104°F (5°C to 40°C)
Storage Temperature-40°F to 158°F (-40°C to 70°C)
Relative Humidity

10% to 95% noncondensing



If you're interested in 4073 Masima RD Rainbow SET MD20-12, Rainbow 20-Pin Patient Cable, 12 Ft. 1/Box,feel free to contact us.Thank you .


China 3.7m Length Patient Monitor Accessories 4073 Masima RD Rainbow SET MD20-12 20 Pin Cable 12 Ft. 1 / Box supplier

3.7m Length Patient Monitor Accessories 4073 Masima RD Rainbow SET MD20-12 20 Pin Cable 12 Ft. 1 / Box

Inquiry Cart 0