SpO2 Board M1020-66434 For MX40 Portable Patient Monitor Medical Equipment Parts

Brand Name:Other
Model Number:M1020-66434
Minimum Order Quantity:1 Piece
Delivery Time:3-5 working days
Payment Terms:T/T, Western Union, Paypal
Price:USD
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou Guangdong China
Address: TianHe District,GuangZhou,GuangDong
Supplier`s last login times: within 33 hours
Product Details Company Profile
Product Details

SpO2 Board M1020-66434 for MX40 Portable Patient Monitor Used-good

Used-good MX40 SpO2 Board M1020-66434


► Brief Introduction


The SPO2 board (M1020-66434) in the MX40 patient monitor is a circuit board dedicated to monitoring and processing blood oxygen saturation (SpO2) data. It is responsible for receiving optical signals from external blood oxygen sensors (such as finger clip or ear clip sensors), processing the data and transmitting it to the main system. As one of the key components of the MX40 device, this board ensures accurate measurement and transmission of patient blood oxygen and pulse wave information. It uses advanced photoelectric signal acquisition and algorithms to ensure high accuracy of blood oxygen value and pulse rate data. It can perform real-time data processing and quickly respond to changes in blood oxygen and pulse rate, and is suitable for dynamic patient monitoring.


Functions

  • Signal reception: Receive optical signals from the blood oxygen sensor and record the absorption rate of red light and infrared light in the patient's body.
  • Signal processing: Calculate blood oxygen saturation value and pulse rate through algorithms.
  • Data transmission: Transmit the processed data to the main board, which further displays, records or wirelessly transmits it to the central monitoring system.
  • Support alarm function: Trigger an alarm when the patient's blood oxygen or pulse rate exceeds the safety threshold..

Precautions

  • Use original compatible blood oxygen sensors to avoid inaccurate data caused by using incompatible sensors.
  • Try to avoid patients exercising too vigorously (exercise can lead to inaccurate measurements).
  • Avoid using the device under strong light (such as surgical lights or direct sunlight) because external light sources may interfere with optical signal acquisition.
  • SPO2 boards typically require no manual calibration by the user, but the devices do require regular maintenance to ensure the data is reliable.

► Parameters


Brand:Other

Product Name:

SpO2 Board
Model:M1020-66434
Type:Spare Parts

Condition:

Used-good
Application:MX40 Portable Patient Monitor
MOQ:1 Piece

Warranty:

90 Days

Serve:

Direct Sales, Exchanges, Repairs

PAYMENT TERMS:

Pay In Full Before Shipment

► Product Picture



If you have any question about our used good MX40 SpO2 Board M1020-66434, please feel free to contact us.


In addition, our company is mainly engaged in the sale, exchange and repair of medical equipment and medical equipment accessories. If you are also interested in other medical equipment and accessories, please feel free to contact us.


After-sales issues


Our warranty time is 90 days after delivery. Before packing, we will check the goods model carefully, and if the product is in used condition, there are professional engineers who will test the functions of it. Only the test is qualified then we will pack carefully to ensure that you can receive satisfactory and workable goods. And please check the goods asap after you receiving them. If you have any questions, please feel free to contact us.


China SpO2 Board M1020-66434 For MX40 Portable Patient Monitor Medical Equipment Parts supplier

SpO2 Board M1020-66434 For MX40 Portable Patient Monitor Medical Equipment Parts

Inquiry Cart 0