Add to Cart
Osram halogen bulb 64602 12V50W optical instrument halogen bulb
It is indeed important to replace the position of the optical
instrument lamp. Regardless, it should be adjusted to be exactly
up, down, left, right, and whether the lamp holder of the bulb is
at the same height as the reflector, and the direction of the light
should not be skewed. Be sure to adjust the position of the
replaced bulb properly, otherwise imbalance and deviation may
occur.
Before replacing the light bulb, please wipe the grating with
ethanol. Before replacing the light bulb, some preparation work
should be done: place a neatly cut filter paper in the position of
the sample cell, and it should be closely attached to the position
where the transmitted light in the light path passes through to the
photovoltaic cell, so that you can see the intensity of the light.
Then adjust the whole wavelength position and record the color of
light at each specific position, especially the wavelength values
of positive red, positive blue, positive yellow, positive green and
positive purple. The purpose of observing and recording these
values is to restore them to their original state after replacing
the light bulb in the future, which indicates that there must be no
problem with the replacement.
▪ Temperature control: To avoid lens cracking and detachment caused
by thermal expansion and contraction, it is recommended to maintain
the temperature of the microscope room at 20-24 ℃.
▪ Dust prevention: Dust falling on the surface of optical
components not only affects the passage of light, but also
generates large stains after being magnified by the optical system,
which affects observation. Dust and sand particles falling into the
mechanical parts can also increase wear and tear, posing
significant hazards. Therefore, the microscope room should be kept
clean, and a dust cover should be used to cover the microscope when
not in use to prevent dust from falling off.
Moisture proof: When the air is too humid, optical lenses are prone
to mold and fogging; Mechanical parts are prone to rusting when
exposed to moisture. Normally, the microscope room should maintain
a humidity of below 65%, and dehumidifiers should be installed
indoors in humid areas.
Type: | OSRAM halogen lamp beads 64602 12V50W optical instrument halogen bulb pin rice bubble equipment bulb |
Warranty period: | 90 Days |
Shipping Date: | 3-5 Working Days |
MODLE: | 64602 12V50W |
Storage temperature: | -20-70°c |
MOQ: | 1 PCS |
COLOR: | Metal and glass |
Delivery Date: | 3 - 5 Working Days |
Package | Carton |
The company has been professionally operating various brands of original medical monitoring instruments since 2015. The company has many professional senior engineers and has sufficient ability to undertake various medical equipment maintenance work. Covering motherboards, sensors, probes, modules, connectors, shells, etc. for various medical monitoring equipment.
We default to express delivery by DHL,Fedex, We will contact you as soon as possible when sending express delivery. If you have any questions after receiving the express delivery, please feel free to contact us at any time.