Add to Cart
Features of most efficient underfloor heating air source heat pump air conditioning energy saving heat pump
A heat pump is an energy-saving device that uses high-level energy
to flow heat from a low-level heat source to a high-level heat
source. As the low-level heat source of the heat pump, air is
inexhaustible and inexhaustible. It is available everywhere and can
be obtained free of charge. Moreover, the installation and use of
air source heat pumps are relatively convenient. The research,
production, and application of air source heat pumps (also known as
air-cooled heat pumps) in my country only developed rapidly in the
late 1980s. The current products include household heat pump air
conditioners, commercial unit heat pump air conditioners and heat
pump cold and hot water units.
The air source heat pump has the following characteristics:
most efficient underfloor heating air source heat pump air
conditioning energy saving heat pump
(1) The air energy heat pump system integrates cold and heat
sources, no special refrigerating machine room or boiler room is
required, the unit can be placed on the roof or the ground
arbitrarily, and it does not occupy the effective use area of the
building, and the construction and installation are very simple.
(2) The air energy heat pump system has no cooling water system, no
cooling water consumption, and no cooling water system power
consumption. In addition, many cases of Legionella infection caused
by cooling water pollution have been reported. From the perspective
of safety and health, considering air source heat pumps also has
obvious advantages.
(3) The air-energy heat pump heating system does not require a
boiler, a corresponding boiler fuel supply system, a dust removal
system, and a flue gas discharge system, so the system is safe and
reliable, and does not pollute the environment.
(4) The air-energy heat pump cold (hot) water unit adopts a modular
design, and there is no need to set up a standby unit. The computer
automatically controls during operation to adjust the operation
status of the unit to adapt the output power to the working
environment.
(5) The performance of the air-energy heat pump will vary with
outdoor climate changes.
For further specification of Inverter 10HP 36.7 KW Split Heat Pump For Swimming Pool Use and other specifications, welcome to contact us!
most efficient underfloor heating air source heat pump air conditioning energy saving heat pump
Unit type | SJKRS-36II/C | |
Specifications | 10HP | |
Power supply | Three-phase five-wire380V/50Hz | |
Heating mode | Direct heat/cycle type | |
Standard working condition | Heating capacity( kw ) | 36.7 |
Input Power(kW) | 8.2 | |
COP | 4.5 | |
Hot Water flow(m³/h) | 0.79 | |
High temperature condition | Heating capacity kw ) | 28.5 |
Input Power(kW) | 8.9 | |
COP | 3.2 | |
Hot Water flow(m³/h) | 0.33 | |
Low temperature condition | Heating capacity( kw ) | 21.4 |
Input Power(kW) | 7.6 | |
COP | 2.8 | |
Hot Water flow(m³/h) | 0.4 | |
Component Information | Size of water pipe joint | DN20 |
Water heat exchanger | Plate or sleeve heat exchanger | |
Air Heat Exchanger | Aluminum Fin for copper tube | |
compressor type | Semi-closed reciprocating | |
Operation Panel | Color touch screen | |
Maximum outlet temperature(℃) | 90℃ | |
Refrigerants | R744 (CO2 ) | |
Design pressure(MPa) | High side 15, low side 8 | |
Dimensions (length, width and height mm) | 1600x950x1500 | |
Noise (dB) | 59 | |
Weight(kg) | 660 | |
SCOPE of use | Feed water temperature(℃) | 5~ 40 |
Feed water pressure | 0.05~ 0.4 | |
Effluent temperature(℃) | 55~ 90 | |
Maximum flow | 1.5 | |
Ambient temperature(℃) | ’-20~43 |
1) standard working conditions: ambient temperature DB 20 ° c/WB 15 ° C, using side initial water temperature 15 ° C, termination water temperature 55 ° c;
2) high temperature effluent: Ambient Temperature DB 20 ° c/WB 15 ° C, using side initial water temperature 15 ° C, termination water temperature 90 ° c;
3) low temperature working condition: ambient temperature DB-10 °C, using side initial water temperature 9 °C, termination water temperature 55 °c;
Some projects for 10HP 36.7 KW Split Heat Pump For Swimming Pool