Commercial CO2 Heat Pump Domestic 100 Degree Temperature 8kw 200kw

Brand Name:LN
Certification:CE ISO CCC ROHS
Model Number:SJKRS-05I/C
Minimum Order Quantity:Negotiable
Delivery Time:1-30 working days
Payment Terms:L/C, D/A, D/P, T/T, Western Union, MoneyGram
Contact Now

Add to Cart

Site Member
Address: PO1669, Maanshan, Anhui Province, China
Supplier`s last login times: within 44 hours
Product Details Company Profile
Product Details

CO2 heat pump temperature range domestic and commercial heat pump 8 to 200kw

Description of CO2 heat pump temperature range domestic and commercial heat pump 8 to 200kw

The upper limit of water temperature reaches 100℃;

Working limit -43°C water 100°C;

Natural refrigerant, high energy efficiency ratio (COP);

At the same time, the production of cold and hot water multi-tank heat storage and high stratification work, based on high temperature storage, the water tank capacity can be reduced, and a large amount of water can be met.

Multi-module (eight at the same time);

Safety (with 6 high-voltage safety protection, water and electricity separation);

The core control components of the unit adopt Italian Carle PLC and CPP;

The units are equipped with Italian Duling dedicated CO2 piston or Panasonic dual-rotor compressor;

The unit uses electronic expansion to achieve continuous control and expansion of refrigerant flow;

The unit has a built-in Wilo water pump and is controlled by frequency conversion to obtain high-precision outlet water temperature;

The casing of the unit is made of galvanized sheet and sprayed, the water receiving tray and the water inlet and outlet of the unit are made of 304 stainless steel, and the added aluminum filter screen effectively protects the heat exchange efficiency of the evaporator.

application range /
CO2 heat pumps are the ideal solution for installations with high temperature hot water needs

Ideal place to use:

Hotels / Restaurants / Factory and School Canteens / Residential and Tourist Buildings / Sports Centers

Hospitals / Industrial Food Sterilization / Dry Cleaners and Textile Manufacturing / Cement Manufacturing / Wherever hot water is needed
The frequency can be automatically changed in real time to achieve the most efficient operation (the most efficient production of hot water)

The unit operates independently in summer (to meet the efficient operation of the heat exchanger)

In heating conditions, it can be controlled by itself according to the heat load (to achieve efficient heating at -30 degrees)

When the unit has high temperature and high pressure, the unit is self-variable (safer)

In summer, the fan reduces energy consumption by itself (the fan can save energy by 50%)

Reduced grid impact through variable frequency drive, extended compressor life (durable)
Dedicated algorithm for maximum COP
With the COP automatic tracking system, the alternatives on the market are unmatched.

The parameters can be automatically changed in real time to achieve the most efficient operation.

When the working conditions are changed, the variable flow through the electronic expansion valve.

Management control, which effectively ensures the maximization of cop.

【safe and stable】
The core control components are original from Italy, Japan and Germany
Human interface, intelligent cloud service, remote management

The unit operating parameters and fault information are uploaded to the client or intelligent cloud service system in real time;

Separation of water and electricity, constant water temperature, non-toxic and non-flammable working fluid;

The refrigeration system is designed with 6 high-voltage protection devices;

Compressor and water pump are controlled by frequency conversion.
【Low temperature operation】
Intelligent frost and antifreeze to break the low temperature limit

Work safely and stably in the environment of -30°C-43°C, and continuously provide 90°C hot water to break the "boundary" of use

Intelligent detection of defrosting requirements, frequency conversion control can save 50% energy than traditional or other similar products;

Professional frequency conversion incremental control to meet the requirements of different water consumption in different environments
【Energy saving and environmental protection】
Real-time automatic parameter conversion (frequency conversion), to achieve the most efficient operation (COP=4.8), natural products

Non-flammable, non-flammable, natural product, good compatibility, low cost; no need to re-acquire;

ODP = 0 (Ozone Threat Potential 0) GWP = 1 (Greenhouse Potential 1);

not be bound by any country's tax and regulatory regulations;

With COP automatic tracking system, it can automatically change parameters in real time to achieve the most efficient operation;

The intelligent variable frequency control of the compressor pump and the variable flow management control of the electronic expansion valve effectively ensure the maximization of COP.
Hot water]
Maximum water temperature up to 98°C Ideal for industrial applications

The water temperature is as high as 98°C, and the water temperature is much higher in efficiency and temperature than traditional HFC refrigerants for heat pumps;

The high-temperature hot water at 95°C can be produced, and the thermal efficiency is 2.5 times higher than that of traditional electric heating;

Such high temperature water effectively prevents the formation of Roman legions.

Installation Notes:
1. The spacing around the installation must not be less than Im;
2. The pipelines other than the heat pump should be protected from frost and heating elements can be installed;
3. Heat insulation and protection measures should be taken for the pipelines for hot water circulation to prevent heat loss.

HPA/mmB/mmC/mm
7.514509501450
1016009501500
15185011501900
20205011501950
30267014102150
40229022701980

Application Diagram Pressure-bearing water tank

CO2 heat pump temperature range domestic and commercial heat pump 8 to 200kw

System Diagram Smart Control System

CO2 heat pump temperature range domestic and commercial heat pump 8 to 200kw


CO2 heat pump hot water unit specification list

CO2 heat pump temperature range domestic and commercial heat pump 8 to 200kw

ModelSJKRS-05I/CSJKRS-28II/CSJKRS-36II/CSJKRS-55II/CSJKRS-73II/CSJKRS-106II/CSJKRS-160II/C
Specification2HP7.5HP10HP15HP20HP30HP45HP
Power supply230V/1N/50Hz380V/3N/50Hz
Heating MethodDirect heating / circulating
Nominal working condition( kw)heating capacity7.4528.137.756.174.1108.6158.7
( kw)
Input power
1.616.18.212.216.123.634.5
COP4.64.64.64.64.64.64.6
( m³/h)
Heating water flow
0.110.60.811.211.622.333.41
High temperature working conditions(kw)heating capacity5.5823.928.551.559.589131.5
( kw)Input power1.737.58.916.118.627.841.1
COP3.23.23.23.23.23.23.2
( m³/h)
Heating water flow
0.070.270.330.590.681.021.51
Low temperature working conditions(kw)heating capacity4.315.719.131.838.959.390
( kw)Input power1.595.87.111.814.421.933.3
COP2.72.72.72.72.72.72.7
(m³/h)
Heating water flow
0.070.280.340.560.681.041.52
Parts informationWater pipe interface sizeDN15DN20DN25DN32
Water heat exchangerPlate or tube heat exchanger
Air heat exchangerCopper tube aluminum fins
Compressor typeDouble rotarySemi-closed reciprocating type
Operation panelColor touch screen
Maximum outlet temperature85℃90℃
RefrigerantR744(CO2)
Design pressur(MPa)15MPa(HP)/8MPa(LP)
Dimensions (L,W,H mm)750*390*12451450*950*14501600*950*15001850*1150*19002050*1150*19502670*1410*21502070x2150x2245
( dB) Noise≤44≤56≤59≤62≤67≤70≤70
( kg) Weight8355066078086011801360
Feedwatertemperature(℃)5~40
( Feed water pressure MPa)0.05~0.4
Water Outlet temperature (℃)55~8555~90
Maximum flow0.241.21.52.43.24.96.5
Ambient temperature (℃)-25~43

System schematic diagram



China Commercial CO2 Heat Pump Domestic 100 Degree Temperature 8kw 200kw supplier

Commercial CO2 Heat Pump Domestic 100 Degree Temperature 8kw 200kw