OMRON 200V 900W R88M-G90010T-B-Z AC Servo Motor refer to
MECHATROLINK-II Status LED Indicator
Servo Drive Functions
Display Area
A 2-digit 7-segment LED display shows the Servo Drive status, alarm
codes, parameters, and other information.
Analog Monitor Check Pins (SP, IM, and G)
The actual motor speed, command speed, torque, and number of
accumulated pulses can be measured based on the analog voltage
level by using an oscilloscope.
Set the type of signal to be output and the output voltage level by
setting the Speed Monitor (SP)
Selection (Pn007) and Torque Monitor (IM) Selection (Pn008).
For details, refer to User Parameters .
MECHATROLINK-II Status LED Indicator Indicates
the communications status of the MECHATROLINK-II.
For details, refer to MECHATROLINK-II Status LED Indicator
Rotary Switches
Sets the node address.
For details, refer to Servo Drive Display and Settings
The following OMNUC G-Series AC Servomotors are available.
3,000-r/min Servomotors
3,000-r/min Flat Servomotors
2,000-r/min Servomotors
1,000-r/min Servomotors
There are various options available on the Servomotors, such as
models with brakes, decelerators, or different shaft types. Select
a Servomotor based on the mechanical system’s load conditions and
the installation environment.
*1. These are the values when the Servomotor is combined with a
Servo Drive at room temperature (20°C, 65%). The maximum momentary
torque indicates the standard value.
*2. Applicable Load Inertia The operable load inertia ratio (load
inertia/rotor inertia) depends on the mechanical configuration and
its rigidity. For a machine with high rigidity, operation is
possible even with high load inertia. Select an appropriate motor
and confirm that operation is possible. If the dynamic brake is
activated frequently with high load inertia, the dynamic brake
resistor may burn. Do not repeatedly turn the Servomotor ON and OFF
while the dynamic brake is enabled.
*3. The allowable radial and thrust loads are the values determined
for a service life of 20,000 hours at normal operating
temperatures. The allowable radial loads are applied as shown in
the following diagram.
*4. This is an OFF brake. (It is reset when excitation voltage is
applied).
*5. The operation time is the value (reference value) measured with
a surge suppressor (CR50500 manufactured by Okaya Electric
Industries Co., Ltd.).
R88M-GP10030L-S2 | R88M-GP20030L-S2 |
R88M-GP10030H-S2-Z | R88M-GP20030H-S2-Z |
R88M-GP40030H-S2-Z | R88M-GP10030L-BS2 |
R88M-GP20030L-BS2 | R88M-GP10030H-BS2-Z |
R88M-GP20030H-BS2-Z | R88M-GP40030H-BS2-Z |
R88D-GTA5L | R88D-GT01L |
R88D-GT02L | R88D-GT04L |
R88D-GT01H-Z | R88D-GT02H-Z |
R88D-GT04H-Z | R88D-GT08H-Z |
R88D-GT10H-Z | R88D-GT15H-Z |
R88D-GT20H-Z | R88D-GT30H-Z |
R88D-GT50H-Z | R88D-GT75H-Z |
R88M-G05030H-Z | R88M-G10030L |
R88M-G20030L | R88M-G40030L |
R88M-G05030H-Z | R88M-G10030H-Z |
R88M-G20030H-Z | R88M-G40030H-Z |
R88M-G75030H-Z | R88M-G05030H-B-Z |
R88M-G10030L-B | R88M-G20030L-B |
R88M-G40030L-B | R88M-G05030H-B-Z |
R88M-G10030H-B-Z | R88M-G20030H-B-Z |