Stable operation Brushless Motor Serum separation High Speed
Refrigerated Centrifuge
High Speed Refrigerated Centrifuge Features:
1. Microprocessor control, operated by touch panel, LED digital
display for speed, time and RCF. Operated data can be saved
automatically, RCF value can be set directly for working, easy to
use.
2. Brushless converter motor which has high torque, High speed
bearing from Europe, smoothly running and maintenance-free.
3. Multistage damping system, the freon-free compressor from
Europe, low noise and slight vibration, green.
Steel body, stainless steel chamber which electrostatic powder
coated. Imports of key components, durable and easy to clean.
4. Over-speed, door interlock and electronic lock lid for safe
operation unbalanced protection. The rotor can be disinfected at
high temperature & high pressure, ensure safety.
5. Proprietary air current design, small temperature-rise of
centrifuge chamber, effective protection of the sample.
6. The brushless direct drive motor without pollution
Electronic lock lid for safe operation
7. Adapted to a variety of rotors.
Max RCF | 23610×g |
Max Speed | 18500r/min |
Max Capacity | 4×100mL |
Timer Range | 0-99h59min |
Temp control range | -20℃~40℃ |
Noise level | ≤60dB(A) |
Power supply | AC220V 50Hz |
Stable operation Brushless Motor Serum separation High Speed
Refrigerated Centrifuge Operating procedures:
1. The working table of the desktop high-speed centrifuge should be
flat and firm, and the working room should be neat and clean, dry
and well ventilated.
2. Turn on the power switch and the instruction light is on.
3. Turn off the power switch.
4. Open the centrifuge cover and wipe the inner cavity and rotor
clean.
5. Install test tubes with consistent weighing.
6. Close the centrifuge lid.
7. Set the timing.
8. Turn on the power switch.
Stable operation Brushless Motor Serum separation High Speed
Refrigerated Centrifuge Precautions:
1. The table on which the centrifuge is placed should be solid and
flat. All four rubber feet should be in contact with the table and
be evenly stressed to avoid vibration.
2. The power supply must have a grounding wire to ensure that the
centrifuge is effectively grounded through the power socket.
3. Do not move the centrifuge when it is running. No items can be
placed on the door cover to prevent damage to the items on the door
cover when the door cover opens automatically.
4. The centrifugal tube is filled with liquid as evenly as
possible. If the difference of the liquid is too large, large
vibration will be generated during operation. At this time, the
machine should be shut down and checked to make the filling meet
the requirements. The centrifugal tube must be placed in an even
number and symmetrically.
5. If the centrifugal test tube ruptures during operation, it will
cause greater vibration, so it should be shut down immediately.