Multiple languages can be set Heating defrost High Speed
Refrigerated Centrifuge
High Speed Refrigerated Centrifuge Features:
* High speed refrigerated centrifuge use more stable and reliable
micro-motor electronic lock;
* High speed refrigerated centrifuge adopt two-stage shock
absorption system structure and imported motor to enhance
instrument stability and reduce noise;
* The unique waterproof design of the motor is used to improve the
service life of the motor;
* High speed refrigerated centrifuge imported compressor
(fluorine-free environmentally friendly refrigerant) is used, with
high stability, long service life and rapid
cooling;
* The centrifugal chamber is treated with a special process to have
good corrosion resistance, durable and more beautiful
* Adopts micro brushless motor, free-maintenance, no powder
pollution, micro-computer control, LCD displays the
time and speed.
* Electric lid lock, easy and reliable.
* Over-speed and imbalance protection.
Max RCF | 27600×g |
Max Speed | 20000r/min |
Max Capacity | 6×50ML |
Standard rotor | 12×1.5/2.0ML |
Temp control range | -20℃~40℃ |
Noise level | ≤60dB(A) |
Power supply | AC220V 50Hz |
Multiple languages can be set Heating defrost High Speed
Refrigerated Centrifuge Maintenance
1. Do not place any material on the centrifuge cover. After each
use, be sure to clean the inner cavity and rotor.
2. If the desktop high-speed centrifuge has not been used for a
long time, the centrifuge cover should be opened for a period of
time before use to dry the inner cavity.
3. The wear and tear of the desktop high-speed centrifuge after
long-term use is normal.
4. The workbench and casing should be kept clean at all times, and
the centrifuge should be covered with a plastic cover when not in
use, and stored in a dry air room without harmful gas immersion.
How to operate the high-speed centrifuge correctly
The operation method of the high-speed centrifuge is very
important. Only by better understanding the relevant operating
knowledge or operating specifications, can we avoid some
unnecessary failures such as excessive vibration or abnormal
rotation of the motor. During the operation Among them, we must
first ensure that the work surface is flat and firm, the work room
should be neat and clean, and well ventilated and dry, so as to
effectively avoid excessive vibration, and the area must be turned
off for testing before use. Then you can turn on the power to see
if the power is on or the indicator light is on. In addition, turn
off the power, open the lid, wipe the inner tube or rotor clean,
put a certain amount of test tube, turn off the centrifuge tube,
and then set the timing. Turn on the power switch to adjust the
speed.
Regarding the setting of the speed, the requirements of the speed
of different separated samples will also be different. We can set
the speed according to our own actual needs, and the speed must be
adjusted to the minimum position before each shutdown, and then the
timer is reset Then turn off the power switch, but also need
regular cleaning or maintenance work.