Add to Cart
The U401 board supports the mixed transmission of OTN, SDH and packet services. It supports Layer 2 switching, MPLS-TP, and OTN interfaces.
The U401 board can work in either line mode or relay mode. The board supports ODUk, packet services and VC-4 services only when it works in line mode.
Board Mode | Input signal | Basic function | More information |
---|---|---|---|
Line Mode | OTN | 80xODU0/40xODU1/10xODU2/ 10xODU2e/2xODU3/1xODU4/ 80xODUflex<->1xOTU4 | Table 2 |
SDH NOTE: Only the TNU3U401 , TNU4U401 board supports the SDH service. |
| Table 3 | |
Packets | A maximum of 100 Gbit/s packets <-> 80 x ODU0/40 x ODU1/10 x ODU2/2 x ODU3/1 x ODU4/80 x ODUflex <-> 1 x OTU4 | Table 4 | |
Relay mode | - | OTU4<->OTU4 | Table 5 |
Function and Feature | Description | ||||||
---|---|---|---|---|---|---|---|
OTN functions |
| ||||||
WDM specification | Supports ITU-T G.694.1-compliant DWDM specifications. | ||||||
Tunable wavelength function | Supports tunable wavelength optical modules that provide for 80 wavelengths tunable in the C band with 50 GHz channel spacing. TNU4U401 Supports tunable wavelength optical modules that provide for 96 wavelengths tunable in the extended C band with 50 GHz channel spacing. | ||||||
PRBS test function | Supports the PRBS function on the WDM side. | ||||||
FEC coding | TNU2U401/TNU3U401: Supports SDFEC2 on the WDM side. TNV2U401: Supports HFEC on the WDM side. TNU4U401: Supports SDFEC2 and HFEC PLUS encoding. NOTE: Boards that use different FEC modes cannot interconnect with each
other. | ||||||
Alarms and performance events monitoring |
| ||||||
Regeneration board | The WDM-side signals from an U401 board can be regenerated by another U401, N401, N402, LTX board or an NS4 board of the same type. For example,
| ||||||
ALS function | Not supported | ||||||
Test frame | Not supported | ||||||
Physical clock | Supported (ODU0/ODU1/ODU2/ODU2e/ODU3/ODUflex) | ||||||
IEEE 1588v2 | Supported NOTE: The TNU3U401 boards have the following restriction:
| ||||||
ITU-T G.8275.1 | Only the TNU4U401 board supports. | ||||||
Electrical-layer ASON | Supported | ||||||
Optical-layer ASON | Supported | ||||||
Protection schemes |
NOTE: When the cross-connect granularity is ODUflex, the board does not
support tributary SNCP protection. ODUk SNCP protection and tributary SNCP are not supported when packet services are cross-connected from the backplane. | ||||||
Loopback | WDM-Side Loopback | Channel Loopback | |||||
Supported | ODUk (k = 0, 1, 2, 2e, flex, or 3) channel loopbacks | ||||||
ESC | Supported |
Function and feature | Description | ||||||
---|---|---|---|---|---|---|---|
Overhead processing |
| ||||||
Protection schemes |
| ||||||
Alarms and performance events monitoring |
| ||||||
Service processing | Supports the VC-12/VC-3 services, VC-4 services, VC-4-4c
concatenation services, VC-4-16c concatenation services, and
VC-4-64c concatenation services. NOTE: To support VC-12 and VC-3 service granularities, the lower-order
cross-connect board SXCL must be used. | ||||||
Loopback | Supports VC4 loopbacks. Supports virtual port loopbacks. | ||||||
SDH clock | Supported | ||||||
IEEE 1588v2 | Not supported | ||||||
Outband DCN | TNU4U401: Supported Other boards: Not supported | ||||||
SDH ASON | supported NOTE: The TNU3U401 boards have the following restriction:
|
Function | Description | ||
---|---|---|---|
QoS | Diffserv | Supported, compliant with RFC 2474 and RFC 2475 | |
Traffic classification |
| ||
Traffic policing | Committed access rate (CAR), two rate three color marker (trTCM) compliant with RFC 2698 | ||
Congestion management | Class of service (CoS), supporting SP/WFQ scheduling algorithms | ||
Congestion avoidance | WRED, tail dropping | ||
Traffic shaping | Port-based traffic shaping, queue-based traffic shaping | ||
HQoS | Supports service PW polices, tunnel rate limiting, V-UNI egress policies. | ||
Protection schemes |
| ||
Packet services have the capability of surviving against multiple fiber cuts | Supported | ||
IGMP Snooping V1/V2/V3 | Supported | ||
Maintenance | Ethernet service OAM | Supported, compliant with IEEE 802.1ag, ITU-T Y.1731/ITU-T G.8013 and ITU-T Y.1730 | |
Ethernet port OAM | Not supported | ||
MPLS-TP OAM | Supported, compliant with ITU-T G.8113.1 | ||
MPLS OAM | Supported, compliant with ITU-T Y.1711, ITU-T Y.1561. | ||
RMON | Supported | ||
Port mirroring | Supported | ||
Loopback | MAC Loopback | Not supported | |
PHY Loopback | Not supported | ||
Synchronous Ethernet | Not supported | ||
IEEE 1588v2 | Not supported | ||
Inband DCN | Supported | ||
Ethernet data frame format | IEEE 802.3, Ethernet II, IEEE 802.1q, IEEE 802.1p | ||
MTU | 9600 bytes. | ||
Flow control at ports | Not supported | ||
LPT function | Supported | ||
Service type | E-Line (VPWS), E-LAN (VPLS) | ||
Service bearing medium | Port, PW, QinQ | ||
QinQ | Supports basic QinQ and flexible QinQ. | ||
E-Line | PW-based service models | Port<->PW | |
CVLAN<->PW | |||
SVLAN<->PW | |||
PW<->PW (MS-PW) | |||
Port-based service models | Port<->Port | ||
CVLAN<->Port | |||
SVLAN<->Port | |||
UNI-UNI service models | Port<->Port | ||
CVLAN<->CVLAN, VLAN translation supported | |||
SVLAN<->SVLAN, VLAN translation supported | |||
E-LAN | Bridge type | IEEE 802.1d, IEEE 802.1q, IEEE 802.1ad | |
Bridge learning mode | SVL, IVL | ||
VSI tag type | C-Aware, S-Aware, T-Aware |
Function and Feature | Description | ||
---|---|---|---|
Basic function | Electrically regenerates optical signals at an electrical REG station. | ||
Supported service rate | OTU4: OTN service at a rate of 111.81 Gbit/s | ||
OTN function |
| ||
WDM specification | Supports ITU-T G.694.1-compliant DWDM specifications. | ||
Tunable wavelength function | Supports tunable wavelength optical modules that provide for 80 wavelengths tunable in the C band with 50 GHz channel spacing. TNU4U401 Supports tunable wavelength optical modules that provide for 96 wavelengths tunable in the extended C band with 50 GHz channel spacing. | ||
ESC function | Supported | ||
PRBS function | Not supported | ||
FEC coding | TNU2U401/TNU3U401:Supports SDFEC2 on the WDM side. TNV2U401:Supports HFEC on the WDM side. TNU4U401: Supports SDFEC2 and HFEC PLUS encoding NOTE: Boards that use different FEC modes cannot interconnect with each
other. | ||
Alarms and performance events monitoring |
| ||
ALS function | Not supported | ||
Test frame | Not supported | ||
Physical clock | Not supported | ||
IEEE 1588v2 | Not supported | ||
Electrical-layer ASON | Not supported | ||
Optical-layer ASON | Supported | ||
Protection scheme | Not supported | ||
Loopback | Not supported |
Board | WDM-Side Optical Module | Typical Power Consumption (W) | Maximum Power Consumptiona (W) |
---|---|---|---|
TNU2U401 | 150000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2)-PIN 55000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2)-PIN 40000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2)-PIN 150000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2,wDCM)-PIN 12000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2,wDCM)-PIN | 298 | 311 |
TNU3U401 | 150000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2, Enhanced)-PIN 150000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2)-PIN 55000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2)-PIN 40000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2)-PIN 150000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2,wDCM)-PIN 12000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2,wDCM)-PIN 120000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2)-PIN 120000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2,wDCM)-PIN | 254 | 270 |
TNV2U401 | 40000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(HFEC)-PIN | 268 | 281 |
TNU4U401 | 40000ps/nm-Extended C band-Tunable Wavelength-ePDM-QPSK (SDFEC2, ULH+, T5U)-100G CFP 40000ps/nm-Extended C band-Tunable Wavelength-ePDM-QPSK (SDFEC2, wDCM, LH, T62)-100G CFP 12000ps/nm-Extended C band-Tunable Wavelength-ePDM-QPSK (SDFEC2, wDCM, Metro, T65)-100G CFP 40000ps/nm-Extended C band-Tunable Wavelength-ePDM-QPSK (configurable FEC, coherent/wDCM, ULH+, TxA)-100G CFP | 265 | 272 |
a: The maximum power consumption is the power consumed by the board when it works normally under the highest ambient temperature. |
Delivery Options | Estimated Delivery Time |
---|---|
DHL | 3-5 business days |
Fedex | 3-5 business days |
By Sea | 10-20 business days |
Notice:
Above mentioned information are just for your reference only,we will keep you posted for the tracking delivery schedule.There are two delivery options available for by air and by sea:
Deliver to port:
Uonel is responsible for transporting goods to port. All subsequent
customs and transportation fees are the
responsibility of the buyer. Uonel will recommend trustworthy local
freight forwarders to you.Uonel can facilitate the progress under
buyer's permission and at buyer's expense.
Deliver to door:
Uonel will quote all destination charge prior once we have
confirmed order.
Uonel is responsible for transporting goods to door after you have
made the payment.
100% Low Price Guarantee:
Uonel provides high-quality products at low wholesale prices
100% Quality Assurance:
All items are ORIGINAL NEW and GENUINE only.
Free Technical Support:
Our FREE Expert Consultancy Support is over the phone, by chat, by email or by login remotely.
100% Money Back Guarantee:
You can contact our customer service team to exchange or return any
product that you bought from us.
Flexible Secure Payment & Shipment:
Verified authorization: Mcafee Secure, VeriSign Secured
Return Material Authorization (RMA) Process
Standard Hardware Warranty Policy:
Original new sealed product: 1 Year
The Support Contacts:
If your products failed, you must contact your sales representative to verify product failure. If the problem still can't correct by remote support methods i.e. email or phone support, the RMA procedure will issue.
Uonel is one of the biggest Network Hardware distributor in china, founded in 2008. We are a global provider of netwotking products with more than 5000 customers.
We provide original new Routers,Switches,Firewalls,Wireless APs & controllers,OLTs,GPON modems,optical transceivers.Our company have more than $5million products in stock.
Most of our technical engineers had work exprience in company,we can provide network design&planning,configration,troubleshooting,maintenance and training service in world wide.