Micro Motion F100S Coriolis Meter, 316L Stainless Steel F100S128CCAZEZZZZ


Part Number: F100S128CCAZEZZZZ
Product Name: Micro Motion F100S Coriolis Meter
Origin: USA
Manufacturer: Micro Motion

SPECIFICATIONS :

Micro Motion F100S Coriolis Meter, 1 Inch (DN25), 316L Stainless Steel

MASS FLOW ACCURACY - (Liquid)±0.20% of rate (standard)±0.15% of rate (optional)±0.10% of rate (optional)
MASS FLOW REPEATABILITY - (Liquid)±0.050% of rate
VOLUME CONTROL ACCURACY - (Liquid)±0.28% of rate (standard)±0.25% of rate (optional)±0.15% of rate (optional)
VOLUME CONTROL REPEATABILITY - (Liquid)±0.050% of rate
MASS FLOW ACCURACY - (Gas)±0.5% of rate
MASS Flow REPEATABILITY - (Gas)
±0.25% of rate
DENSITY ACCURACY - (Liquid)
±0.002 g/cm³ (2.0 kg/m³) (standard)±0.001 g/cm³ (1.0 kg/m³) (optional)
TEMPERATURE ACCURACY -±1 °C ±0.5% of reading
SENSOR Maximum WORKING PRESSURE -1,450 psig (100 barg)
METER APPROVALS, CALIBRATIONS, & CERTIFICATIONS-

•UL
•CSA
•IECEx
•NEPSI
•ATEX
•Ingress Protection
•EMC effects


Micro Motion 2700 Field And Integral-Mount Multivariable Flow And Density Transmitter

OUTPUT VARIABLES -
Mass & volume flow
Net product content / flow
Temperature
Density
Concentration
LOCAL DISPLAY -
Standard user interface with 2-line LCD panel
Two optical switches for local operation
Glass or plastic lens options


POWER-
Self-switching AC/DC input, automatically recognizes supply voltage
85 to 265 VAC, 50/60 Hz, 6 watts typical, 11 watts maximum
18 to 100 VDC, 6 watts typical, 11 watts maximum
Complies with low voltage directive 2006/95/EC per EN 61010-1 (IEC 61010-1) with amendment 2, and Installation (Overvoltage) Category II, Pollution Degree 2
INPUT /OUTPUT SIGNALS - (analog output option)
Not intrinsically safe
One active 4–20 mA output
One active frequencty output
Frequency output can be configured as a discrete output
INPUT /OUTPUT SIGNALS - (configurable I/O option)


Not intrinsically safe
One or two active 4–20 mA outputs
One or two active/passive frequency outputs
One or two active/passive discrete outputs
One discrete input
INPUT /OUTPUT SIGNALS - (intrinsically safe option) Intrinsically safe
One passive 4–20 mA output
One passive frequency output
Frequency output can be configured as a discrete output
INPUT /OUTPUT SIGNALS -(Foundation fieldbus option)
Intrinsically safe (or optionally non-incendive)
One Foundation fieldbus H1 output
INPUT /OUTPUT SIGNALS -(PROFIBUS-PA option)


Intrinsically safe
One PROFIBUS-PA output
HART/WIRELESSHART-
Bell 202 signal is superimposed on the primary milliamp output
WIRELESS -
HART available via THUM adapter
HART communication is unavailable on Foundation fieldbus and PROFIBUS-PA transmitter versions


MOUNTING OPTIONS -
Field-mount
•Integrally mounted to a Micro Motion F-Series, R-Series, or H-Series sensor
•Remotely mounted to any 4-wire or 9-wire Micro Motion Coriolis sensor


APPLICATION TYPES-
Continuous process control
Custody transfer
Two-phase flow/entrained gas
Meter verification
SIS Certified
HAZARDOUS APPROVALS -
Class I, Div. 1
Class I, Div. 2
Zone 1
Zone 2


Common Models:


2700C12ABUEZZZCMF300H999NAFZEZZX
2700I13EFZEZAZCMF100M328NHGZEZZZ
2700I13DEZEZZZCMF050M313NHGZEZZZ
2700R11EBFEZAZCMF200M418NABZEZZZ
2700I11EBMEZAZCMF300M355N2BZEZZZ
2700I11EBFEZAZCMF300M426N3FZEZZZ
2700R11EFZEZZZF025S113CABZEZZZZ
8705THA140S1W0NDB3R025S113NCAZEZZZZ
8732EST2A2NDR100S128NCAZEZZZZ
8732EST2A2EDR100S128NQFZEZZZZ
8711SSA040R1N0R050S113NCAZEZZZZ
8712ESR1A1N0M4R200S418NCANEZZZZ
8712ESR1A2N0M4F200S418CCAMEZZZZ
8711SSA030R1N0F200S418CABZEZZZZ