Quick Detail of DETECTOR INTERFACE


Number of channels:One
Location of switch:
Zone 0, IIC, T6 hazardous area
Div.1, Group A, hazardous location
Location of proximity detector
Zone 0, IIC, T4–6 hazardous area, if suitably certified
Div.1, Group A, hazardous location
Hazardous–area inputs:
Inputs conforming to BS EN60947–5–6:2001 standards for
proximity detectors (NAMUR)

Description of DETECTOR INTERFACE


The MTL5514-T enables a safe–area load to be controlled, through a relay, by a proximity detector or switch located in a hazardous area. Line faults are signalled through a separate relay and indicated on the top of the module. Switches are provided to select phase reversal and to enable the line fault detection.

Specification of DETECTOR INTERFACE


Number of channelsOne
Location of switchZone 0, IIC, T6 hazardous area
Div.1, Group A, hazardous location
Location of proximity detector
Zone 0, IIC, T4–6 hazardous area, if suitably certified
Div.1, Group A, hazardous location
Hazardous–area inputsInputs conforming to BS EN60947–5–6:2001 standards for
proximity detectors (NAMUR)
Voltage applied to sensor7 to 9V dc from 1kΩ ±10%
Input/output characteristicsNormal phase
Outputs closed if input > 2.1mA (< 2kΩ in input circuit)
Outputs open if input < 1.2mA (> 10kΩ in input circuit)
Hysteresis: 200µA (650Ω) nominal
Line fault detection (LFD) (when selected)
User-selectable via switches on the side of the unit. Line faults
are indicated by an LED. Line fault relay is energised and channel
output relay de-energised if input line-fault detected
Open-circuit alarm on if Iin < 50µA
Open-circuit alarm off if Iin > 250µA
Short-circuit alarm on if Rin < 100Ω
Short-circuit alarm off if Rin > 360Ω
Note: Resistors must be fitted when using the LFD facility with a contact input
500Ω to 1kΩ in series with switch
20kΩ to 25kΩ in parallel with switch
Safe-area output
Channel: Single pole relay with changeover contacts
LFD: Single pole relay with changeover contacts
Note: reactive loads must be adequately suppressed

Feature of DETECTOR INTERFACE


·1-channel,
·line fault detection,
·phase reversal



Advantage of Our Team


Best possible prices and delivery time
Long time experience in the field
Well trained staff
Own warehouse facilities
Best relationships with branch office of manufacture
Flexible and individual service for you
Cheap and safe forwarder for shipments (air)

Frequently Asked Questions:


Q: Does your goods are new and original?
A: Yes, they are new and original.

Q: How long warranty?
A: One-year warranty.

Q: Does any certificates can be provided?
A: Yes, it depends on what product you request, please check details with us.



































China MTL5514 Switch / Proximity Detector Interface Normal Phase supplier

MTL5514 Switch / Proximity Detector Interface Normal Phase

Inquiry Cart 0