Red Wet Type Fire Hydrant Type A182 F22 Water Globe Valve 2 Way Pedestal With Control Outlet

Brand Name:TOBO
Certification:API ISO CE
Model Number:SS304
Minimum Order Quantity:5Pcs
Delivery Time:10 working days
Payment Terms:L/C, T/T, Western Union
Contact Now

Add to Cart

Verified Supplier
Location: Shanghai Shanghai China
Address: No.208,Lvdi Road,Baihe Town,Qingpu District,Shanghai,China
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

Red Wet Type Fire Hydrant Type A182 F22 Water Globe Valve 2 Way Pedestal With Control Outlet


Standard Material Specifications

NO.Part NameCS to ASTMAS to ASTMSS to ASTM
Type A105Type A182 F22Type F34(L)Type F316(L)
1BodyA105A182 F22A182 F304(L)A182 F316(L)
2DiscA276 420A276 304A276 304(L)A276 316(L)
3StemA182 F6A182 f304A182 F304(L)A182 F316(L)
4Pressure SeatA105A182 F304A182 F304(L)A182 F316(L)
5Pressure RingA182 F304(L)F316L
6BonnetA105A182 F22A182 F304(L)A182 F316(L)
7PinA276 420A276 304
8P.S.WasherA105A182 F22A182 F304(L)A182 F316(L)
9P.S.Lock NutA194 2HA194 4A194 8A194 8M
10Stem PackingFlexible GraphitePTFE
11GlandA276 420A182 F304
12Gland FlangeA216 WCBA351 CF8
13Gland EyeboltA193 B7A193 B16A193 B8A193 B8M
14Gland NutA194 2HA194 4A194 8A194 8M
15Yoke NutA276 410
16HandwheelA197
17NameplateSS
18H.W.NutA194 2HA194 4A194 8A194 8M
Suitable MediumW.O.G.etcW.O.G.etcHNO3,CH3OOH etc
Suitable Temperature-29 425-29 550-29 180
Note: Other materials are available upon request.

imensions (mm) and Weights (Kg)
NPS1/23/411-1/41-1/22
L(RTJ)900Lb 1500Lb216229254279305368
2500Lb264273308349384451
H(OPEN)900Lb 1500Lb318318318398408524
2500Lb333333333410420524
W160160180200250280
Weights900Lb 1500Lb15.516.918.928.934.352.8
2500Lb18.020.523.036.145.081.5

Globe valves are extensively employed to control flow. The range of flow control, pressure drop, and duty must be

considered in the design of the valve to avert premature failure and to assure satisfactory service. Valves subjected

to high-differential pressure-throttling service require specially designed valve trim.


Generally the maximum differential pressure across the valve disc should not exceed 20 percent of the maximum

upstream pressure or 200 psi (1380 kPa), whichever is less. Valves with special trim may be designed for applications

exceeding these differential pressure limits.


Advantages and disadvantages of Globe valves


ADVANTAGES:

  • Good shutoff capability
  • Moderate to good throttling capability
  • Shorter stroke (compared to a gate valve)
  • Available in tee, wye, and angle patterns, each offering unique capabilities
  • Easy to machine or resurface the seats
  • With disc not attached to the stem, valve can be used as a stop-check valve

DISADVANTAGES:

  • Higher pressure drop (compared to a gate valve)
  • Requires greater force or a larger actuator to seat the valve (with pressure under the seat)
  • Throttling flow under the seat and shutoff flow over the seat

Packing Details:


We choose suitable wood cases according to different valves and arrange skilled workers to pack in case of bruise. Long term cooperated forwarder will book space, clear customs and transport for us without delay. There are three ways for transportation, by sea, by air and by train. We will arrange transportation according to customers' needs.

Delivery Details: According to the order, 7~60days


Detailed Product Description
Product Name:HydraulicApplication:Water
Size:DN100Pressure:PN16
Standard:GBTemperature:-4~80 C
Body:Cast IronColor:Red
High Light:

cast steel globe valve

,

water globe valve


Red Wet Type Fire Hydrant 4" Water Globe Valve 2 Way Pedestal With Control Outlet


body Material: ductile iron
bonnet: cast iron
DN100 flange end
surface painting


ParametersProduction Description
Hydrant type:Underground
Installation positionVertical
Installation location

Underground, area of heightened dampness,

water, use of anti-icing liquids

Labelling

The hydrant should have plaque with following contents;

name and trademark of manufacturer, Standard,

Height of hydrant, production year.

Instructions

Instruction manual in Russian,

Technical sheet (passport) in Russian.

Documents to be kept in air-tight bag.

Delivery

Hydrant to be packaged and delivered in assembled state.

Valve to be in closed position.

Certification

Manufacturer to have ISO 9001 certification.

Regular testing at place of manufacturer.

WarrantyMinimum 36 months from date of dispatch from factory
Но.DescriptionParameter
1

Working pressure, kgc/cm2,

no more than

16
2

Height of hydrant, mm

(with interval every 250mm)

500-3500
3Material of main body of hydrantcaste iron not less than СЧ15

malleable caste iron not less than EN-GJS-400-15 in accordance

with DIN EN 1563

hot dip galvanized steel on all sides + external

two-component PU covering

(epoxy powder JSK covering, thickness 250mcm

4Spindle with square endsStainless steel
5

Size of square rod (shaft).

Hardness of the square must

be 26/38 HRC

In accordance with GOST 8220-85 for fire hydrants, in accordance

with GOST 7499-71

6Internal diameter of the body/case, mm125
9Valve stroke, mmGOST 8220-85
10

Required number of rotations

of rod to be fully open

GOST 8220-85
11

Hydraulic resistance in the hydrant

H = 1000mm, c2m-5, not more

GOST 8220-85
12

Change in hydraulic resistance every

250mm height, c2 m-5, not more

GOST 8220-85
13Hardware projects

Stainless steel 12X18H10T (AISI321), carbonised steel with

thermally diffused zince covering


Part Material
NO.PART NAMEMaterial
1BodyDuctile Iron
2BonnetDuctile Iron
3BoltCarbon Steel
4StemStainless Steel
5DiscDuctie Iron coated by NBR
6London RoundBrass

Technical Specification
Nominal Pressure:1.0,1.6MPa
DN:80mm
Work temperature: ≤120℃
Design Standard :BS
Flange Standard :BS EN 1092
OTHER STANDARD ARE AVAILABLE UPON REQUEST.


China Red Wet Type Fire Hydrant Type A182 F22 Water Globe Valve 2 Way Pedestal With Control Outlet supplier

Red Wet Type Fire Hydrant Type A182 F22 Water Globe Valve 2 Way Pedestal With Control Outlet

Inquiry Cart 0