

Add to Cart
75KW Variable Frequency Inverters 0 to 3000Hz output frequency for
ac motor
EM15 series frequency inverter drives apply V/F vector control and
various protections to control asynchronous motors,adopting
international advanced vector control algorithm with excellent
features. The air duct, hardware and software have been greatly
improved for better environment
adaptability
Products Feature
Support various motor's control mode
Support V/F control, Sensor-less vector control and Closed-loop vector control.
Support several of encoder.
High starting torque character
150% starting torque at 0.5Hz(Open loop vector control without PG)
180% starting torque at 0Hz(Closed vector control with PG)
Technical Specifications
Torque Boost | Auto boost; Manual boost 0.1%~30.0% |
DC braking | 0.00Hz~maximum frequency (DC braking frequency); 0.0s~36.0s(Braking time); 0.0%~100.0%( Braking trigger current value) |
Built-in Simple PLC / Multiple Speeds | It realizes up to 16 speeds via the simple PLC function or combination of DI terminal states. |
Built-in PID | It realizes closed loop control system easily. |
Auto voltage regulation (AVR) | It can keep constant output voltage automatically when the mains voltage fluctuation |
Overvoltage/ Overcurrent Stall Control | The current and voltage are limited automatically during the running process so as to avoid frequently tripping due to overvoltage / over current. |
Virtual I/O | Five groups of virtual DI/DO can realize simple logic control. |
Timing Control | Time range: 0.0~6500.0 minutes |
Motor Overheat Protection | The optional I/O extension card enables AI3 to receive the motor temperature sensor input (PT100, PT1000) so as to realize motor overheat protection. |
Multiple Encoder Types | It supports differential encoder, open-collector encoder |
Protection Mode | Motor short-circuit detection at power-on, input/output phase loss protection, over current and overvoltage protection, less voltage protection, overheat protection and overload protection,etc |
Running Command Giving | key panel; Control terminals; Serial communication port; You can switch between these giving in various ways. |
Programmable Open Collector Output | 1 FMP output terminal, that supports 0–100 kHz square wave signal output (Can be used as DO output) |
Programmable Analog Output | 2 analog output (AO) terminals, both of them supports 0mA~20mA current output and 0V~10V voltage output. |
Relay Output | 2 relay output terminal (2.2KW and below only have 1 relay output terminal) |
Installation Location | Indoor, no direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapour, drip or salt. |
Altitude | Lower than 1000m |
Ambient Temperature | -10°C~ +40°C (de-rated if the ambient temperature is between 40°C and 50°C) |
Model | Power Capacity (KVA) | Input Current | Output Current | Adaptable Motor | |
---|---|---|---|---|---|
KW | HP | ||||
Three phase 380V 50/60Hz | |||||
EM15-G3-d75/P3-1d5 | 1.5/3 | 5/5.8 | 2.1/3.8 | 0.75/1.5 | 1/2 |
EM15-G3-1d5/P3-2d2 | 3/4 | 5.8/10.5 | 3.8/5.1 | 1.5/2.2 | 2/3 |
EM15-G3-2d2/P3-004 | 4/5.9 | 10.5/14.6 | 5.1/9 | 2.2/3.7 | 3/5 |
EM15-G3-004/P3-5d5 | 5.9/8.9 | 14.6/20.5 | 9/13 | 3.7/5.5 | 5/7.5 |
EM15-G3-5d5/P3-7d5 | 8.9/11 | 20.5/26 | 13/17 | 5.5/7.5 | 7.5/10 |
EM15-G3-7d5/P3-011 | 11/17 | 26/35 | 17/25 | 7.5/11 | 10/15 |
EM15-G3-011/P3-015 | 17/21 | 35/38.5 | 25/32 | 11/15 | 15/20 |
EM15-G3-015/P3-018 | 21/24 | 38.5/46.5 | 32/37 | 15/18.5 | 20/25 |
EM15-G3-018/P3-022 | 24/30 | 46.5/62 | 37/45 | 18.5/22 | 25/30 |
EM15-G3-022/P3-030 | 30/40 | 62/76 | 45/60 | 22/30 | 30/40 |
EM15-G3-030/P3-037 | 40/57 | 76/92 | 60/75 | 30/37 | 40/50 |
EM15-G3-037/P3-045 | 57/69 | 92/113 | 75/91 | 37/45 | 50/60 |
EM15-G3-045/P3-055 | 69/85 | 113/128 | 91/112 | 45/55 | 60/75 |
EM15-G3-055/P3-075 | 85/114 | 128/157 | 112/150 | 55/75 | 75/100 |
EM15-G3-075/P3-090 | 114/134 | 157/180 | 150/176 | 75/90 | 100/125 |
EM15-G3-090/P3-110 | 134/160 | 180/214 | 176/210 | 90/110 | 125/150 |
EM15-G3-110/P3-132 | 160/192 | 214/256 | 210/253 | 110/132 | 150/200 |
EM15-G3-132/P3-160 | 192/231 | 256/307 | 253/304 | 132/160 | 200/250 |
EM15-G3-160/P3-200 | 231/250 | 307/385 | 304/377 | 160/200 | 250/280 |
EM15-G3-200/P3-220 | 250/280 | 385/430 | 377/426 | 200/220 | 280/300 |
EM15-G3-220/P3-250 | 280/355 | 430/468 | 426/465 | 220/250 | 300/370 |
EM15-G3-250/P3-280 | 355/396 | 468/525 | 465/520 | 250/280 | 370/400 |
EM15-G3-280/P3-315 | 396/445 | 525/590 | 520/585 | 280/315 | 400/420 |
EM15-G3-315/P3-355 | 445/500 | 590/665 | 585/650 | 315/355 | 420/500 |
EM15-G3-355 | 500 | 665 | 650 | 355 | 500 |
EM15-G3-400 | 560 | 785 | 725 | 400 | 530 |
EM15-G3-450 | 630 | 883 | 820 | 450 | 600 |
EM15-G3-500 | 800 | 920 | 860 | 500 | 660 |
Application
Stone, brick and wood
Energy saving, big torque quickly move up and down.
Torque current control uniform cutting and big torque with low speed.
Start and stop quickly, built-in crafts control.
Steady speed with high accuracy and big torque, high yield of production ratio.
Fan &Water Pump/Air compressor
Support built-in Speed tracking card.
Built -in Pressure closed loop and dormancy awakening, protection function of over pressure.
Built -in extension water supply card, realized one drive for multiple pumps with clock function.
Realized thermostatic control, high Energy-saving rate.
Small volume and high efficiency, frequency inverter and air
compressor be used cooperatively
Textile industry
high starting torque, adapt to wide voltage fluctuation.
Airtight structure can avoid air duct blocked, Wobble function.
built in working records and techniques' curve.
Built-in closed loop, realized high precision synchronous.
Fixed-length function.
Realized permanent magnet synchronous motor open loop control.
What can you buy from us?
Soft Starter, Frequency Inverter, Servo motor and drive
Why should you buy from us not from other suppliers?
We have 6 factories and more than 820 staff. As a professional manufacturer of industrial automation products, we are always dedicated to soft starter, frequency inverter, servo motor and drive, EMI filters, harmonic wave AC choke, sine wave filter.
What's the delivery term?
Accepted Delivery Terms: FOB,CFR,CIF,EXW,CIP,FCA,CPT,DDU, etc