STE18-C is an STS Standard compliant, IC Card type, automatically connection or disconnection smart prepaid electricity meter
Our IC CARD meter also has remote automatic connection and
disconnection function.However, the automatic power off of our
electricity meter after normal operation mainly has the following
functions:
1. Pull the brake to alarm and power off
The purpose of pulling the switch alarm is mainly to remind the
user to buy electricity in time. For example, the power value of
pulling the switch alarm is set to 10 degrees. When the electricity
meter shows that the user has purchased the remaining power of 10
degrees, the relay of the household will automatically cut off to
remind the user to buy electricity in time, and the household
number will flash.Pulling alarm power value can be set through the
computer networking system, can also be set by the IC card sales
management system.
When there is a switch alarm power off, the user should go to the
electricity selling center as soon as possible to buy electricity
and input electricity meter, otherwise, after the user used up the
switch alarm power off value, the electricity meter will be power
off with zero balance.
2.Power off if the balance is zero
When the electricity meter shows that the electricity purchased by
the user is 0 degrees, the relay of the household will
automatically cut off, reminding the user that he must buy
electricity. At this time, the household number flashes and the
electricity consumption is displayed as -0000.0.At this time the
user should as soon as possible to the sale of electricity center
to buy electricity input meter.
3.Malignant load power
When the user uses the "malignant load" such as electric furnace,
electric cup, electric heater and heating fast, the electricity
meter can automatically recognize and power off, and automatically
power on when such load is removed.(This function is suitable for
apartment electricity management, must be customized)
4.Overload power
The electricity meter can set the load current of the user. When
the user's electricity current exceeds the limit current, the
electricity meter will automatically cut off the power supply
circuit and automatically power on after 5 minutes. If the user's
electricity current still exceeds the limit current, the
electricity meter will be cut off again.
5, Timing control power
The electricity meter can control the time of the user's
electricity consumption. The electricity meter can set the time of
automatic power off and power on through the IC card selling system
or the computer networking system, which is convenient for the
management of the user's electricity consumption.
Basic Function:
✽ Meter Recharge By IC Card
✽ Active energy measurement
✽ MD(maximum demand measurement
✽ Auto scroll mode display
✽ Build-in relay control
✽ Event log
Electrical Parameters
Nominal Voltage | 220V/230V/240V |
Working Voltage Range | 70%~120%Un |
Nominal Frequency | 50-60Hz |
Basic Current (Ib) | 5A |
Maximum Current (Imax) | 80A |
Starting Current (Ist) | 20mA |
Active Energy Constant | 1000imp/kWh |
Measurement Accuracy | Class 1.0 |
Power Consumption in Voltage Circuit | <2W <8VA |
Power Consumption in Current Circuit | <1VA |
Operation Temperature Range | -25℃-70℃ |
Storage Temperature Range | -40℃-85℃ |
Electric Magnetic Compatibility
AC Insulation Strength | 4kV at 50Hz during 1min | |
Impulse voltage 1.2/50 us mains connections | 8kV | |
Electrostatic Discharges | Contact discharge | 8kV |
Air discharge | 16kV | |
Electromagnetic RF Field | 27MHz-500MHz | 10V/m |
100KHz-1GHz | 30V/m | |
Fast transient burst test | 4kV | |
Protection | Class II |
Meter Dimensions