Add to Cart
Metal Sheathed Mineral Insulated RTD Cable for Temperature
Detecting, also called RTD MIC, compose of copper or Nickel signal
wire conductors and stainless steel or Inconel outer metal sheath.
The mineral normally known as compact magnesium oxide are filled
between the space of nearby conductor lead wires. There are several
choices for the core numbers such as 2 ,3 , 4 or 6 showing the
number of wire internal conductors.
Features
Specification
Take the KSK2B30 as example to explain the specification
Example | K | S | K | 2 | B | 30 |
KSK2B30 | K=thermocouple cable | Sheath material | Conductor Combinations | Number of Conductors | EMF Characteristics | Sheath Diameter (mm)ⅹ10 |
Thermocouple Precision Grade
The EMF thermocouple output and tolerance are met with products
covered in this specification and are certified at a given
temperature.
Conductor Combination Reference | Calibration Temperatures ℃ | Tolerances | |
J | 200 400 700 | Grade 1 | Grade 2 |
K&N | 200 400 600 800 1000 | -40℃ to 375℃ within ±1.5℃ | --40℃ to 333℃ within ±2.5℃ |
E | 200 400 600 800 | -40℃ to 375℃ within ±1.5℃ | -40℃ to 333℃ within ±2.5℃ |
T | 200 400 | -40℃ to 125℃ within ±1.5℃ | -40℃ to 133℃ within ±2.5℃ |
Note: the maximum calibration temperature should not exceed the
maximum continuous operation temperature of the sheath material.
Specification of the Thermocouple Cable
Cable Diameter | Conductor Diameter and Number | Minimum Insulation Thickness | Minimum Sheath Thickness | ||||
Nominal± Tolerance | 2-core Minimum | 4-core Nominal | 6-core Nominal | 2-core | 2-core | 4-core | 4-core |
0.5±0.025 | 0.08 | - | - | 0.04 | 0.05 | - | - |
1.0±0.025 | 0.15 | - | - | 0.08 | 0.10 | - | - |
1.5±0.025 | 0.23 | - | - | 0.12 | 0.15 | - | - |
2.0±0.025 | 0.30 | - | - | 0.16 | 0.20 | - | - |
3.0±0.025 | 0.45 | - | 0.24 | 0.30 | 0.30 | - | |
3.2±0.032 | 0.48 | - | 0.26 | 0.32 | |||
4.0±0.040 | 0.60 | - | - | 0.32 | 0.40 | - | - |
4.5±0.045 | 0.68 | 0.51 | - | 0.36 | 0.45 | - | - |
4.8±0.048 | 0.72 | - | - | 0.384 | 0.48 | - | - |
5.0±0.050 | 0.75 | - | - | 0.4 | 0.50 | - | - |
6.0±0.060 | 0.90 | 0.68 | 0.68 | 0.48 | 0.60 | 0.59 | 0.59 |
6.4±0.064 | 0.96 | - | - | 0.512 | 0.64 | - | - |
8.0±0.080 | 1.20 | 0.91 | - | 0.64 | 0.80 | 0.79 | - |
Note: jumbo sizes approximately equivalent to the above diameters
are normally available.
Maximum Recommended Continuous Working Temperature
Sheath Materials | Temperature ℃ | Thermocouple Type | Temperature ℃ |
C | 250 | T | 400 |
D | 400 | J | 750 |
QRST | 800 | E | 800 |
WI | 1100 | K | 1200 |
N | 1250 | N | 1250 |
Quality Inspection
When product manufacture is finished, every coil of cable should
undergo a series of quality assurance tests.
1 Sheath integrity (water immersion test)
2 Dimensional tolerances
3 Surface finish
4 EMF calibration
5 Insulation resistance
6 Sheath ductility
7 Conductor ductility
Testing report is available upon request. Additional specialty