Heat Tracing Mineral Insulated Thermocouple Cable Inconel 600

Brand Name:MICH
Certification:ISO9001
Model Number:IC600SMITHC
Minimum Order Quantity:1 meter
Delivery Time:in one month
Payment Terms:L/C, T/T
Contact Now

Add to Cart

Verified Supplier
Address: 1200 N Fuxing Rd Wutong Dist Tongxiang 314500 Zhejiang P. R China
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details
INCONEL 600 SHEATHED Mineral Insulated CABLES offer excellent oxidation resistance and a strength at very high temperatures (up to 1150 °C). Not recommended for in sulphur atmospheres higher than 550 °C.

Application

High temperature pipeline heat tracingAnti-coagulation and viscosity decreasing for process media
Tank/vessel heatingMetal manufacturing industry -- low melting point alloy melting
Extruder shell heatingRecycling of nuclear fuel waste
All kinds of industrial electric heaters

Cable Structure


Specification

Heating cable instruction code

MI AL-B 16K6560/60/2520/220/E1

No. 1 2 3 4 5 6 7

No.Instruction
1Sheath material825 alloy
2structure of cable componentsshown in table 1
3cable codesshown in table 2, 3 and 4
4length of heating cableIn meter
5Heating cable powerIn Watt
6heating cable voltageIn Volt
7heating cable voltageSee table 5

Cable Code

1 6 K 6560

No. 1 2 3 4

Serial NO.Instruction
1core number1 or 2
2Voltage grade3=300V, 6=600V
3conductor materialsK,N,C
4cold resistance ×10006560=6.56Ω/m×1000

Table 1 Structure of Cable Element

Table 2 Heating Cable Specification (600V Single Core)


Cable CodeDiameterNominal resistance at +20Maximum manufacturing lengthUnit weight
mmΩ/mmkg/km
16C2.16.80.0021130220.7
16C3.45.90.0034173162.5
16C5.35.30.0053214125.6
16C8.54.80.0085261101.6
16C134.30.01332579.1
16C214.00.02137665.8
16K405.80.04179157.1
16K505.40.05206135.6
16K605.20.06222122.8
16K804.80.08261101.2
16K1004.70.120099.5
16K1204.50.1220088.8
16K1606.50.16200202.2
16K2005.90.2200166.5
16K2505.30.25215131.7
16K4004.70.428096.7
16K5004.50.530087.7
16N6304.30.6318582.2
16N10003.91.023062.8
16N16003.61.627052.4
16N25003.42.530045.6
16N28003.42.830045.2
16N33003.43.330044.7
16N40003.24.035038.1
16N52003.25.235037.7
16N63003.26.335038.4
16N100003.21035038.9

Table 3 Heating Cable Specification (600V Double Cores)


Cable CodeDiameterNominal resistance at +20Maximum manufacturing lengthUnit weight
mmΩ/mmkg/km
26K8.411.80.008443632.9
26K13.49.80.013463431.5
26K218.80.02178339.0
26K348.00.03494273.7
26K547.10.054119212.4
26K856.40.085147170.2
26K1306.00.13167147.8
26K1807.90.1896271.9
26K2607.40.26110234.2
26K3606.80.36130195.5
26K5006.40.5100171.2
26K6505.90.65100144.8
26K10005.71.0100133.3
26K13006.21.3100160.6
26K20005.82.0100139.1
26K33005.43.3100118.8
26N46005.84.6100138.3
26N80005.48.0100118.6
26N130005.013.0100100.8
26N270004.827.010092.1
26N400004.640.010084.4
26N600004.460.010077.1
26N720004.272.010070.2

Table 4 Heating Cable Specification (300V Double Cores)


Cable CodeDiameterNominal resistance at +20Maximum manufacturing lengthUnit weight
mmΩ/mmkg/km
23K2105.20.21222117.9
23K3004.80.326198.9
23K4004.80.426197.2
23K4804.80.4826196.0
23K6504.60.6528487.3
23K10004.11.010068.9
23K13003.81.310058.9
23K20005.02.0100104.7
23K24004.82.410095.7
23K30004.63.010087.3
23N46004.84.610096.3
23N75004.67.510086.9
23N112004.411.210078.7
23N140004.214.010071.6
23N180003.618.010052.6
23N260003.626.010052.2
23N400003.440.010046.4
23N500004.050.010063.8
23N600003.660.010051.7
23N720003.472.010046.1

Note: the resistance value of 2-core cable in the above table is the measured value after the ends are twisted (i.e., single-core resistance X2);

For the use of 660V voltage occasions, please contact our company professionals.


Table 5 terminal specifications


Model: A, D, EModel: B
Maximum Voltage(V)Maximum Current (A)Terminal SpecificationMaximum Current (A)Terminal Specification
60015E220E1
60020E225E2
60030E340E2
60050E370E2
60070E3100E3

Note 1: E1 means 1/2 "NPT;E2 means 3/4 "NPT;E3 represents 1 "NPT (taper thread);Additional connection thread requirements are available.

Note 2: the length of cold end cable with standard configuration is 2 meters. If you increase or decrease of length required, please contact our professional personnel.


Corresponding reference table between the output power and sheath temperature

Anticorrosive specification


Material
Sulfategood
Hydrochloric acidgood
Hydrofluoric acidgood
Phosphategood
Carbonategood
Organic acidgood
Alkali metalgood
Sea watergood
Chloridegood

Explosion-proof instructions

MIAL series heating cable with explosion-proof terminal, can be used in potential explosive environment. Authenticated by the Chinese CQST, in accordance with Chinese GB3836 explosion-proof electrical standards, they can be applicable to A, B, C (C1D2) level of explosion-proof electrical equipment.

China Heat Tracing Mineral Insulated Thermocouple Cable Inconel 600 supplier

Heat Tracing Mineral Insulated Thermocouple Cable Inconel 600