SS Mineral Insulated Wire Alloy Melting Low Melting Point

Brand Name:MICH
Certification:ISO9001
Model Number:MIHC
Minimum Order Quantity:1 meter
Delivery Time:in one month
Payment Terms:L/C, T/T
Contact Now

Add to Cart

Verified Supplier
Address: 1200 N Fuxing Rd Wutong Dist Tongxiang 314500 Zhejiang P. R China
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

Low Melting Point Alloy Melting Use MI Heating Cable for Metal Manufacturing Industry can meet the requirements of high temperature condition and high heating power (up to 269W/m).The maximum heating temperature can reach up to 600℃. Conductor resistance value ranges from 2.1 to 36100Ω/km supplied by MICH. Mineral insulated heating cable possesses excellent mechanical strength and corrosion resistance. The heating cable of series resistance can meet the requirements of different power.


Application


Nuclear industryconstruction -- asphalt heating
Metal manufacturing industry- low melting point alloy meltingtank/vessel heating
Shell heating for the extruderHeat tracing for high temperature industrial piping
anticoagulation and viscosity reduction of process mediaAll kinds of industrial electric heaters

Cable Structure

Specification

Heating cable instruction code


MI SS-B 16K6560/60/2520/220/E1

NO. 1 2 3 4 5 6 7


No.Instruction
1Sheath materialStainless steel
2structure of cable componentsshown in table 1
3cable codesshown in table 2, 3 and 4
4length of heating cableIn meter
5Heating cable powerIn Watt
6heating cable voltageIn Volt
7heating cable voltageSee table 5

Cable Code

Serial NO.Instruction
1core number1 or 2
2Voltage grade3=300V, 6=600V
3conductor materialsK,N,C
4cold resistance ×10006560=6.56Ω/m×1000

1 6 K 6560

No 1 2 3 4


Table 1 Structure of Cable Element

Table 2 Heating Cable Specification (600V Single Core)


Cable CodeDiameterNominal resistance at +20Maximum manufacturing lengthUnit weight
mmΩ/mmkg/km
16C2.16.80.0021130184.2
16C3.45.90.0034173138.7
16C5.35.30.0053214111.9
16C8.54.80.008526191.8
16C134.30.01332573.7
16C214.00.02137663.8
16K405.80.04179164.7
16K505.40.05206140.1
16K605.20.06222126.7
16K804.80.08261106.8
16K1004.70.1200100.0
16K1204.50.1220090.2
16K1606.50.1620077.7
16K2005.90.2200110.0
16K2505.30.2521592.1
16K4004.70.428074.0
16K5004.50.530066.2
16N6304.30.6318594.1
16N10003.91.023091.3
16N16003.61.627088.2
16N25003.42.530069.8
16N28003.42.830076.0
16N33003.43.330068.9
16N40003.24.035068.5
16N52003.25.235068.2
16N63003.26.335055.5
16N100003.21035041.7

Table 3 Heating Cable Specification (600V Double Cores)


Cable CodeDiameterNominal resistance at +20Maximum manufacturing lengthUnit weight
mmΩ/mmkg/km
26K8.411.80.008443636.1
26K13.49.80.013463433.7
26K218.80.02178340.7
26K348.00.03494275.2
26K547.10.054119213.6
26K856.40.085147171.2
26K1306.00.13167148.6
26K1807.90.1896273.3
26K2607.40.26110235.4
26K3606.80.36130196.6
26K5006.40.5100172.1
26K6505.90.65100145.6
26K10005.71.0100134.1
26K13006.21.3100161.5
26K20005.82.0100139.8
26K33005.43.3100119.5
26N46005.84.6100139.0
26N80005.48.0100119.2
26N130005.013.0100101.3
26N270004.827.010092.6
26N400004.640.010084.9
26N600004.460.010077.5
26N720004.272.010070.6

Table 4 Heating Cable Specification (300V Double Cores)


Cable CodeDiameterNominal resistance at +20Maximum manufacturing lengthUnit weight
mmΩ/mmkg/km
23K2105.20.21222118.5
23K3004.80.326199.4
23K4004.80.426197.7
23K4804.80.4826196.5
23K6504.60.6528487.8
23K10004.11.010069.3
23K13003.81.310059.3
23K20005.02.0100105.3
23K24004.82.410096.2
23K30004.63.010087.8
23N46004.84.610096.8
23N75004.67.510087.4
23N112004.411.210079.2
23N140004.214.010072.0
23N180003.618.010052.9
23N260003.626.010052.5
23N400003.440.010046.6
23N500004.050.010064.2
23N600003.660.010052.0
23N720003.472.010046.4

Note:

The resistance value of 2-core cable in the above table is the measured value after the ends are twisted (i.e., single-core resistance X2);

If not specified, the sheath material is based on SS 321;

For the use of 660V voltage occasions, please contact our company professionals.


Table 5 terminal specifications


Model: A, D, EModel: B
Maximum Voltage (V)Maximum Current (A)Terminal SpecificationMaximum Current (A)Terminal Specification
60015E220E1
60020E225E2
60030E340E2
60050E370E2
60070E3100E3

Note 1: E1 means 1/2 "NPT;E2 means 3/4 "NPT;E3 represents 1 "NPT (taper thread);Additional connection thread requirements are available.

Note 2: the length of cold end cable with standard configuration is 2 meters. If increase or decrease of length required, please contact our professional personnel.


Corresponding reference table between the output power and sheath temperature


Anticorrosive specification

MaterialApplication
SulfateNot Recommend
Hydrochloric acidNot Recommend
Hydrofluoric acidNot Recommend
PhosphateNot Recommend
CarbonateAccording to the real Data
Organic acidApplicable at any condition
Alkali metalAcceptable
Sea waterNot Recommend
ChlorideNot Recommend

Explosion-proof instructions

MISS series heating cable with explosion-proof terminal, can be used in potential explosive environment. Authenticated by the Chinese CQST, in accordance with Chinese GB3836 explosion-proof electrical standards, they can be applicable to A, B, C (C1D2) level of explosion-proof electrical equipment.