High Efficiency of Electrothermal Conversion Mineral Insulated Heating Element possesses good property on high efficiency of electrothermo conversion compared to other heating solutions.
Using the principle of the thermal effect of electrical current (Joule-Lenz law), the pure resistance heats up, converting almost 100% electric energy into heat energy.
Mineral Insulated Heating Element for Chemical Industry Heating or Heat Trace is to be designed based on selection of mineral insulated heating cable which is prefabricated in the manufacturer's workshop into a heating element that can be directly connected to the power supply. It is usually composed of heating cables, cold and hot joints, cold end cables, terminals, tail ends and lead wires, etc. There are the following types can be selected from including type A, Type B, Type C, Type D, Type E, Type F and Type G structures. Among them, Type A, B and C are only suitable for single-core heating cable, while type D, E, F and G are only suitable for double-core heating cable.
Common structure of the heating cable for the heating element is of single core and two core, while the customization can be according to clients’ needs to design and provide MI heating cable of three core or more.
Specifications
Heating cable instruction code
NO. 1 2 3 4 5 6 7MI CN-B 16K239/60/2520/220/E1
NO. | Instruction | |
1 | core number | 1 or 2 |
2 | Voltage grade | 3=300V, 6=600V |
3 | conductor materials | K,N,C |
4 | cold resistance ×1000 | 239=0.239Ω/m×1000 |
Cable Code
1 6 K 239
No. 1 2 3 4
No. | Instruction | |
1 | Sheath material | Cu-Ni |
2 | structure of cable components | shown in table 1 |
3 | cable codes | shown in table 2, 3 and 4 |
4 | length of heating cable | In meter |
5 | Heating cable power | In Watt |
6 | heating cable voltage | In Volt |
7 | heating cable voltage | See table 5 |
Table 2 Heating Cable Specification (600V Single Core)
Cable Code | Diameter | Nominal resistance at +20℃ | Maximum manufacturing length | Unit weight |
mm | Ω/m | m | kg/km | |
16C2.1 | 6.8 | 0.0021 | 130 | 220.7 |
16C3.4 | 5.9 | 0.0034 | 173 | 162.5 |
16C5.3 | 5.3 | 0.0053 | 214 | 125.6 |
16C8.5 | 4.8 | 0.0085 | 261 | 101.6 |
16C13 | 4.3 | 0.013 | 325 | 79.1 |
16C21 | 4.0 | 0.021 | 376 | 65.8 |
16K40 | 5.8 | 0.04 | 179 | 157.1 |
16K50 | 5.4 | 0.05 | 206 | 135.6 |
16K60 | 5.2 | 0.06 | 222 | 122.8 |
16K80 | 4.8 | 0.08 | 261 | 101.2 |
16K100 | 4.7 | 0.1 | 200 | 99.5 |
16K120 | 4.5 | 0.12 | 200 | 88.8 |
16K160 | 6.5 | 0.16 | 200 | 202.2 |
16K200 | 5.9 | 0.2 | 200 | 166.5 |
16K250 | 5.3 | 0.25 | 215 | 131.7 |
16K400 | 4.7 | 0.4 | 280 | 96.7 |
16K500 | 4.5 | 0.5 | 300 | 87.7 |
16N630 | 4.3 | 0.63 | 185 | 82.2 |
16N1000 | 3.9 | 1.0 | 230 | 62.8 |
16N1600 | 3.6 | 1.6 | 270 | 52.4 |
16N2500 | 3.4 | 2.5 | 300 | 45.6 |
16N2800 | 3.4 | 2.8 | 300 | 45.2 |
16N3300 | 3.4 | 3.3 | 300 | 44.7 |
16N4000 | 3.2 | 4.0 | 350 | 38.1 |
16N5200 | 3.2 | 5.2 | 350 | 37.7 |
16N6300 | 3.2 | 6.3 | 350 | 38.4 |
16N10000 | 3.2 | 10 | 350 | 38.9 |
Table 3 Heating Cable Specification (600V Double Cores)
Cable Code | Diameter | Nominal resistance at +20℃ | Maximum manufacturing length | Unit weight |
mm | Ω/m | m | kg/km | |
26K8.4 | 11.8 | 0.0084 | 43 | 632.9 |
26K13.4 | 9.8 | 0.0134 | 63 | 431.5 |
26K21 | 8.8 | 0.021 | 78 | 339.0 |
26K34 | 8.0 | 0.034 | 94 | 273.7 |
26K54 | 7.1 | 0.054 | 119 | 212.4 |
26K85 | 6.4 | 0.085 | 147 | 170.2 |
26K130 | 6.0 | 0.13 | 167 | 147.8 |
26K180 | 7.9 | 0.18 | 96 | 271.9 |
26K260 | 7.4 | 0.26 | 110 | 234.2 |
26K360 | 6.8 | 0.36 | 130 | 195.5 |
26K500 | 6.4 | 0.5 | 100 | 171.2 |
26K650 | 5.9 | 0.65 | 100 | 144.8 |
26K1000 | 5.7 | 1.0 | 100 | 133.3 |
26K1300 | 6.2 | 1.3 | 100 | 160.6 |
26K2000 | 5.8 | 2.0 | 100 | 139.1 |
26K3300 | 5.4 | 3.3 | 100 | 118.8 |
26N4600 | 5.8 | 4.6 | 100 | 138.3 |
26N8000 | 5.4 | 8.0 | 100 | 118.6 |
26N13000 | 5.0 | 13.0 | 100 | 100.8 |
26N27000 | 4.8 | 27.0 | 100 | 92.1 |
26N40000 | 4.6 | 40.0 | 100 | 84.4 |
26N60000 | 4.4 | 60.0 | 100 | 77.1 |
26N72000 | 4.2 | 72.0 | 100 | 70.2 |
Table 4 Heating Cable Specification (300V Double Cores)
Cable Code | Diameter | Nominal resistance at +20℃ | Maximum manufacturing length | Unit weight |
mm | Ω/m | m | kg/km | |
23K210 | 5.2 | 0.21 | 222 | 117.9 |
23K300 | 4.8 | 0.3 | 261 | 98.9 |
23K400 | 4.8 | 0.4 | 261 | 97.2 |
23K480 | 4.8 | 0.48 | 261 | 96.0 |
23K650 | 4.6 | 0.65 | 284 | 87.3 |
23K1000 | 4.1 | 1.0 | 100 | 68.9 |
23K1300 | 3.8 | 1.3 | 100 | 58.9 |
23K2000 | 5.0 | 2.0 | 100 | 104.7 |
23K2400 | 4.8 | 2.4 | 100 | 95.7 |
23K3000 | 4.6 | 3.0 | 100 | 87.3 |
23N4600 | 4.8 | 4.6 | 100 | 96.3 |
23N7500 | 4.6 | 7.5 | 100 | 86.9 |
23N11200 | 4.4 | 11.2 | 100 | 78.7 |
23N14000 | 4.2 | 14.0 | 100 | 71.6 |
23N18000 | 3.6 | 18.0 | 100 | 52.6 |
23N26000 | 3.6 | 26.0 | 100 | 52.2 |
23N40000 | 3.4 | 40.0 | 100 | 46.4 |
23N50000 | 4.0 | 50.0 | 100 | 63.8 |
23N60000 | 3.6 | 60.0 | 100 | 51.7 |
23N72000 | 3.4 | 72.0 | 100 | 46.1 |
Note: the resistance value of 2-core cable in the above table is the measured value after the end is twisted (i.e., single-core resistance X2);
For the use of 660V voltage occasions, please contact our company professionals.
Table 5 terminal specifications
Model: A, D, E | Model: B | |||
Maximum Voltage (V) | Maximum Current (A) | Terminal Specification | Maximum Current (A) | Terminal Specification |
600 | 15 | E2 | 20 | E1 |
600 | 20 | E2 | 25 | E2 |
600 | 30 | E3 | 40 | E2 |
600 | 50 | E3 | 70 | E2 |
600 | 70 | E3 | 100 | E3 |
Note 1: E1 means 1/2 "NPT;E2 means 3/4 "NPT;E3 represents 1 "NPT (taper thread);Additional connection thread requirements are available.
Note 2: the length of cold end cable with standard configuration is 2 meters. If you increase or decrease of length required, please contact our professional personnel.
Corresponding reference table between the output power and sheath temperature
Anticorrosive specification
Material | ||
Sulfate | Not recommend | |
Hydrochloric acid | Data checking required | |
Hydrofluoric acid | Data checking required | |
Phosphate | Data checking required | |
Carbonate | Data checking required | |
Organic acid | Data checking required | |
Alkali metal | Data checking required | |
Sea water | Excellent | |
Chloride | Excellent |
Explosion-proof instructions
MICN series heating cable with explosion-proof terminal, can be used in potential explosive environment. Authenticated by the Chinese CQST, in accordance with Chinese GB3836 explosion-proof electrical standards, they can be applicable to Ⅱ A, Ⅱ B, Ⅱ C (C1D2) level of explosion-proof electrical equipment.