Electric Steam Turbine Bolt Mi Heater Metal Sheathed

Brand Name:MICH
Certification:ISO9001
Model Number:MSMISTBEH
Minimum Order Quantity:1 piece
Delivery Time:in one month
Place of Origin:China
Contact Now

Add to Cart

Verified Supplier
Address: 1200 N Fuxing Rd Wutong Dist Tongxiang 314500 Zhejiang P. R China
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

Metal Sheathed Mineral Insulated Steam Turbine Bolt Electric Heater is designed and manufactured based on the mineral insulated heating cable made of high-temperature resistance alloy wire conductor, stainless steel tube as protective sheath insulated with high purity magnesium oxide cylinders, which is formed after compression process to ensure the use of electric heating element.


There are three kinds of protective sheath: straight type, semi-soft type and full soft type.


Steam turbine bolt electric heater is specially produced based on advanced technology, specializing in heating for hollow bolts of steam turbine or large machinery during the installation and maintenance, to meet the requirements of fastening and disassembly.


Properties


1. The electric heating rod uses the mineral insulation (MI) heating cable developed by MICH as the heating element.

2. The electric heating rod has a solid structure, high flexural strength, compactness, sealing and explosion-proof, and meets the requirements for heating and heat tracing of various types of storage tanks for petroleum and its products with an explosion-proof grade dIIB T1~T6.

3. The electric heating rod heats uniformly, low surface heat load, reliable operation and long service life, no reactive power loss, high thermal efficiency, easy operation and maintenance and no daily maintenance required.

4. The electric heating rod has good corrosion resistance to crude oil and its finished products.


Specifications, models and working environment requirements


Model and specification sheet


Table 1 Model and Specification of Straight Tank Electric Heating Rod

No.ModelNominal power (Kw)Rated voltage (V)Operating current (A)Number of power phasesRod Outer diameter × length (mm)Insertion length (mm)Mounting short section size (mm)Total weight (kg)
1DRB-3/220/1600322013.61Ф127×16001300Ф159×552
2DRB-5/220/2200522022.51Ф127×22001900Ф159×565
3DRB-8/220/2800822036.41Ф127×28002500Ф159×595
4DRB-9/3/660/3600966013.63Ф127×36003300Ф159×5102
5DRB-12/3/660/50001266018.23Ф127×50004700Ф159×5112
6DRB-15/3/660/56001566022.73Ф127×56005300Ф159×5142
7DRB-24/3/660/64002466036.43Ф127×64006100Ф159×5170
8DRB-3/3/380/130033804.53Ф127×13001000Ф159×565
9DRB-5/3/380/220053807.53Ф127×22001900Ф159×580
10DRB-9/3/380/3400938013.63Ф127×34003400Ф159×5110
11DRB-12/3/380/50361238018.23Ф127×50364565Ф159×598
12DRB-15/3/380/56001538022.73Ф127×56005300Ф159×5142
13DRB-24/3/380/64002438036.43Ф127×64006100Ф159×5170

Table 2 Model and Specification of Right Angle Tank Electric Heating Rod


No.ModelNominal power (Kw)Rated voltage (V)Operating current (A)Number of power phasesRod Outer diameter × length (mm)Immersion length (mm)Total weight (kg)
1DRB-3/220/1600/L322013.61Ф127×1600160057
2DRB-5/220/2200/L522022.51Ф127×2200220070
3DRB-8/220/2800/L822036.41Ф127×28002800100
4DRB-9/3/660/3600/L966013.63Ф127×36003600107
5DRB-12/3/660/5000/L1266018.23Ф127×50005000117
6DRB-15/3/660/56001566022.73Ф127×56005600147
7DRB-2/3/380/1100/L23803.03Ф127×1100110060
8DRB-3/3/380/1300/L33804.53Ф127×1300130070
9DRB-5/3/380/1900/L53807.53Ф127×1900190090
10DRB-9/3/380/3400/L938013.63Ф127×34003400115
11DRB-12/3/380/5000/L1238018.23Ф127×50005000109
12DRB-15/3/380/5600/L1538022.73Ф127×56005600147

Note: The specifications above are regular ones with other specifications customizable according to user’s requirements, and the installation nipple joint is suppliable with the product.


3. Working environment requirements:

3.1 Ambient temperature: -30 ° C ~ +40 ° C

3.2 Voltage fluctuations are: -10% to +5%

3.3 Altitude: not required

3.4 Relative humidity of the environment: less than 95%

4, working principle and structure

1. working principle

The electric heating rod adopts a mineral insulated (MI) heating cable as heating element. The inner cavity of the rod can rapidly conduct heat that are fully transmitted to the rod body and released to the medium through the outer surface of the rod, and the electric energy is all converted into heat energy with a high heat transfer efficiency.



Figure 1: Schematic diagram of Straight Tank Electric Heating Rod Structure



1 Rod Casing 2 Core Tube 3 Mineral Insulated Heating Cable 4. Over-temperature Protective Sensor 5. Junction Box 6. Installation Nipple Joint


Figure 2: Schematic diagram of DRB--L (right angle) electric heating rod


1 Mineral Insulated Heating Cable 2 Outer Casing 3 Core Tube 4 Over Temperature Protection Sensor 5 Junction Box


Note: DRB--L type is a special structure of DRB type electric heating rod, which is specially designed for small oil tanks already in use. It can be installed in tank man hole without cleaning the inside or re-opening a new hole. The heating part is in the lower horizontal section while the vertical part is only the lead-out line section. The joint flange is arranged at the upper end of the vertical section, and the electrical wiring can be adjusted in a suitable direction and position.

China Electric Steam Turbine Bolt Mi Heater Metal Sheathed supplier

Electric Steam Turbine Bolt Mi Heater Metal Sheathed

Inquiry Cart 0