Photoelectric Smoke Alarm With 10-Year Lithium Battery Battery
Operated CO Detector
Photoelectric smoke detector fire alarm use a photoelectric sensor
to quickly detect smoldering, slow burning smoke from wide ranges
before catching flames. The fire detector does not contain any
radioactive material, fire-retardant and eco-friendly material free
from harsh smells and chemicals, making it great for bedrooms.
Home smoke detectors alerts of smoldering smoke sounding a clear
85-decibel and blinking LED light. Use microprocessor control, no
false alarms. This smoke alarm meets TUV CE certification for approved installation and safety requirements for homes depot
businesses hotel school office.
Wireless smoke detector is operated by a 9V battery(included) for
wireless, hassle-free installation and no worry potential outages
during a power failure. The long-lasting battery and life span
reduces reminders for battery changing, flashing red LED lights to
signal when a battery change is needed.
Easy-to-use smoke alarm includes a with a silence/ single test
button to silence the hush functionality and quickly test the home
fire alarm during monthly check-ups.
Great fire alarm for home, office, business, apartments, garage,
hospital, classroom. Also it perfect as a gift for Christmas,
birthday and holiday. If you need any assistance or have any
confused, just email us, we are always here to help you with any
problem.
Sepcification
Product name | Photoelectric Smoke Alarm With 10-Year Lithium Battery |
Audible alarm | ≥85 dB at 3m |
Working distance | Up to 100m (Outdoor open) |
Frequency | 433.92MHz or 868MHz (Customized) |
Temperature | 0℃~40℃ |
Humidity | ≤95%RH non-condense |
Battery | 10-Year Lithium Battery |
Operation Current | <10uA (standby); <70mA (alarm) |
Alarm Sensitivity | 0.09 - 0.17 dB/m |
Silence Time | Approx. 10 minutes |
LED Indicators
1. Normal status: Red LED Flashes once every 60 seconds.
2. Test status: Red LED flashes once every second.
3. Hush/Silence mode: Red LED flashes once every 8 seconds.
4. Low Battery status: Red LED flashes once every 60 seconds and 1
beep every 60 seconds.
5. Fault status: the alarm will deliver beeps every 40 seconds.
Interlinked smoke detector
Radio-interlinked smoke detectors are interlinked through
radiofrequency signals. If one smoke alarm detects fire, all alarms
go
off. In the case of the battery operated radio-interlinked smoke
alarms, no wiring is required at all.
How to create the interlinked network
Step 1: Press the test/silence button on one of these smoke alarms
4 times, and the green LED will rapidly flash continuously,
indicating it has entered the transmitting mode (valid time: 60
seconds) .
Step 2: Press the test/silence button on the other smoke alarms
twice, and the green LED will slowly flash continuously,indicating
it has entered the receiving mode.
-----If pairing is successful: The green LED of these alarms will
stop flashing.
-----When it is failure: The green light will continue to flash for
60 seconds, and then the red light will stay on for 2 seconds.
How to disabling the interconnect function
Press the test/silence button on the smoke alarms twice and the
green LED will slowly flash continuously still 60 seconds, then
ignore it and it will automatic despairing.
How to silence the alarms in network when alarm
If the smoke alarm detects fire, the device will goes into
Source/Master smoke alarm sound pattern alarmed, and emits the
alarm signal;
When other alarm devices received alarm signal, they will goes into
Slave smoke alarm sound pattern, until the Source/Master alarm
device stopped alarm; During the unit is alarming, you can find out
the Source/Master smoke alarm , press the Test/Silence button to
pause all other
interconnected alarms.
Replaced Battery
1. The low battery signal can last for maximum 30 days, please
replace the batteries in time to keep it working properly.
2. Battery required: 10-Year Lithium Battery
3. Acceptable brand: Duracell MN1500, Golden Peak LR6, GP GN15A,
etc.
4. Correctly install the positive and negative poles of the battery
(“+” & “-”)
5. Waste batteries should not be placed into any household waste or
recycling bin as all of them have the potential to spark. Check
with your Local Authority for recycling advice.
Trouble Shooting
1. The alarm does not sound when testing
Please check whether the batteries be well assembled according to
the Guide required
2. Red LED flashes and the alarm delivers one beep every 60 second
The battery is low. Please replace the batteries as soon as
possible.
3. The alarm delivers one beep every 40 seconds
clean the alarm. please refer to the“maintenance and cleaning”
section.
The alarm is malfunctioning. Contact the retailer to replace it.
4. Nuisance alarms triggered intermittently or when residents are
cooking, taking showers, etc.
Press silence button.
Clean the alarm. Please refer to the “maintenance and cleaning”
section.
Move the alarm to new location.
FAQ
Q: How can i place an order?
Please provide the details of your requirements as clear as
possible. So we can send you the offer at the first time.
A: For designing or further discussion, it is better to contact us
with Skype / email / phone, in case of any delays.
Q: How about the quality of the personal alarm ?
A:We produce every product with good quality materials and fully
test three times before shippment. What is more, our quality
areapproved by CE RoHS SGS & FCC, IOS9001, BSCI.
Q: Can i have a sample order?
A: Yes, we welcome sample order to test and check quality. Mixed
samples are acceptable.
Q:What is your terms of delivery?
A: We accept EXW, FOB, CFR, CIF, DDU, DDP, etc. You can choose the
one which is the most convenient or cost effective for you.
Q: How do you ship the goods and how long does it take arrive?
A:We usually ship by DHL(3-5days), UPS(4-6days), Fedex(4-6days),
TNT(4-6days), Air(7-10days), or by sea(25-30days)at your request.