3 Year Battery Wireless Interconnected Smoke Detector Fire Alarm Sensor

Brand Name:Ariza
Certification:EN14604:2005/AC:2008
Model Number:SM11R
Minimum Order Quantity:500pcs
Delivery Time:7-15days
Payment Terms:T/T, Western Union, MoneyGram,Paypal
Contact Now

Add to Cart

Active Member
Location: Shenzhen Chongqing China
Address: The 2nd floor of B1 building,Xinfu industry zone,Chongqing Rd.,Heping village,Fuyong Town,Bao'an district,Shenzhen,China 518103
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

3 Year Battery Wireless Interconnected Smoke Detector Fire Alarm Sensor

When one alarm is triggered, all interlinked smoke alarms will sound, so you and your family can hear the alarm from anywhere in your home; an intelligent locating function allows you to quickly locate the source of the fire, giving you every extra life-saving second to control the fire or evacuate
Wide Coverage for Full Home Protection: Featuring a relay function that extends transmission range, this radio-interlinked alarm can be interconnected with up to 30 smoke alarms to create a smart home network
3-Year Replaceable Battery & Self-Check: The battery supports 3-year continuous use and can be easily replaced by yourself; a low-battery warning lets you know when it’s time to replace the battery

Sepcification

Product name3 Year Battery Wireless Interconnected Smoke Detector
Audible alarm
≥85dB at 3m
Working distance
Up to 100m (Outdoor open)
Frequency
433.92MHz or 868MHz (Customized)
Temperature
0℃~40℃
Humidity
≤95%RH non-condense
Battery10-Year Lithium Battery
Operation Current<10uA (standby); <70mA (alarm)
Source/Master smoke alarm sound pattern
BI 0.5s - pause 0.5s
– BI 0.5s – pause 0.5s – BI 0.5s – pause 1.5s, with the red LED
flash, repeat this alarm pattern.
Slave smoke alarm sound pattern
BI 0.1s - pause 0.1s with the
red LED flash and sound, repeat this alarm pattern.

LED Indicators
1. Normal status: Red LED Flashes once every 60 seconds.
2. Test status: Red LED flashes once every second.
3. Hush/Silence mode: Red LED flashes once every 8 seconds.
4. Low Battery status: Red LED flashes once every 60 seconds and 1 beep every 60 seconds.
5. Fault status: the alarm will deliver beeps every 40 seconds.
Interlinked smoke detector

Radio-interlinked smoke detectors are interlinked through radiofrequency signals. If one smoke alarm detects fire, all alarms go
off. In the case of the battery operated radio-interlinked smoke alarms, no wiring is required at all.
How to create the interlinked network

Step 1: Press the test/silence button on one of these smoke alarms 4 times, and the green LED will rapidly flash continuously, indicating it has entered the transmitting mode (valid time: 60 seconds) .
Step 2: Press the test/silence button on the other smoke alarms twice, and the green LED will slowly flash continuously,indicating it has entered the receiving mode.
-----If pairing is successful: The green LED of these alarms will stop flashing.
-----When it is failure: The green light will continue to flash for 60 seconds, and then the red light will stay on for 2 seconds.
How to disabling the interconnect function

Press the test/silence button on the smoke alarms twice and the green LED will slowly flash continuously still 60 seconds, then ignore it and it will automatic despairing.

How to silence the alarms in network when alarm

If the smoke alarm detects fire, the device will goes into Source/Master smoke alarm sound pattern alarmed, and emits the alarm signal;
When other alarm devices received alarm signal, they will goes into Slave smoke alarm sound pattern, until the Source/Master alarm device stopped alarm; During the unit is alarming, you can find out the Source/Master smoke alarm , press the Test/Silence button to pause all other
interconnected alarms.
Replaced Battery

1. The low battery signal can last for maximum 30 days, please replace the batteries in time to keep it working properly.
2. Battery required: 10-Year Lithium Battery
3. Acceptable brand: Duracell MN1500, Golden Peak LR6, GP GN15A, etc.
4. Correctly install the positive and negative poles of the battery (“+” & “-”)
5. Waste batteries should not be placed into any household waste or recycling bin as all of them have the potential to spark. Check with your Local Authority for recycling advice.
FAQ

Q: How can i place an order?
Please provide the details of your requirements as clear as possible. So we can send you the offer at the first time.
A: For designing or further discussion, it is better to contact us with Skype / email / phone, in case of any delays.
Q: How about the quality of the personal alarm ?
A:We produce every product with good quality materials and fully test three times before shippment. What is more, our quality
areapproved by CE RoHS SGS & FCC, IOS9001, BSCI.

Q: Can i have a sample order?
A: Yes, we welcome sample order to test and check quality. Mixed samples are acceptable.
Q:What is your terms of delivery?
A: We accept EXW, FOB, CFR, CIF, DDU, DDP, etc. You can choose the one which is the most convenient or cost effective for you.

Q: How do you ship the goods and how long does it take arrive?
A:We usually ship by DHL(3-5days), UPS(4-6days), Fedex(4-6days), TNT(4-6days), Air(7-10days), or by sea(25-30days)at your request.


China 3 Year Battery Wireless Interconnected Smoke Detector Fire Alarm Sensor supplier

3 Year Battery Wireless Interconnected Smoke Detector Fire Alarm Sensor

Inquiry Cart 0