Aloka ASU-1010 Ultrasound 4D Probe Repair Motor Control Failures

Brand Name:Aloka
Model Number:ASU-1010
Minimum Order Quantity:1
Delivery Time:1-5 work days
Payment Terms:T/T,Western Union
Price:Negotiable
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou Guangdong China
Address: Room 201, 203, Building C ,No. 26, Ningcai Road, Huangpu District, Guangzhou, China
Supplier`s last login times: within 16 hours
Product Details Company Profile
Product Details

4D Probe Motor Repair Motor Control Failures Aloka ASU-1010


We provide repair service on most common probes, 3D/4D transducers, and Endo/TEE probes.

With 10 years experiences on probe repair, our technical engineer team own the most advanced probe repair processes, which enables us to fix probes from a basic lens fault to 4D /TEE fault.

Once repaired, all probes will go through an extensive testing process ,until reach their optimal condition.





Common ultrasound Probe Damage(Specialty 3D/4D Volume probes)


Common ultrasound probe damageSolutions
Lens cap damageLens cap replacement
Fluid and oil leaksLens cap replacement, oil reservoir repair and replacement
Cable cutsCable patches, possible cable replacement
Inoperative steeringMotor repair
Connector housing electrical damageMinor electrical repairs, pin module replacement
Weak or dead elements, dropouts in an imageArray ball replacement, oil reservoir repair and replacement

Warnings and cautions of ultrasonic probe


The ultrasonic probe is a valuable device. It must be careful in the process of use. Avoid dropping, impact, or abrasion to transducers.

When installing or removing the probe, first switch off the power and then operate it carefully.

Avoid rapid and extreme temperature changes, as well as lengthy exposure to direct sunlight or a strong ultraviolet light source.

Do not use sharp objects to penetrate the acoustic lens.Once the acoustic lens is damaged, the coupling gel is easy to enter the interior of the probe and damage the piezoelectric element.

Do not soak transducer in any liquid above the recommended level as stated in the user manual for your system, please operate according to the manufacturer's instructions, otherwise it will lead to circuit failure or even burn out.

Do not disinfect at high temperature, because the probe is equipped with piezoelectric ceramics, high temperature will weaken the effect.

Before use, carefully check whether the housing and cable are damaged, so as to prevent the probe from high voltage injury.

After the probe is used, the residual coupling gel on the probe must be wiped clean to prevent rats or other animals from gnawing the lens.