reusable Ultrasound Biopsy Needle Guide for Hitachi EUP C715

Brand Name:Hitachi
Model Number:EUP-C715
Minimum Order Quantity:1
Delivery Time:2-4 work days
Payment Terms:T/T, Western Union
Place of Origin:China
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou Guangdong China
Address: Room 201, 203, Building C ,No. 26, Ningcai Road, Huangpu District, Guangzhou, China
Supplier`s last login times: within 16 hours
Product Details Company Profile
Product Details

Reusable Biopsy Needle Guide for SAMSUNG Ultrasound Hitach EUP-C715 Transducer


1. Type:4angles, accepts 14-22 Gauge instruments
2. Fits:hitach EUP-C715
3. Features:stainless steel, reusable, easy to clean and sterilize
4. Professional new one from Chinese factory, precision manufacturing
5. Qualified one in excellent working condition
6. Provide 90 days warranty


Note: Different brands(Aloka/GE//Mindray/Biosound/Toshiba/Sonosite---) are also available, please email for details.



Other Ultrasound Biopsy Needle Guides related to Hitachi that we can offer:


BrandModelAngleApplicative needle
HitachiEUP-U531single angle16,17,18G
HitachiEUP-V33W,EUP-V53W,EUP-CC531single angle16,17,18G
HitachiEUP-C311two angles14-22G
HitachiEUP-C314T,C314G,C324T,C514,C516single angle14-22G
HitachiEUP-C532three angles14-22G
HitachiEUP-C715four angles14-22G
HitachiEUP-L74Mthree angles14-22G
HitachiEUP-B512two angles14-22G
HitachiEUP-L54Mfour angles14-22G

Other Ultrasound Biopsy Needle Guides related to Samsung that we can offer:


BrandModelAngleApplicative needle
Samsung3D4-9single angle16,17,18G
SamsungC1-4two angles14-22G
SamsungC2-6ICthree angles14-22G
SamsungCF4-925-65°16,17,18G
SamsungCS1-4three angles14-22G
SamsungEC4-9IS,EC4-9ES,ER4-9ESsingle angle16,17,18G
SamsungER4-9/10ED,EV4-9/10ED,EVN4-9,ER4-9single angle16,17,18G
SamsungHL5-12EDthree angles14-22G
SamsungL5-13IS,L6-12IS,L7-16IS,L8-15ISthree angles14-22G
SamsungP2-4BAtwo angles14-22G
SamsungV5-9single angle16,17,18G
SamsungVR5-9single angle16,17,18G

Before using for the first time, perform needle path verification to verify system and needle guide relations. To avoid any injury to the patient, please observe the following:


1. Refer to system manual for proper procedure.

2. Before verifying, ensure all parts are in good condition.

3. Ensure the needle guide and the needle have been installed correctly.

4. Use a needle suitable for the biopsy and the needle guide.

5. Use proper needle length to reach target area.

6. Carefully insert the needle to avoid bending.

7. Use a straight, new, sterile needle for each verification procedure to help predict the needle's orientation accurately.

8. The guidelines are only used to indicate the expected path of the needle.

9. Do not use the needle guide if the needle does not follow the intended path.

10. The needle used for this needle path verification must not be used for the actual procedure, and needle guide must be


Disinfecting and Sterilizing Needle Guide


a) High-level disinfect or sterilize the needle guide using 2% glutaraldehyde-based solution.

b) The needle guide can be sterilized by using steam (autoclave) at 132-138°C for 15 to 30 minutes.


Storage and Transportation


Take care and avoid the crash, drop etc.

b) Please store and transport the device in the following environment:

* Store in non-corrosive gas and well-ventilated room

* Ambient temperature: -35℃〜55℃

* Relative humidity: 15%〜95%(no condensation)

* Atmospheric pressure: 700hPa〜1060hPa