GE RAB4-8-RS Ultrasound Probe Repair Dome Original Condition Oil Filling

Brand Name:GE
Model Number:RAB4-8-RS
Minimum Order Quantity:1
Delivery Time:1-5 work days
Payment Terms:T/T,Western Union
Price:Negotiable
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou Guangdong China
Address: Room 201, 203, Building C ,No. 26, Ningcai Road, Huangpu District, Guangzhou, China
Supplier`s last login times: within 16 hours
Product Details Company Profile
Product Details

GE RAB4-8-RS Ultrasound Probe dome Repair Original Condition Oil Filling


The dome is damaged and leaking oil


Suggestion: replace the dome (filling oil)




Other hot GE models we can repair:


GEC1-5-D
GEC1-5-RS
GE4C
GE4C-RS
GE4C-A
GE4C-D
GE4C-SC
GEE8C/E8C-RS
GEE8CS
GERIC5-9-D
GE3CRF-D
GEC1-6-D
GERAB4-8-RS
GERAB2-5-RS
GE6S-RS
GE12L-RS
GE3SC-RS
GEL6-12-RS
GE11L
GE11L-D
GE12L-RS
GE8C
GE3S
GE3S-RS

Common ultrasound Probe Damage(Specialty 3D/4D Volume probes)


Common ultrasound probe damageSolutions
Lens cap damageLens cap replacement
Fluid and oil leaksLens cap replacement, oil reservoir repair and replacement
Cable cutsCable patches, possible cable replacement
Inoperative steeringMotor repair
Connector housing electrical damageMinor electrical repairs, pin module replacement
Weak or dead elements, dropouts in an imageArray ball replacement, oil reservoir repair and replacement



Warnings and cautions of the ultrasonic probe


The ultrasonic probe is a valuable device. It must be careful in the process of use. Avoid dropping, impact, or abrasion to transducers.

When installing or removing the probe, first switch off the power and then operate it carefully.

Avoid rapid and extreme temperature changes, as well as lengthy exposure to direct sunlight or a strong ultraviolet light source.

Do not use sharp objects to penetrate the acoustic lens.Once the acoustic lens is damaged, the coupling gel is easy to enter the interior of the probe and damage the piezoelectric element.

Do not soak transducer in any liquid above the recommended level as stated in the user manual for your system, please operate according to the manufacturer's instructions, otherwise it will lead to circuit failure or even burn out.

Do not disinfect at high temperature, because the probe is equipped with piezoelectric ceramics, high temperature will weaken the effect.

Before use, carefully check whether the housing and cable are damaged, so as to prevent the probe from high voltage injury.

After the probe is used, the residual coupling gel on the probe must be wiped clean to prevent rats or other animals from gnawing the lens.



China GE RAB4-8-RS Ultrasound Probe Repair Dome  Original Condition Oil Filling supplier

GE RAB4-8-RS Ultrasound Probe Repair Dome Original Condition Oil Filling

Inquiry Cart 0