Add to Cart
UVOZ-1200C Ozone Gas Analyzer
The UVOZ-1200 ozone gas analyser calculates the current ozone
concentration by measuring the change in light signal intensity
before and after ozone absorption of UV light. The equipment uses
an advanced dual-light UV light source system with a lamp
intelligent management system, which enables the UV lamp to reach
the measurement state quickly after switching on. It is mainly used
for continuous detection of ozone gas in various industrial
environments, and can also be used to detect ozone gas in operating
pipelines, vessels and other environments.
The ozone analyser has a touch screen operator interface with real
time display of ozone gas concentration, with pressure and
temperature compensation and display, and can be set for automatic
zero time and manual zeroing mode. High concentration (g/Nm3) range
with flow input and real time display of ozone generator output.
Two sets of relay signal outputs are available, allowing the user
to choose between high and low alarm point signal output
connections. The core component adopts UV long life light source
system with high transmittance quartz sheet to ensure the stability
of the zero point and prevent the zero point drift from affecting
the accuracy of the detection concentration. According to the
foreign light cell technology design of pressure-resistant,
impact-resistant independent light cell structure, zero calibration
operation gas flow, pressure, flow rate remains unchanged, to
prevent the impact of airflow on the zero calibration, without
closing the ozone inlet can complete the zero calibration
operation, to ensure that the equipment can be 24 hours a day
continuous operation.
Model | UVOZ-1200 |
Measuring range | 0-200g/Nm3 |
Optional ranges | 0-300g/Nm3, 0-100g/Nm3, 0-50g/Nm3, 0-1000ppm |
Sampling method | positive pressure sampling, negative pressure sampling (optional) |
Display interface | 4.3" touch screen operator interface |
Content interface | Ozone concentration, temperature, pressure |
Display units | g/Nm3, mg/NL, %WT optional |
Display resolution | 0.01g/Nm3 |
Gas flow | 0.5L ± 0.2L/min |
Concentration error | 0.3% FS max |
Linearity error | 0.2% FS max |
Zero point drift | <±0.3%.FS |
Response time | 0.03 s for signal, 0.3 s for display |
Ambient temperature | -20 to 50°C |
Tandem sample aperture | Φ8 (8mm*6mm) (optional) |
Bypass sampling aperture | Φ6 (6mm*4mm) |
Communication method | RS-485 |
Output mode | 4-20mA (active) |
Power supply | AC 110-220V |
Dimensions | 160mm (H) x 260mm (W) x 300mm (D); |
Note | 1mg/L = 1g/m3 = 467PPM. |
Free warranty | 24 months (mainframe sensor) |