Zr-D13D Flue Gas Moisture Analyzer / Flue Gas Measuring Instrument

Brand Name:HiYi
Certification:CE
Model Number:Zr-D13D
Minimum Order Quantity:1
Delivery Time:5-7 work days
Payment Terms:L/C, D/A, D/P, T/T
Contact Now

Add to Cart

Verified Supplier
Location: Beijing Beijing
Address: Room 1302,Yufei Building, 42 Dongzhimenwai Street, Dongcheng District, Postcode:100027 Beijing,China
Supplier`s last login times: within 48 hours
Product Details Company Profile
Product Details
Zr-D13D Flue Gas Moisture Analyzer
OVERVIEW

Principle: Dry wet bulb method

Make the gas flow through the dry and wet bulb thermometers at a certain speed. Calculate the moisture of the exhaust according to the readings of the dry and wet bulb thermometers and the exhaust pressure at the measuring point.

By measuring and collecting the surface temperature of wet bulb and dry bulb, and through the surface pressure of wet bulb and exhaust static pressure and other parameters, the saturated steam pressure at this temperature is derived from the surface temperature of wet bulb, and combined with the input atmospheric pressure, the moisture content of flue gas is automatically calculated according to the formula.

FEATURES

In the equation:

Xsw----Volume percentage of moisture content in exhaust gas, %

Pbc----- Saturated steam pressure when temperature is tb (According to the tb value, it can be found from the water vapor pressure gauge when the air is saturated),Pa

tb---- Wet Bulb Temperature,ºC

tc----Dry Bulb Temperature,ºC

Pb-----Gas pressure passing through the surface of wet bulb thermometer,Pa

Ba-----Atmospheric Pressure,Pa

Ps-----Exhaust static pressure at the measuring point,Pa


> Integrated design, small size, light weight, easy to carry.

> It can not only detect the moisture content of flue gas, but also measure two-way VOCs sampling.

> Bright color touch screen, which can directly read data.

> The pitot tube can be disassembled, moved, and rotated, making it easy to carry and suitable for various types of flue.

> Built in RC humidity sensors, ensure high accuracy, good reliability, and response time less than 30s.

> Read sampling data and historical data automaticly.

> Measurable oxygen content (optional).

> Printing data with external bluetooth printer (optional).

SPECIFICATION

ParameterRangeResolutionError
Sampling flowrate of flue gas(10~200)mL/min1mL/min±2.5%
Dynamic pressure(0~2000) Pa1Pa±2.0%
Static pressure(-30-30) kPa0.01kPa±2.0%
Total pressure(-30-30) kPa0.01kPa±2.0%
Flue gas temperature(0~300)°C0.1°C±3.0°C
Atmospheric pressure(60~130) kPa0.01kPa±0.5kPa
Moisture(0~40)%0.01%VOL±2.0%
O2 content(optional)(0~30)%0.1%±5.0%
Noise60dB(A)
Size(L1455*W360*H275)mm
Host WeightAbout 4kg
Power supplyDC24V/10A
Consumption≤150W