800mm Ziehl-Abegg EC Fan Immersion Cooling Data Center Air Dry Coolers
What's Immersion Cooling?
Also known as liquid submersion cooling. It is the practice of
submerging computer components (or full servers) in a thermally,
but not electrically, conductive liquid (dielectric coolant)
allowing higher heat transfer performance than air and many other
benefits.
Traditionally, air-cooled methods require raised floor systems that
allow for cold air to be pumped to servers via computer room air
conditioners (CRAC). This traditional method proves to be
inefficient when cooling increased compute loads and higher watts
per square foot. The majority of legacy and enterprise data centers
today utilize air-cooled systems.
One item that remains clear is that as servers demand more power
and generate more heat, liquid cooling is emerging as the leader in
more efficient cooling practices. Increasingly, the deployment of
immersion cooling is what separates the data center technology
leaders from the rest of the pack.
Below, we’ve highlighted some of the top benefits of immersion cooling:
Reduce Operating Costs by 50%+
Power reduction by removing the fans from the miners (~18% – 25%)
Removal of supplementary cooling systems (Intake / Exhaust fans, etc. account for another 20% – 25%)
Increase the hash rate of your current equipment
Increase hardware lifespan
Increase the density of miners in your facility
Built in fire protection as our dielectric fluid is non-flammable
Technical parameter of dry coolers
Dry cooler D3 series parameter(fin space 2.1mm)
Type | D3-042- 1X800 | D3-046- 1X800 | D3-051- 1X800 | D3-087- 2X800 | D3-094- 2X800 | D3-103- 2X800 | D3-125- 3X800 | D3-146- 3X800 | D3-153- 3X800 | D3-175- 4X800 | D3-188- 4X800 | ||||||
Capacity | Water | 35℃ outdoor temp. | Inlet | 45℃, | KW | 42.1 | 46.1 | 50.6 | 87.3 | 93.6 | 102.9 | 124.9 | 145.9 | 153.3 | 174.5 | 187.9 | |
outlet | 40℃ | ||||||||||||||||
20% Glycol | Inlet | 45℃ | 40.8 | 45.1 | 49.7 | 84.5 | 91.8 | 100.9 | 119.4 | 143 | 150.4 | 168.9 | 184.3 | ||||
outlet | 40℃ | ||||||||||||||||
Medium | Water flow | M3/h | 7.3 | 8 | 8.8 | 15.2 | 16.3 | 17.9 | 21.7 | 25.4 | 26.6 | 30.3 | 32.7 | ||||
Pressure drop | kPa | 49 | 69 | 97 | 48 | 98 | 93 | 21 | 97 | 89 | 48 | 98 | |||||
Air flow | M3/h | 21454 | 20531 | 19696 | 42906 | 41061 | 39390 | 64364 | 61585 | 59087 | 85811 | 82120 | |||||
Fan motor(400V/3N/50HZ) | W | 1800 | 1800 | 1800 | 3600 | 3600 | 3600 | 5400 | 5400 | 5400 | 7200 | 7200 | |||||
A | 3.8 | 3.8 | 3.8 | 7.6 | 7.6 | 7.6 | 11.4 | 11.4 | 11.4 | 15.2 | 15.2 | ||||||
Fan | No X φ | 1x1 x800 | 1x1 x800 | 1x1 x800 | 1x2 x800 | 1x2 x800 | 1x2 x800 | 1x3 x800 | 1x3 x800 | 1x3 x800 | 2x2 x800 | 2x2 x800 | |||||
Sound pressure level | dB(A) | 50 | 50 | 50 | 51 | 51 | 51 | 53 | 53 | 53 | 54 | 54 | |||||
10m | |||||||||||||||||
Dimension | L | mm | 2000 | 2000 | 2000 | 3800 | 3800 | 3800 | 5600 | 5600 | 5600 | 3800 | 3800 | ||||
W | mm | 1084 | 1084 | 1084 | 1084 | 1084 | 1084 | 1084 | 1084 | 2108 | 2108 | 2108 | |||||
H | mm | 1328 | 1328 | 1328 | 1328 | 1328 | 1328 | 1328 | 1328 | 1328 | 1328 | 1328 | |||||
A | mm | 1728 | 1728 | 1728 | 3528 | 3528 | 3528 | 5328 | 5328 | 5328 | 3528 | 3528 | |||||
B1 | mm | -- | -- | -- | 1764 | 1764 | 1764 | 1776 | 1776 | 1776 | 1764 | 1764 | |||||
B2 | mm | -- | -- | -- | 1764 | 1764 | 1764 | 1776 | 1776 | 1776 | 1764 | 1764 | |||||
B3 | mm | -- | -- | -- | -- | -- | -- | 1776 | 1776 | 1776 | -- | -- | |||||
B4 | mm | -- | -- | -- | -- | -- | -- | -- | -- | -- | -- | -- | |||||
X | mm | 997 | 997 | 997 | 997 | 997 | 997 | 997 | 997 | 997 | 2021 | 2021 | |||||
Inlet φ | mm | 2” | 2” | 2” | 2 1/2” | 2 1/2” | 2 1/2” | 3’ | 3’ | 3’ | 4” | 4” | |||||
Inlet φ | mm | 2” | 2” | 2” | 2 1/2” | 2 1/2” | 2 1/2” | 3’ | 3’ | 3’ | 4” | 4” | |||||
Product weight(empty) | kg | 225 | 233 | 241 | 357 | 373 | 392 | 796 | 527 | 749 | 812 | 1062 |