CE Submerged Cooling Data Center Immersion Cooling Dry Coolers


How does immersion cooling work and what is the impact on the future of data centers?

  • Immersion cooling is a process in which servers and other IT hardware are immersed in non-conductive fluids such as 3M™ Novec™ Engineered Fluids. Heat generated by the electronic components is transferred to the fluid, reducing the need for active cooling components, such as interface materials, heat sinks and fans that are common in air cooling.
  • Data centers will need to improve energy efficiency and reduce size to keep up with the data demand. Liquid immersion cooling in data centers offers a unique opportunity to reduce cooling costs by 95% and reduce data center size by 10x.

Why many large data centers have already moved or are considering the move to immersion cooling?

  1. Save floor space. Compare with traditional forced air cooling way(using precision air conditioner), immersion cooling system will save much floor space. Because no need rack system and no need air conditioner indoor.
  2. Save power. Compare with traditional forced air cooling way(using precision air conditioner), immersion cooling system will save much power. For example, no need to install many air conditioners indoor, then no compressor power consumption. For example, the bitcoin miners no need air cooling fans. Thesewill save power around 18~25%.
  3. Increase hardware lifepan. In immersion, machines operate in a 100% controlled environment with no dust, no temperature of humidity fluctuations, no impurities. This will extend the service life of the mining machine or server. This will also reduce machine maintainance fee.
  4. Increase hashrate of the mining machine.

For immersion cooling system, our dry cooler is the most cost-effective way to remove heat and a necessary component of the immersion cooling system, We designed a full range of immersion optimized dry coolers. From 5kW single fan unit to the V-shaped 48-921kW dry coolers. Made in China, sized to your needs.


Shenglin and Shenglin partner can offer one-stop solution:

For bitcoin mining farm, if use immersion cooling system, Shenglin dry cooler is the most cost-effective way to remove heat and a necessary component of the immersion cooling system, We designed a full range of immersion optimized dry coolers. From 5kW single fan unit to the V-shaped 48-921kW dry coolers. Made in China, sized to your needs.


Like this way:


Some immersion cooling system dry cooler reference:


Country: USA

Application: Bitcoin immersion cooling system

Cooling capacity: 1270kW

Cooling medium: BC-888

Supply power: 415V/3P/60Hz

Fan brand: Ziehl-Abegg


Country: USA

Application: Bitcoin immersion cooling system

Cooling capacity: 171kW

Cooling medium: bitcoin fluid

Supply power: 415V/3P/60Hz

Fan brand: Chinese brand