Close Control Air Conditioner For Nucleic Acid Amplification Testing Station

Feature: integral design, simple and convenient installation and operation, inverter compressor, dual EC fan, PLC high precision constant temperature and humidity control. Non-standard design.


According to the clean operating room design specifications, the clean air conditioning system must have core technical indicators such as constant temperature, constant humidity, fresh air treatment, air purification, and ensuring the positive and negative pressure difference in the controlled area to achieve the design requirements for controlling the concentration of bacteria and reducing the risk of infection. Clean air conditioners have multiple functions such as air purification, transportation, cooling, dehumidification, humidification, heating, heat recovery, and intelligent control, providing users with clean environment system solutions suitable for different purification levels and different working conditions.

Standard DX AHU Technical Paramater:
Unit characteristicsModel: SL-ZKW-( ) DX203040506580100
Cooling capacity 1*kw10.115.320.325.532.338.652.0
Heating capacity 2*kw10.315.720.826.133.539.553.2
Air volume 3*m3/h20003000400050006500800010000
Static air pressure 3*Pa200250300300400400500
power3N-380V-50Hz
Indoor unitSupply air fan 3*TypeEfficient centrifugal fan
kw0.550.751.52.23.03.05.5
Chilled water coil 4*(option)TypeEfficient copper tube and aluminum fin
Flow m3/h1.72.63.54.45.66.68.9
Section length(mm)300300300300300300300
Heater 5*TypeStainless steel tube electric heating/ steam heating coil/hot water heating coil
kw691218242430
Section length(mm)300300300300400400400
Humidifier 5*TypeElectrode type/steam/electrothermic type/wet film
kg/h345881212
Section length(mm)400400400400400400400
Filter 6*TypePrimary filter G4(medium effect F8/ Nanocrystalline carbon filter
NoisedB(A)60606162636365
Overall dimension 7*Length(mm)1800200020002100210022002400
Width(mm)730103010301030114013401340
Height(mm)78878811151115111511151420
Weightkg40180320400580660800
Outdoor unitModel: SL-WL10152025354055
Compressor ATypeHermetic scroll type (Fixed frequency system)
Qty1111122
Input power Akw3.44.86.38.09.812.716.1
Compressor BTypeHermetic scroll type (Inverter system)
Qty1111122
Input power Bkw3.34.66.27.79.712.615.6
Refrigerant 8*TypeR22/R407C/R410A
ModeExternal balance type thermal expansion valve/electronic expansion valve
Noise 9*dB(A)63636464656567
Overall dimensionLength(mm)85085098098098018801880
Width(mm)85085098098098018801880
Height(mm)1080108010801080123410801080
Weightkg130135150180220280320
Connection pipe size 10*Liquid pipe(mm)12.7(9.52)12.7(9.52)12.7(12.7)15.88(12.7)15.88(12.7)15.88*2(12.7*2)15.88*2(12.7*2)
Steam pipe(mm)15.88(12.7)19.05(15.88)19.05(15.88)28.6(22.23)28.6(22.23)22.23*2(19.05*228.6*2(22.23*2)

1. Cooling condition: indoor dry bulb/wet bulb 27/19℃; outdoor dry bulb/wet bulb 35/24℃

2. Heating condition: indoor dry bulb/wet bulb 20/-℃; outdoor dry bulb/wet bulb 7/6℃

3. Air volume, pressure, power in the table is standard parameters. It can be separately designed according to customer`s requirements

4. Chilled water coil as optional parts, according to the customer site requirements configured to double cold source unit.

5. Heater, humidifier, heat recovery device as optional parts, according to the customer requirements configured to the other forms.

6. Unit standard uses G4 level filters, according to the customer requirements configured to the other forms.

7. Unit length does not include the function section .Such as heating section, humidification section. Specific details please consult us.

8. Air cooled split type air conditioning unit without refrigerant leaving the factory, refrigerant models need to be indicated in the order.

9. Noise data is measured 2m in front of the unit, 1.2m high, when cooling under the standard air volume.

11.Inside of bracket is R410A refrigerant type connection pipe diameter, the connection copper pipe between the indoor and outdoor unit should within 35 meters.