High Density Servers And Cryptocurrency Miners Immersion Cooling System
What's Immersion Cooling?
Immersion cooling is an IT cooling practice by which IT components
and other electronics, including complete servers, are submerged in
a thermally conductive dielectric liquid or coolant. Heat is
removed from the system by circulating liquid into direct contact
with hot components, then through cool heat exchangers. Fluids
suitable for immersion cooling have very good insulating properties
to ensure that they can safely come into contact with energized
electronic components.
Benefits of Immersion Cooling:
Reduce Operating Costs by 50%+ | Power reduction by removing the fans from the miners (~18% – 25%) | Increase the density of miners in your facility |
Removal of supplementary cooling systems (Intake / Exhaust fans, etc. account for another 20% – 25%) | Increase the hash rate of your current equipment | Built in fire protection as our dielectric fluid is non-flammable |
Increase hardware lifespan | Increase the density of miners in your facility | Immersion cooling systems do not require chillers, CRAC units, raised flooring, etc Many more! |
However, if you need the whole immersion cooling system, our USA partner will help you.
Dry cooler principle
Dry cooler provide a smart way to take advantage of free cooling
when surrounding temperature allows for it. They are made with
inner grooved copper tubes or stainless steel tube and corrugated
aluminum fins, resulting in a combination of compact dimensions and
high capacity.
Dry cooler can be easily integrated with liquid-cooled plate heat
exchangers, especially in free cooling systems.
Dry coolers were designed to achieve an optimized exchange of
thermal energy between air and a refrigerant or fluid. In order for
dry cooler to work, the air temperature needs to be cooler than
water in the system. To cool the system liquid, hot process liquid
flows through the dry cooler tubes. The liquid is then cooled by
the relatively cold ambient air that is forced through the coil.
The core of our air heat exchangers is the fin coil, built from a
circuit of interconnected tube serpentines and fins to increase the
heat exchanging surface.products can be selected for example for
ambient temperature of 27°C instead of 32°C thus obtaining a great
reduction of product dimensions.
Technical parameter of Shenglin dry cooler
Dry cooler D3 series parameter(fin space 2.1mm)
Type | D3-042- 1X800 | D3-046- 1X800 | D3-051- 1X800 | D3-087- 2X800 | D3-094- 2X800 | D3-103- 2X800 | D3-125- 3X800 | D3-146- 3X800 | D3-153- 3X800 | D3-175- 4X800 | D3-188- 4X800 | ||||||
Capacity | Water | 35℃ outdoor temp. | Inlet | 45℃, | KW | 42.1 | 46.1 | 50.6 | 87.3 | 93.6 | 102.9 | 124.9 | 145.9 | 153.3 | 174.5 | 187.9 | |
outlet | 40℃ | ||||||||||||||||
20% Glycol | Inlet | 45℃ | 40.8 | 45.1 | 49.7 | 84.5 | 91.8 | 100.9 | 119.4 | 143 | 150.4 | 168.9 | 184.3 | ||||
outlet | 40℃ | ||||||||||||||||
Medium | Water flow | M3/h | 7.3 | 8 | 8.8 | 15.2 | 16.3 | 17.9 | 21.7 | 25.4 | 26.6 | 30.3 | 32.7 | ||||
Pressure drop | kPa | 49 | 69 | 97 | 48 | 98 | 93 | 21 | 97 | 89 | 48 | 98 | |||||
Air flow | M3/h | 21454 | 20531 | 19696 | 42906 | 41061 | 39390 | 64364 | 61585 | 59087 | 85811 | 82120 | |||||
Fan motor(400V/3N/50HZ) | W | 1800 | 1800 | 1800 | 3600 | 3600 | 3600 | 5400 | 5400 | 5400 | 7200 | 7200 | |||||
A | 3.8 | 3.8 | 3.8 | 7.6 | 7.6 | 7.6 | 11.4 | 11.4 | 11.4 | 15.2 | 15.2 | ||||||
Fan | No X φ | 1x1 x800 | 1x1 x800 | 1x1 x800 | 1x2 x800 | 1x2 x800 | 1x2 x800 | 1x3 x800 | 1x3 x800 | 1x3 x800 | 2x2 x800 | 2x2 x800 | |||||
Sound pressure level | dB(A) | 50 | 50 | 50 | 51 | 51 | 51 | 53 | 53 | 53 | 54 | 54 | |||||
10m | |||||||||||||||||
Dimension | L | mm | 2000 | 2000 | 2000 | 3800 | 3800 | 3800 | 5600 | 5600 | 5600 | 3800 | 3800 | ||||
W | mm | 1084 | 1084 | 1084 | 1084 | 1084 | 1084 | 1084 | 1084 | 2108 | 2108 | 2108 | |||||
H | mm | 1328 | 1328 | 1328 | 1328 | 1328 | 1328 | 1328 | 1328 | 1328 | 1328 | 1328 | |||||
A | mm | 1728 | 1728 | 1728 | 3528 | 3528 | 3528 | 5328 | 5328 | 5328 | 3528 | 3528 | |||||
B1 | mm | -- | -- | -- | 1764 | 1764 | 1764 | 1776 | 1776 | 1776 | 1764 | 1764 | |||||
B2 | mm | -- | -- | -- | 1764 | 1764 | 1764 | 1776 | 1776 | 1776 | 1764 | 1764 | |||||
B3 | mm | -- | -- | -- | -- | -- | -- | 1776 | 1776 | 1776 | -- | -- | |||||
B4 | mm | -- | -- | -- | -- | -- | -- | -- | -- | -- | -- | -- | |||||
X | mm | 997 | 997 | 997 | 997 | 997 | 997 | 997 | 997 | 997 | 2021 | 2021 | |||||
Inlet φ | mm | 2” | 2” | 2” | 2 1/2” | 2 1/2” | 2 1/2” | 3’ | 3’ | 3’ | 4” | 4” | |||||
Inlet φ | mm | 2” | 2” | 2” | 2 1/2” | 2 1/2” | 2 1/2” | 3’ | 3’ | 3’ | 4” | 4” | |||||
Product weight(empty) | kg | 225 | 233 | 241 | 357 | 373 | 392 | 796 | 527 | 749 | 812 | 1062 |
Our workshop:
Some immersion cooling system dry cooler reference:
Country: USA Application: Bitcoin immersion cooling system Cooling capacity: 1270kW Cooling medium: BC-888 Supply power: 415V/3P/60Hz Fan brand: Ziehl-Abegg | Country: USA Application: Bitcoin immersion cooling system Cooling capacity: 171kW Cooling medium: bitcoin fluid Supply power: 415V/3P/60Hz Fan brand: Chinese brand |