Product Details

V-type Evaporative Cooling System Air Cooler Dry Cooler For Industry


In adiabatic cooling pad systems, cool pads are placed in special sheet metal assemblies which are mounted in front of fin block. With the aid of the pump, water wets the pads from the upper part of the pad system. The outside air, which is dry and hot, is pre-cooled by passing it through wet cooling pads. The temperature of the air that contact with the wet cooling pads is approximated to the wet thermometer temperature. The water does not contact directly with the fins. Thus fins lifetime is longer than the direct spraying systems. Also pads prevent contamination of fins. Since the microorganisms, minerals and similar parts do not mix into the air during the evaporation phase of water, the working principle is completely healthy. The system ensures that product efficiency can be increased with minimum water consumption.


Features of dry cooler

High efficiency heat exchanger: capacity designs for maximizing the heat transfer relative to the energy consumption of the fan. Tube and tube coupling design for low pressure drop in the coil on the media sides(maximum 100KPa at water designing condition). Our thermodynamic and aerodynamic designing software is long year tested and proved in Germany
Fan: only choose low specific energy consumption fans. Fan nozzle designs for maximum air flow and air throw.Our fans from the world`s leading manufacturer are practically proved to be reliable in operation and long lasting. Motor: protection class IP 54 and insulation class F. Air separator for each fan.
We facilitate you to have a long lasting and low maintainance operation. Durable material and rigid enclosure with hard gloss powder coated finish. Protective enclosure for both manifolds and U-bends. Unit design for outdoor installation. 100% leakage tested at 31bar.

Options

Coil design refrigerant: water, oil, glycol.Multiple circuits.
Sub-cooling circuits.Stainless steel or aluminum casing.
Coated aluminum or copper fins.Explosion proof motor.
Customized fin spacing.

Technical parameter

Dry cooler D2 series parameter(fin space 2.1mm)

Type

D2-148-

4x630

D2-166-

4x630

D2-175-

4x630

D2-228-

6x630

D2-250-

6x630

D2-276-

6x630

D2-310-

8x630

D2-343-

8x630

D2-364-

8x630

D2-392-

10x630

CapacityWaterKW147.99165.85175.21227.85250.42276.53309.85342.73364.07391.99
20% Et. GlycolKW142.42161.57170.91219.09244.69270.22301.18333.55354.64383.3
Air flowM3/h764597434172134114686111511108188152911148675144255191136
FanNo. X φ2x2x6302x2x6302x2x6302x3x6302x3x6302x3x6302x4x6302x4x6302x4x6302x5x630
Fan motorA20.420.420.430.630.630.640.840.840.851
400/3N/50HZ
Sound pressure leveldB(A)10m64646466666667676768
DimensionLmm2186218621863250325032504250425042505250
Hmm1874187418741874187418741874187418741874
Dmm2100210021002100210021002100210021002100
D1mm2000200020002000200020002000200020002000
L1mm963963963963963963963963963963
L2mm1000100010001000100010001000100010001000
L3mm1963196319632963296329633963396339634963
Connections inlet φmm2XDN502XDN652XDN652XDN652XDN802XDN802XDN802XDN802XDN1002XDN100
Connections onlet φmm2XDN502XDN652XDN652XDN652XDN802XDN802XDN802XDN802XDN1002XDN100
Product weight(empty)kg7698118531134119712611498158916731864

Advantages and disadvantages

Pros:


- High build quality by necessity

- Up to 98% reduction in cooling power

- Long life fluid (20 years)

- High cooling capacity (4kw per liter)

- Equipment is dry and clean when removed

- Fairly simple plumbing

- Excellent scaling

Cons:


- Not ideal at small scales

- Control costs are the same for 250kW and 10kW

- Controls are complex and expensive

- Cannot use HDDs

- Tanks must be stainless

- Fluids leak easily so quality control must be tightly adhered t


Some reference:


Country: USA

Application: Bitcoin immersion cooling system

Cooling capacity: 1270kW

Cooling medium: BC-888

Supply power: 415V/3P/60Hz

Fan brand: Ziehl-Abegg


Country: USA

Application: Bitcoin immersion cooling system

Cooling capacity: 171kW

Cooling medium: bitcoin fluid

Supply power: 415V/3P/60Hz