Two Phase Liquid Cooling Immersion Cryptocurrency Cooler

Brand Name:Shenglin
Certification:CE
Model Number:SHSL-D1 Series
Minimum Order Quantity:1
Delivery Time:30~35 days
Payment Terms:T/T, Western Union
Contact Now

Add to Cart

Verified Supplier
Location: Shanghai Shanghai China
Address: Room B321, Building No.1, No. 619, Longchang Road, Yangpu District, Shanghai,China
Supplier`s last login times: within 48 hours
Product Details Company Profile
Product Details

Two-phase Liquid Cooling Liquid Immersion Cooling Systems For Cryptocurrency Mining Farms


What's Immersion Cooling?

Also known as liquid submersion cooling. It is the practice of submerging computer components (or full servers) in a thermally, but not electrically, conductive liquid (dielectric coolant) allowing higher heat transfer performance than air and many other benefits.

Why many large data centers have already moved or are considering the move to immersion cooling?


1. Up to 25% increase in power efficiency
2. Up to 80% cost reduction
3. Up to 60% hashrate increase
4. 50%+ equipment lifespan.

Introduction of Two-phase Liquid Cooling:

The cooling liquid undergoes a phase change in the process of circulating heat dissipation. The cooling liquid takes away the heat from the server and then undergoes a phase change gasification. The gaseous cooling liquid is condensed by the condenser and becomes liquid again and returns to the liquid cooling tank; the cooling liquid can use 3M electronics The boiling point of the coolant FC-72 and FC-72 is above 50℃.
In this case, the temperature of the water in the condensing coil does not need to be too low. The use of a dry cooler can meet the heat exchange requirements and take away the heat.
The two-phase liquid cooling has a high heat transfer efficiency due to the phase change of the electronic cooling liquid.
The disadvantage is that during this phase change, the electronic fluorinated liquid will escape during the vaporization process, so there is a certain degree of tightness of the container. However, it should not be too sealed to prevent the cooling system from being interrupted and the cylinder explosion event, so certain safety facilities need to be set up.

Technical parameter

Dry cooler D1 series parameter (fin space 2.1mm)

Type

D1-005-

1x350

D1-006-

1x350

D1-007-

1x350

D1-009-

1x450

D1-011-

1x450

D1-013-

1x450

D1-014-

1x500

D1-017-

1x500

D1-020-

1x500

CapacityWater35℃ outdoor temp.Inlet45℃KW4.895.96.839.3910.9913.3314.3217.0119.8
outlet40℃Y
20% GlycolInlet45℃4.725.696.698.910.6113.0513.9116.1119.29
outlet40℃Y
MediumWater flowM3/h0.851.031.21.631.912.32.533.5
Pressure dropkPa363158254080506040
Air flowM3/h282827122492619958275225846981687601
Y
Fan motorPhase111333333
W140140140540540540830830830
Y
A0.60.60.61.11.11.11.451.451.45
Y
FanNo X φ1x1x3501x1x3501x1x3501x1x4501x1x4501x1x4501x1x5001x1x5001x1x500
Sound pressure leveldB(A)313131434343494949
Y10m
DimensionLmm870870870102010201020122012201220
Wmm525525525625625625825825825
Hmm797797797820820820870870870
Amm690690690840840840104010401040
Bmm------------------
Cmm------------------
Dmm490490490490490490490490490
Inlet φmm3/4”3/4”3/4”1”1”1”1-1/4”1-1/4”1-1/4”
Inlet φmm3/4”3/4”3/4”1”1”1”1-1/4”1-1/4”1-1/4”
Product weight(empty)kg384248556067758291

Note: Standard SHSL-D1 dry cooler is vertical air discharge, for horizontal air discharge please add “H” in nomenclature, for excmple:SHSL-D1-005H-1X350


Some data center cooling reference:


For data center cooling:

Country: Mongolia

Application: match with precision air conditioner

Cooling capacity: 17.6kW

Cooling medium: 34% ethylene glycol

Supply power: 400V/3P/50Hz

Fan brand: Ziehl-Abegg

Country: Russia

Application:data center cooling

Cooling capacity: 763kW

Cooling medium: water

Supply power: 380V/3P/50Hz

Fan brand: Ziehl-Abegg



The immersion cooling system diagram by dry cooler/dry cooling tower:

China Two Phase Liquid Cooling Immersion Cryptocurrency Cooler supplier

Two Phase Liquid Cooling Immersion Cryptocurrency Cooler

Inquiry Cart 0