Power Plant Data Center Multiple Circuits Industrial Dry Cooler

Brand Name:Shenglin
Certification:CE and RoHs
Model Number:D1 Series
Minimum Order Quantity:1
Delivery Time:35~40 days
Payment Terms:T/T, Western Union, L/C
Contact Now

Add to Cart

Verified Supplier
Location: Shanghai Shanghai China
Address: Room B321, Building No.1, No. 619, Longchang Road, Yangpu District, Shanghai,China
Supplier`s last login times: within 48 hours
Product Details Company Profile
Product Details

Power Plant and Data Center Cooling Dry Cooling System Multiple Circuits Heat Exchanger Coil


Why many large data centers have already moved or are considering the move to immersion cooling?


1. Save floor space. Compare with traditional forced air cooling way(using precision air conditioner), immersion cooling system will save much floor space. Because no need rack system and no need air conditioner indoor.

2. Save power. Compare with traditional forced air cooling way(using precision air conditioner), immersion cooling system will save much power. For example, no need to install many air conditioners indoor, then no compressor power consumption. For example, the bitcoin miners no need air cooling fans. Thesewill save power around 18~25%.

3. Increase hardware lifepan. In immersion, machines operate in a 100% controlled environment with no dust, no temperature of humidity fluctuations, no impurities. This will extend the service life of the mining machine or server. This will also reduce machine maintainance fee.

4. Increase hashrate of the mining machine.

For immersion cooling system, our dry cooler is the most cost-effective way to remove heat and a necessary component of the immersion cooling system, We designed a full range of immersion optimized dry coolers. From 5kW single fan unit to the V-shaped 48-921kW dry coolers. Made in China, sized to your needs.


Features

High efficiency heat exchanger: capacity designs for maximizing the heat transfer relative to the energy consumption of the fan. Tube and tube coupling design for low pressure drop in the coil on the media sides(maximum 100KPa at water designing condition). Our thermodynamic and aerodynamic designing software is long year tested and proved in Germany
Fan: only choose low specific energy consumption fans. Fan nozzle designs for maximum air flow and air throw.Our fans from the world`s leading manufacturer are practically proved to be reliable in operation and long lasting. Motor: protection class IP 54 and insulation class F. Air separator for each fan.
We facilitate you to have a long lasting and low maintainance operation. Durable material and rigid enclosure with hard gloss powder coated finish. Protective enclosure for both manifolds and U-bends. Unit design for outdoor installation. 100% leakage tested at 31bar.

Options

Coil design refrigerant: water, oil, glycol.Multiple circuits.
Sub-cooling circuits.Stainless steel or aluminum casing.
Coated aluminum or copper fins.Explosion-proof motor.
Customized fin spacing.

Technical parameter

Dry cooler D1 series parameter(fin space 2.1mm)

Type

D1-005-

1x350

D1-006-

1x350

D1-007-

1x350

D1-009-

1x450

D1-011-

1x450

D1-013-

1x450

D1-014-

1x500

D1-017-

1x500

D1-020-

1x500

CapacityWater35℃ outdoor temp.Inlet45℃,KW4.895.96.839.3910.9913.3314.3217.0119.8
outlet40℃Y
20% GlycolInlet45℃4.725.696.698.910.6113.0513.9116.1119.29
outlet40℃Y
MediumWater flowM3/h0.851.031.21.631.912.32.533.5
Pressure dropkPa363158254080506040
Air flowM3/h282827122492619958275225846981687601
Y
Fan motorPhase111333333
W140140140540540540830830830
Y
A0.60.60.61.11.11.11.451.451.45
Y
FanNo X φ1x1x3501x1x3501x1x3501x1x4501x1x4501x1x4501x1x5001x1x5001x1x500
Sound pressure leveldB(A)313131434343494949
Y10m
DimensionLmm870870870102010201020122012201220
Wmm525525525625625625825825825
Hmm797797797820820820870870870
Amm690690690840840840104010401040
Bmm------------------
Cmm------------------
Dmm490490490490490490490490490
Inlet φmm3/43/43/41111-1/41-1/41-1/4
Inlet φmm3/43/43/41111-1/41-1/41-1/4
Product weight(empty)kg384248556067758291

Application:

Industrial field: process engineering, heat / power plant, power generation, chemical industry, air conditioning chiller, heat transformer, smelting, etc.. It is suitable for all equipment which needs heat dissipation and is installed in the open air.


Reference:

Dry cooler case
Case 1: used in chemical plant.

Case 2: used in chemical plant. Refrigerant: ethylic acid(flow: 372 ton/h)


Case 3: used in communication station as air conditioner outdoor unit in China.

Case 4: used in communication station as air conditioner outdoor unit

For data center coolingCountry: Mongolia
Application: match with precision air conditioner
Cooling capacity: 17.6kW
Cooling medium: 34% ethylene glycol
Supply power: 400V/3P/50Hz
Fan brand: Ziehl-Abegg
Country: Russia
Application:data center cooling
Cooling capacity: 763kW
Cooling medium: water
Supply power: 380V/3P/50Hz
Fan brand: Ziehl-Abegg
For power plantCountry: Hongkong
Application: power plant
Cooling capacity: 363kW
Cooling medium: water
Supply power: 415V/3P/50Hz
Fan brand: Chinese brand
Country: Russia
Application: power plant.
Cooling capacity: 180kW
Cooling medium: water
Supply power: 380V/3P/50Hz
Fan brand: Chinese brand

How to Oder your Own Type of Dry Cooler?


Tell Shenglin the datas as following:
A. Required electrolyte inlet temperature
B. Required electrolyte​ outlet temperature
C. Electrolyte​ flow
D. Ambient temperature
E. Supply power(voltage-Hz-phase)
G. Additional requirements


China Power Plant Data Center Multiple Circuits Industrial Dry Cooler supplier

Power Plant Data Center Multiple Circuits Industrial Dry Cooler

Inquiry Cart 0