Closed Circuit System Free Cooling Fluid Cooler With Spray Water System

Brand Name:Shenglin
Certification:CE
Model Number:H*FD Series Double Rows Fans
Minimum Order Quantity:1
Delivery Time:35~40days
Payment Terms:T/T, Western Union
Contact Now

Add to Cart

Verified Supplier
Location: Shanghai Shanghai China
Address: Room B321, Building No.1, No. 619, Longchang Road, Yangpu District, Shanghai,China
Supplier`s last login times: within 48 hours
Product Details Company Profile
Product Details

Closed Circuit System Free Cooling Type Fluid Cooler With Spray Water System


What is closed-loop dry cooling system?


The strength of a closed-loop dry cooling system is that the unit is very simple and relatively easy to install. The energy requirements are relatively low and it is easily controlled. Maintenance is normally low requiring only periodic inspection, lubrication, and testing of the fluid.


The weakness of a closed-loop dry cooling system is that it is dependent on the atmospheric dry bulb. For example, if your location’s design dry bulb is 100 F in the summer and your equipment requires 90 F coolant; at best the system can only supply around 105 to 110 F coolant to the load. In this case you would need supplemental cooling to get the coolant temperatures down to 90 F.


The closed-loop dry cooling system also requires free clear air to work efficiently. This means that the fluid cooler must be placed in a location that is not affected by the prevailing winds, not too close to a building that will allow the warm exhaust air from the fluid cooler to be recirculated back to the fluid cooler, and finally not in a location that has heavy concentrations of dust, dirt, leaves, seeds, etc.


Many times the best location for the fluid cooler is on the roof. Since the fluid cooler is located outside the coolant must also have a concentration of some type of glycol to prevent freezing if your location has a design dry bulb in the winter that dips below freezing. If the location is very cold, the concentration of glycol may need to be significant to prevent freezing. Glycol concentrations as they increase begin to reduce the rate of heat transfer. For example, if you need 50% ethylene glycol concentration with water the heat exchanger equipment and the flow/pressure of the coolant will need to increase to adjust for the glycol concentration. Larger fluid coolers and pumps will increase the cost of the system over those with lesser concentrations of Glycol/water. This cannot be prevented in colder climates.


Dry fluid cooler features:

Air discharge direction
Performance ranges

Cooling capacity: from 5 to 649 kw

Air volume: from 2828 to 263503 m3/h

Sound pressure level: from 31 to 69 dB A(10m)

Dry coolers:customized on demand

High efficiency heat exchanger

Capacity designs for maximizing the heat transfer relative to the energy consumption of the fan.

Tube and tube coupling design for low pressure drop in the coil on the media sides(maximum 100KPa at water designing condition).

Our thermodynamic and aerodynamic designing software is long year tested and proved in Germany

Fan

Only choose low specific energy consumption fans.

Fan nozzle designs for maximum air flow and air throw.

Our fans from the world`s leading manufacturer are practically proved to be reliable in operation and long lasting.

Motor: protection class IP 54 and insulation class F.

Voltage:400V/3N/50Hz

Air separator for each fan.

TestingHeat exchangers are supplied clean and tested at a pressure of 30 bars
Options

Coil design refrigerant: water, oil, glycol.

Multiple circuits.

Sub-cooling circuits.

Stainless steel or aluminum casing.

Coated aluminum or copper fins.

Explosion ploof motor.

Customized fin spacing.



Fluid Cooler Technical Paraments


Flat series — Double rows fans

H*FD*91Fan Dim
mm
*H*FD491H*FD691H*FD89H*FD1091H*FD1291H*FD1491H*FD1691H*FD1891
Rated Capacities (kW) Heat Exchange Surface (㎡)
Fluid Coolers910D237kW-1632kW 454㎡-4903㎡ (Water/Ta25℃/Tin40℃/Tout35℃)
Freon Condensers910F285kW-1632kW 454㎡-4903㎡ (R404A/Ta35℃/Tk50℃)
Ammonia Condensers910A151kW-1709kW 263㎡-5696㎡ (NH3/Ta35℃/Tk50℃)
Gas Coolers910G156kW-1929kW 358㎡-3859㎡ ( CO2/Tair32℃/Tin113℃/P94Bar/Tout34℃)
Oil Coolers910O174kW-2212kW 454㎡-4903㎡ (OIL ISO VG 46/Ta35℃/Tin85℃/Tout60℃)
Fan Model910ECW3G910KU2503 (2.55kW) or FN091-ZIQ.GL.V5P1 (3.2kW)
910ACW6D910GB0101 (2.02kW) or FN091-SDS.6N.V7P2 (1.85kW)
No of Fans4681012141618
Overall Dimensions910Lenth-134804980648079809480109801248013980
Lenth-2408058807680948011280130801488016680
Width2265
Height1740 (Including 800Leg)



Options

Coil design refrigerant: water, oil, glycolMultiple circuits
Sub-cooling circuitsStainless steel or aluminum casing
Coated aluminum or copper finsExplosion proof motor
Customized fin spacing

EC Fan


Shenglin dry cooler selection software example:


How to design a dry cooler?


Tell Shenglin the datas as following:
A. Required electrolyte inlet temperature?
B. Required electrolyte​ outlet temperature?
C. Electrolyte​ flow?
D. Ambient temperature?
E. Supply power(voltage-Hz-phase)
G. Any other requirements ?


Reference:

For data center coolingCountry: Mongolia
Application: match with precision air conditioner
Cooling capacity: 17.6kW
Cooling medium: 34% ethylene glycol
Supply power: 400V/3P/50Hz
Fan brand: Ziehl-Abegg
Country: Russia
Application:data center cooling
Cooling capacity: 763kW
Cooling medium: water
Supply power: 380V/3P/50Hz
Fan brand: Ziehl-Abegg
For power plantCountry: Hongkong
Application: power plant
Cooling capacity: 363kW
Cooling medium: water
Supply power: 415V/3P/50Hz
Fan brand: Chinese brand
Country: Russia
Application: power plant.
Cooling capacity: 180kW
Cooling medium: water
Supply power: 380V/3P/50Hz
Fan brand: Chinese brand