Max 60 dB UVC lights Transplant Department Air Purifier


Classification of EnvironmentMKJ4000-S4
Environment Class I≤100 m3
Environment Class II≤250 m3
Environment Class III≤500 m3

Eliminating ratesMKJ4000-S4

Eliminating rate of Klebsiella pneumoniae

(1h, 30m3 Experimental chamber), %

100%

Eliminating rate of Aspergillus Niger

(1h, 30m3 Experimental chamber), %

100%

Eliminating rate of Staphylococcus Albus

(1h, 30m3 Experimental chamber), %

100%

Extinction rate of natural bacteria

(1h, 60m3 Experimental chamber), %

99.85%

Eliminating rate of H3N2 virus

(20min, 10m3 Experimental chamber), %

99.99%

Competitive Advantage


. Medical-grade HEPA filter combined with short-wave ultraviolet light
· Removal of 100% of Staphylococcus albicans and Aspergillus niger PM0.5 at tthe air outlet
· Removal of 100% of particles Large airflow velocity 5000 m3/h
· Applicable room volume 250 cubic meters
· low noise max. 60 dB operating power max 420 w
· Strong ultraviolet radiation intensity
. Human and machine coexist
· convenient to move


Alpha pure system and alpha clean control system are adopted to achieve high isolation of ultra-fine particles through polar depolarizer HEPA filtration membrane. Gaseous pollutants are effectively removed through molecular sieve technology. Rapid sterilization is realized through accurate flow distribution of fluid power and high-energy light ions.


Specifications


Technical parameters of MKJ4000-S4
Airflow rate5000m3/h
Klebsiella pneumoniae sterilization rate100%
Aspergillus Niger sterilization rate100%
Sterilization rate of Staphylococcus albus100%
Natural bacteria death rate99.85%
H3N2 influenza virus killing rate99.99%
Purification rate of PM0.5 for one pass100% (on-site inspection)
Dimensions (L×W×H)800×530×1980mm
Input powerMax 420W, 3 levels
NoiseMax 60dB (A), 3 levels
Product N. W180 kg
Product G. W215 kg
Voltage and Frequency220V/50Hz

Applications

Main applicationsRespiratory unit, ICU, Emergency unit, Transplantation unit, CT room, Fever clinic unit, Blood wards, Burn wards, Neonatal rooms
Environment Class ILaminar flow operation room/ward
Environment Class IIICU/Hematological/Burn/Bone Marrow Transplant/Obstetric and Gynecologic/Catheter/Neonatal/Organ Transplant room/ward
Environment Class IIIGeneral/Pediatric/Rooming-in/Gynecologic examination/Treatment/Injection/Dressing/Blood Transfusion/Hemodialysis center/Emergency/Laboratory/Infectious Diseases room/ward
Public placesThe bank, Kindergarten, Movie theaters, fitness halls, clubs, massage rooms, bars, cafes etc
Home careCare home such as Asthma, Rhinitis, Dust mites, and Pollen allergies populations/ People with weakened immunity such as major postoperative, hemopathy, Chemoradiotherapy patient/ People suffering from respiratory diseases (Asthma, COPD)/ People with allergies (Pollen allergy, allergic rhinitis, allergic dermatitis)/ Gestational woman, children, the aged etc

FAQ

Q: Are you a manufacturer or trading company?

A: Manufacturer.


Q: Where is the production base?

A: Tongxiang City of Zhejiang Province. Marketing center located in Xuhui District of Shanghai.


Q: What cooperation mode we could consider?

A: OBM service. We are seeking for a strategic agent or distributors in each country.


Q: What’s your main products?

A:We are dedicated to three series and five products, which are Ekeair air sterilizer MKJ4000-S1, MKJ4000-S2, MKJ4000-S4, Ekeair air sterilizer MKJ-A1, Ekeair air quality monitor SC01.


Q: What is your sole agent policy?

A: An exclusivity agreement would be considered in order to specify trial order number, first and following stage of purchase number, marketing period, sales training before marketing etc.


Q: What is your distribution policy?

A: A distribution agreement would be considered in order to specify trial order number and other conditions.


Q: What about applications?

A: Ekeair air sterilization is suitable for those with high requirements for air quality, such as inpatient, fever clinic, CT room, Respiratory room etc. Ekeair has played an important role in helping with fighting against Covid-19’s bioaerosol.


OBM services:

  • Design, Research & Development, Production of Ekeair brand air sterilization
  • Training of sales, technical, aftersales to agents or distributors in each region.
  • Supports of product marketing to agents or distributors in each region.
  • Supports of aftersales to agents or distributors in each region.
China Max 60 DB Transplant Department True Hepa Medical Air Cleaners supplier

Max 60 DB Transplant Department True Hepa Medical Air Cleaners

Inquiry Cart 0