Ductless Chemical Fume Hood Portable Ductless Fume Hood Self Contained Ductless Fume Cupboard Laboratory Carbon Filter
Ductless fume hoods by GCC
Simple use and safe operation:
The temperature and humidity monitoring system, the temperature and
humidity of the operating area in real time, the alarm value can be
set up
Fan monitoring system, controlling the switch of the fan,
monitoring the operating status of the fan, the fans fail to call
the police, the wind speed can be adjusted.
Facial air detection system: Set the surface wind speed alarm value
to display the current operation of the facial air speed, detect
the operating status, and timely remind users to adjust the fans
speed, and more effectively control the toxic substances without
leakage.
Filter saturation detection system: Set the saturation alarm value
of the filter, corresponding VOC concentration level, online
monitoring the saturation state of the filter, and remind users to
replace the filter in time to ensure product safety.
Automatic control system, automatically adjust the wind speed,
ensure that the facial air speed stabilizes at 0.4 ~ 0.6m/s when
the machine is running
Following the standards of JG/T385-2012 in China's industry
standards, the harmful gas emission after filtration is in line
with GBZ2.2-2007, filtering efficiency <1%TWA value, ≤0.5ppm,
and facial air speed 0.4-0.6m/s.
The modular filtration system can achieve the corresponding filter
for different substances such as gas, powder, etc., and the effect
is better.
Scope of application:
The constant temperature and constant pressure laboratory,
pharmaceutical GMP laboratory, sample ratio and weighing, solvents
cleaning and welding, pre -treatment of samples, chromatography
laboratories, high -efficiency teaching and classroom
demonstrations, clean rooms, forensic physics, laboratory, etc.
It can be used for stirring, liquid, pistol, weighing, rotation,
mixing, ultrasonic cleaning, teaching demonstration, infrared
analyzer, enzyme target, microwave anti -solution, high -efficiency
liquid chromatography, COD experiment, and so on.
Air Flow Pattern
Exhaust Principle
1. Dirty room air is drawn into the front of the fume hood.
2. Room air mixes with potentially contaminated air from chamber
and is pulled upward by the bulding exhaust.
3. Air split at back of hood increases exhaust and reduces turbulence.
4. Contaminated air drawn from fume hood by building exhaust fan
and leaves through air stacks on room
Fume Hood Parameters
Item | GCC-FH-1200 | GCC-FH-1500 | GCC-FH-1800 |
Internal Size | L1000*W700*H2350mm | L1300*W700*H2350mm | L1600*W700*H2350mm |
External Size | L1200*W800*H700mm | L1500*W800*H700mm | L1800*W800*H700mm |
Wind Speed | 0.3~0.8m/s | ||
Noise | <65dB | ||
Air Flow | 1200m³/h | 1800m³/h | 2300m³/h |
Efficiency | 99.99%@0.3μm | ||
Voltage | 220V/50Hz |