Standard IEC60947-2 10KA 415V 2P AC Circuit Breaker

Brand Name:FEEO
Certification:CE/CCC/RoHS
Model Number:FE-125
Minimum Order Quantity:1PC
Delivery Time:7days
Payment Terms:L/C, T/T, Western Union
Contact Now

Add to Cart

Active Member
Address: Keaisi Road, Xiangyang Industrial zone , Yueqing, Zhejiang,China.
Supplier`s last login times: within 48 hours
Product Details Company Profile
Product Details

FE-125 IEC60947-2 AC 415V 2P 10KA Minature Circuit Breaker


FE-125 high breaking capacity circuit breaker is used for AC 50/60HZ, single-pole 230V or two, three, four-pole 415V

circuit for protecting the circuit that overload and short circuit may take place. It can be used in lighting and electric motor

distribution system. Mean while it is applicable to an unfrequented switch over the electric apparatus and lighting circuit

under normal condition. Breaking capacity is up to standard of IEC60947-7 10KA.


Specifications


Rated Voltage230V/415V AC
Rated Current63, 80, 100, 125 A
Characteristic CurveB,C,D
No of Pole1p ,2p,3p,4p
Electrical Life6000 times
Mechanical Life20000 times (C.O)
Weight1P2P3P4P
150300450600

Dimensions


Over current tripping characteristic

ItemRated Current(A)Initial StateTest CurrentLimited TimeProspective ResultStarting State
aIn=63Cold State1.05Int ≤1hNon-tripping
In>63Cold State1.05Int≤2hNon-tripping
bIn=63Hot State1.3Int<1hTrippingThe current rise steadily to a fixed value within 5s
In>63Hot State1.3Int<2hTripping
cIn≥63Cold State8Int≤0.2sNon-Tripping
12Int<0.2sTripping

Characteristics Curve


Current correction values used at different ambient temperatures


Current correction factor used at different altitudes

Rated Current (A)Different altitude correction factors
≤2000m2000m~3000m>3000m
63,80,100,125A1.00.90.8


Accessories

Application

ItemCodeApplicationStandard
Auxiliary ContactsOFOffer auxiliary signal control auxiliary circuit

IEC60947-5-1

GB14048.5

Alarm ContactsSDProvide an alarm signal when the MCB trip off

IEC60947-2

GB14048.2

Shunt TripperHDMXIt will let the MCB trip off when the operating voltage exceed the rated voltage by 70%~110%

IEC60947-1

GB14048.1

Shunt Tripper + Auxiliary ContactMX+OFRemote break the circuit and let the auxiliary contacts control the circuit

IEC60947-1

GB14048.1

Over/under Voltage ReleaseMV+MNIt can peotect the MCB from under / over voltage

IEC60947-2

GB14048.2


Technical Data



Working Condition


Temperature: -5℃~+40℃

Altitude : under 2000m

Installation : 35mm DIN rail


Dimensions


China Standard IEC60947-2 10KA 415V 2P AC Circuit Breaker supplier

Standard IEC60947-2 10KA 415V 2P AC Circuit Breaker