2 Pole High Voltage Contactor Relay 24VDC IP67 High Load Current

Brand Name:FEEO
Certification:CB CE ROHS
Model Number:Dc Contactor
Place of Origin:China
Model Number::FDCT-250A
Electricity Type::DC
Contact Now

Add to Cart

Active Member
Address: Keaisi Road, Xiangyang Industrial zone , Yueqing, Zhejiang,China.
Supplier`s last login times: within 48 hours
Product Details Company Profile
Product Details

ParametersStandard Type Voltage
12VDC24VDC
Work voltage9~1618~32
Max voltage1632
Action voltage≤9≤18
Release voltage≥1≥2
Coil Resistance2594
Min start current0.48A0.26A
Transient surge current--
Average holding current0.48A0.26A
steady state time5.8W6W
Actuation time≤50ms≤50ms
Release time≤10ms≤10ms
Bounce time≤5≤5

Parameters

Contact form1HLeading-outM8 internal thread
Contact resistance0.2 mΩ(200A)Rated load voltage12~900VDC
Maxmum switching current2000A 320VDC ( over 1 times)Maximum Switching power640KW
Rated load current200ARated Electric life10000 (times)
Min load1A12VDCStandards for electric current (10mm2 line0200A
short time overload current320A 5min, 400A 2min 500A 30s

Conditions of usage

Operate temperature-40℃~85℃
Operating Humidity5%~95%RH
IP GradeIP67
Dimension (W*H*D)80*64.2*74
Weight (g)Q: 460g

The action principle of the DC contactor is similar to that of the AC contactor, but the magnetic field energy stored by the inductive load is released instantaneously when the DC is disconnected, and a high-energy arc is generated at the breaking point. Therefore, the DC contactor is required to have a certain arc extinguishing function. Medium/large-capacity DC contactors often adopt a single-break point planar layout overall structure, which is characterized by a long arc distance during breaking, and the arc extinguishing cover contains an arc extinguishing grid. The small-capacity DC contactor adopts a three-dimensional arrangement structure with double break points.

Pay attention to the following points when choosing a contactor.

1. The rated voltage of the main contact ≥ the rated voltage of the load.

2. The rated current of the main contact is ≥1.3 times the rated current of the load.

3. The rated voltage of the coil. When the circuit is simple and uses less electrical appliances, you can choose 220V or 380V; when the circuit is complex, use more electrical appliances or where it is not safe, you can choose 36V, 110V or 127V.

4. The number and type of contacts of the contactor should meet the requirements of the control circuit.

5. Operating frequency (number of contacts on and off per hour). When the on-off current is large and the on-off frequency exceeds the specified value, the contactor model with the rated current one level higher should be selected. Otherwise, the contacts will be severely heated, or even welded together, causing the motor and other loads to run without phase.inverter reference on