3200W 60A Rectifier Used In Telecommunication

Brand Name:ESTEL
Certification:ISO
Model Number:GPE4860G
Minimum Order Quantity:1 Set
Delivery Time:20 days
Payment Terms:L/C, T/T
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen Guangdong China
Address: 3A-8, No. 111, Taizi Road, Shuiwan Community, Zhaoshang Street, Nanshan District, Shenzhen, Guangdong, China
Supplier`s last login times: within 24 hours
Product Details Company Profile
Product Details

3200W 60A Telecom Power Supply Rectifier Input 220VAC Output 48VDC

Two 30A Rectifier Module One Monitoring Module


Model: GPE4860G


I. System configuration


The system consists of distribution unit, rectifier module (up to 2 sets) and 1 monitoring module. The configuration is optional, as following table:


ConfigurationRectifier ModuleMonitoring ModuleDistributionRemark
StandardGPR4830B1 / GPR4830AGPM48M / GPM48F

DC output:

40A×1 (Load);

Battery output: 40A×1 (Battery)

For details, please refer to the specifications of rectifier and monitoring modules.

II. Operating principle


Under normal conditions, every parameter of rectifier modules and distribution unit are all under control of the monitoring module, operating according to the pre-set parameter or user’s commands. If AC mains fault, the system will be powered by the battery. With the battery discharge, the terminal voltage of the battery starts to descend. When the battery voltage is under 42V±0.5V, the monitoring module reports battery under voltage alarm signal and cuts off the load output, then the power system stops working. When the external AC mains recovers, the system will resume to the normal work state. (All above monitoring data are system default values that users can reset).


Except for battery over-discharge protection, battery or load over-temperature protection is prohibitive under default, users can send command to activate or inactivate according to the demanding. When the operating temperature is 55°C or more, power de-rating will be employed by system (at 65°C,system output power is 2600W).


III. Application


■ Small scale program controlled exchanger

■ Access network

■ Transmission equipment

■ Mobile communication

■ Satellite communication ground station

■ Microwave communication


IV. System Specifications


Input
ParameterMin.TypicalMax.UnitRemark
Input voltage range90220280VacNominal operating voltage: 100V-240V
Input frequency455065Hz
Inrush current50ACold start @ 25°C, 280 Vac input,Tested at full load
Power factor0.99

Output
ParameterMin.TypicalMax.UnitRemark
Output voltage rating-53.5Vdc
Output voltage range-43.2-53.5-57.6Vdc
Output current range060A176~280VAC
Ripple (Vp-p)200mvAfter 1-hour operation at low temperature, apply 0.1uF film capacitor and 10uF HF electrolyte capacitor, oscilloscope band width of 20MHz, with 20CM twisted pair.
Output efficiency90%220Vac input, rated output
83%110Vac input, 15A output
Regulation±2%
Load regulation±2%
Line regulation±1%
Output power3200W176-280V Input
1600W90-175V Input

Mechanical specifications
Dimensions (Overall)442mm×250mm×43.5mm
Weight(kg) (Overall)≤7Kg(including modules)

V. Electric connection


Chassis connects with external electric through system interface board. As shown in figure below:



VI. Functions of monitoring module


ItemRemark
Remote monitoring of the hostThe host can conduct enquiries, settings and control upon the monitoring and realize the remote message, remote sense and remote control.
Rectifier management by monitoring moduleTo send controlling orders or to get data from the rectifier module via RS485 communication.
Battery managementTo manage low voltage, power down, equalizing/float charge, temperature compensation of the battery.
Output management by monitoring moduleTo inspect and control the system
LED indicatorSignal indication
2 dry contacts outputAC fail alarm; battery under-voltage alarm output
COM port signalSensor input and dry contact output
For details, please refer to specifications of “GPM48M / GPM48F”.

VII. Rectifier Module Specifications


ItemUnitMin.TypicalMax.Remarks
AC input voltageVac90220280
AC input voltage frequencyHz455065Rated load
Input power factor0.99Rated voltage/ rated load
Output voltage rangeVdc425458
Output currentA030176~280V ac Input
Output voltage regulation±1%
Ripple (Vp-p)mV200With 0.1uF filmy capacitor and 10uF high frequency electrolyte capacitor, oscilloscope band width of 20MHz.
Output powerW01600176-280V Input
W080090-175V Input
Output efficiency%91220V AC Input
%83110V AC Input
Input over-voltage protectionVdc285305Tested with 15A, auto recoverable
Input over-voltage recovery set pointVdc280Hysteresis not less than 5V.
Input under-voltage protectionVdc85Tested with 4A, auto recoverable
Input under-voltage recovery set pointVdc90Hysteresis not less than 5V.
Output over-voltage protection set pointV58.55961.5Lock up
Output current limitingA313335Auto recoverable
Short circuit protectionALong-term short circuit endurable; Hiccup when short circuit detected; Auto recoverable
Thermal protectionAuto recoverable under ambient temperature of 65°C, temperature drop curve is see below Note 1.
Fan failure protectionWhen the single fan fault, module is automatically reduced to half power operation and report alarm, until over temperature protection of the module close output; when two fans are failure, the module reported the fan failure alarm, then directly close the output.
For details, please refer to specifications of GPR4830A1.

VIII. Rectifier System Installed Inside Outdoor Power Supply Cabinet For Telecom





China 3200W 60A Rectifier Used In Telecommunication supplier

3200W 60A Rectifier Used In Telecommunication

Inquiry Cart 0