Dräger X-am® 8000Multi-Gas Detector
Clearance measurement was never this easy and convenient:The 1 to 7 gas detector detects toxic and flammable gases as well as vapours and oxygen all at once - either in pump or diffusion mode.Innovative signalling design and handy assistant functions ensure complete safety throughout the process.


1.Technical Data

Dimensions (H x W x D)179 x77 x 42 mm
Weight

Approx. 495 g, depending on sensor configuration, without strap, without pump

Approx. 550 g, depending on sensor configuration, without strap, with pump

HousingDurable two-component housing
DisplayHigh-contrast colour display
Temperature-20 ℃ to 50 ℃
Pressure

700 to 1,300 hPa (measuring function)

800 to 1,100 hPa (use in explosion-hazard areas)

Relative humidity10 to 90 % (short-term up to 95 %)r.h.
AlarmsVisual:

3 LED 'red'(gas alarms),

3 LED 'yellow'(device alarms)

AcousticMulti-tone, typically 100 dB(A) at 30 cm
Vibration
Ingress protection classIP 68
Energy supplyLithium-ion battery, rechargeable, inductive charging
Operating times (Diffusion)With CatEx and 3 EC sensorsTypically 24 hours
With lR and 3 EC sensorsTypically 22 hours
With 3 EC sensorsTypically 120 hours
With CatEx, PlD and 3 EC sensorsTypically 17 hours
With lR, PlD and 3 EC sensorsTypically 16 hours
With CatEx-, IR- and 3 EC sensorsTypically 14 hours
PID onlyTypically 42 hours
Charging timesTypically 4 hours after use during a shift of max. 10 hours
Start-up timesTypically <60 seconds for standard sensors
Data storage24 MB, e.g. at 10 minutes per hour of gas exposure with measuring values changing bythe second on all 7 channels: approx. 400 hours
Pump operationMax. hose length 45 m
ApprovalsMarking Explosion Protection:
ATEX /IECEXI M1, II 1G
Ex da ia l Ma, Ex da ia llC T4 Ga
EACPO Ex da ia l Ma X
OEx da ia llC T4 Ga X
cCSAusClass l, Zone 0, AEx da ia llC T4 Ga
Class ll, Div 1, Gr. E,F,G
C22.2 No.152,ANSISA 12.13.01:2000
ANZExEx da ia l Ma, Ex da ia llC T4 Ga
Measurement Performance:

Explosion protection according ATEX:

EN 60079-29-1(CatEx 125 PR, CatEx125 PR Gas, (Dual) IR Ex, XXS H2 HC)

CatEx 125 PR and (Dual) IR Ex: methane,propane, n-nonane, etc.

The following applies to the CatEx 125 PR and approved gas "n-nonane": Only in conjunction with pump adapter "Nonan"part number: 3720225

Oxygen deficieny/excess oxygen:

EN 50104 (XXS O,/ XXS O,PR)

Toxic gases:

EN 45544-1, EN 45544-2,EN 45544-3(XXS H,S LC, XXS CO LC, (Dual) IR COz)

Software: EN 50271
Directives2014/34/EU(ATEX)
2014/30/EU(EMV)
2011/65/EU(RoHS)
2014/90/EU (MED)
Marine ApprovalDNV GL
Manufacturer´s warranty3 years for the device
1 year for the power supply
Sensors: see DrägerSensor"& Portable Instruments Handbook