Medical Home O2 Meter Finger LED Screen Clear Reading Accuracy 2bpm

Certification:CE,ISO13485,FDA
Model Number:ZLK-PO1
Minimum Order Quantity:100PCs
Delivery Time:5-8 work days
Payment Terms:L/C, D/A, T/T,
Place of Origin:China
Contact Now

Add to Cart

Active Member
Location: Xiangtan Hunan China
Address: 2nd Floor, Building 10, Innovation and Entrepreneurship Center, No.9 Chuanqi West Road, Jiuhua Economic Development Zone, Xiangtan City, Hunan Province, China
Supplier`s last login times: within 30 hours
Product Details Company Profile
Product Details

Product Name


Portable Medical Home LED Screen Clear Reading Fingertip Pulse Oximeter


Feature


ACCURATE, FAST AND RELIABLE - the CMS 50 DL Fingertip Pulse Oximeter accurately determines your SpO2 in less than 8 seconds

SPORT/HEALTH ENTHUSIASTS - For aviators, sporting enthusiasts, skiers, bikers, or high altitude climbing, the CMS 50 DL is a RELIABLE companion for quick and easy readings for oxygen saturation

THE ORIGINAL STANDARD - Setting the original standard for reliable and consistent pulse oximetry, the CMS 50 DL is backed by an ironclad 12-month warranty

PACKED WITH ACCESSORIES - Includes 2X AAA batteries that enable use out of the box, a pulse oximeter case to protect the device when not in use, and a LANYARD for convenience as either a wrist strap or to be worn around the neck

DESIGNED For Sports and Aviation Enthusiasts and can be used as a heart rate monitor


How to ensure the accuracy of your measurement?

1, Moving too fast will affect the accuracy; try to stay still while waiting for your reading.

2, When the oxygen saturator and the heart are at the same level, the measurement results are optimal.

3, Avoid nail polish or long nails on the finger used for the reading. Fingers should not be wet at all either.

4, Ring finger, middle finger and index finger are recommended as suitable monitor position


Function Specification

Display InformationDisplay Mode
The Pulse Oxygen Saturation(SpO2)LED
Pulse Rate(PR)LED
Pulse Intensity (bar -graph)LED
Pulse waveLED
SpO2 Parameter Specification
Measuring range0%~-100%, (the resolution is 1%).
Accuracy70%~100%±2%, Below 70% unspecified.
Optical Sensor

Red light (wavelength is 660nm)

Infrared (wavelength is 880nm)

Pulse Parameter Specification
Measuring range30bpm~250bpm (the resolution is 1 bpm)
Accuracy±2bpm or±2% select larger
Pulse Intensity
RangeContinuous bar-graph display, the higher display indicate the strong pulse
Battery Requirement
1.5V (AAA size) alkaline batteries x 2 or rechargeable battery
Battery Useful Life
Two batteries can work continally for 20 hours
Dimensions and Weight
Dimensions57(L) x 31(W) x 32(H) mm .
WeightAbout 50g (with the batteries)


Environment Requirements

Storage Environment

a) Temperature :-40℃~+60℃

b) Relative humidity :<95%

c) Atmospheric pressure :500hPa~1060hPa

Operating Environment

a) Temperature :10℃~40℃

b) Relative Humidity :s75%

c) Atmospheric pressure :700hPa~1060hPa


1) Display Format: OLED Display;

SpO2 Measuring Range: 0%- 100%;


Pulse Rate Measuring Range: 30 bpm - 250 bpm;


Pulse Wave Display: columniation display and the waveform display.


2) Power Requirements: 2 x1.5V AAA alkaline battery(or using the

rechargeable battery instead), adaptable range: 2.6V~3.6V.


3) Power Consumption: Smaller than 30mA.


4) Resolution: 1% for SpO2 and 1 bpm for Pulse Rate.


5) Measurement Accuracy: ±2% in stage of 70%-100% SpO2 , and

meaningless when stage being smaller than 70%.±2 bpm or±2%

(select larger) for Pulse Rate.


6) Measurement Performance in Weak Filling Condition:

SpO2 and pulse rate can be shown correctly when pulse-filling ratio

is 0.4%. SpO2 error is ±4%, pulse rate error is +2 bpm or±2% (select larger).


7) Resistance to surrounding light: The deviation between the value

measured in the condition of man-made light or indoor natural light and that

of darkroom is less than ±1%.


8) It is equipped with a function switch. The Oximeter can be powered off in

case no finger is the Oximeter within 5 seconds.


9) Optical Sensor

Red light (wavelength is 660nm, 6.65mW)

Infrared (wavelength is 880nm, 6.75mW)


Troubleshooting

TroublePossible ReasonSolution

The SpO2 and Pulse Rate can not be displayed normally


1. The finger is not properly positioned.

2. The patient's SpO2 is too low to be detected.


1. Place the finger properly and try again.

2. Try again; Go to a hospital for a diagnosis if you are sure the device works all right.

The SpO2 and Pulse

Rate are not

displayed stably


1. The finger is not placed inside deep enough.

2. The finger is shaking or the patient is moving.

1. Place the finger properly and try again.

2. Let the patient keep calm


The device can not

be turned on


1. The batteries are drained or almost drained.

2. The batteries are not inserted properly.

3. The malfunction of the device.

1. Change batteries.

2. Reinstall batteries.

3. Please contact the local service center.


The display is off

suddenly


1. The device will power off

automatically when it gets no signal within 5 seconds.

2. The batteries are almost drained.

1. Normal.

2. Change batteries.





China Medical Home O2 Meter Finger LED Screen Clear Reading Accuracy 2bpm supplier

Medical Home O2 Meter Finger LED Screen Clear Reading Accuracy 2bpm

Inquiry Cart 0