Medical Home Easy Use Digital Accurate SPO2 Blood Oxygen Saturation
Pulse Oximeter Fingertip
Function Specification
Display Information | Display Mode |
The Pulse Oxygen Saturation(SpO2) | LED |
Pulse Rate(PR) | LED |
Pulse Intensity (bar -graph) | LED |
Pulse wave | LED |
SpO2 Parameter Specification | |
Measuring range | 0%~-100%, (the resolution is 1%). |
Accuracy | 70%~100%±2%, Below 70% unspecified. |
Optical Sensor | Red light (wavelength is 660nm) Infrared (wavelength is 880nm) |
Pulse Parameter Specification | |
Measuring range | 30bpm~250bpm (the resolution is 1 bpm) |
Accuracy | ±2bpm or±2% select larger |
Pulse Intensity | |
Range | Continuous bar-graph display, the higher display indicate the strong pulse |
Battery Requirement | |
1.5V (AAA size) alkaline batteries or 2 rechargeable battery | |
Battery Useful Life | |
Two batteries can work continally for 20 hours | |
Dimensions and Weight | |
Dimensions | 57(L) x 31(W) x 32(H) mm . |
Weight | About 50g (with the batteries) |
Environment Requirements
Storage Environment
a) Temperature :-40℃~+60℃
b) Relative humidity :<95%
c) Atmospheric pressure :500hPa~1060hPa
Operating Environment
a) Temperature :10℃~40℃
b) Relative Humidity :s75%
c) Atmospheric pressure :700hPa~1060hPa
1) Display Format: OLED Display;
SpO2 Measuring Range: 0%- 100%;
Pulse Rate Measuring Range: 30 bpm - 250 bpm;
Pulse Wave Display: columniation display and the waveform display.
2) Power Requirements: 2 x1.5V AAA alkaline battery(or using the rechargeable
battery instead), adaptable range: 2.6V~3.6V.
3) Power Consumption: Smaller than 30mA.
4) Resolution: 1% for SpO2 and 1 bpm for Pulse Rate.
5) Measurement Accuracy: ±2% in stage of 70%-100% SpO2 , and meaningless
when stage being smaller than 70%.±2 bpm or±2% (select larger) for Pulse Rate.
6) Measurement Performance in Weak Filling Condition: SpO2 and pulse rate
can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate
error is +2 bpm or±2% (select larger).
7) Resistance to surrounding light: The deviation between the value measured in
the condition of man-made light or indoor natural light and that of darkroom is less than ±1%.
8) It is equipped with a function switch. The Oximeter can be powered off in case no
finger is the Oximeter within 5 seconds.
9) Optical Sensor
Red light (wavelength is 660nm, 6.65mW)
Infrared (wavelength is 880nm, 6.75mW)
Troubleshooting
Trouble | Possible Reason | Solution |
The SpO2 and Pulse Rate can not be displayed normally | 1. The finger is not properly positioned. 2. The patient's SpO2 is too low to be detected. | 1. Place the finger properly and try again. 2. Try again; Go to a hospital for a diagnosis if you are sure the device works all right. |
The SpO2 and Pulse Rate are not displayed stably | 1. The finger is not placed inside deep enough. 2. The finger is shaking or the patient is moving. | 1. Place the finger properly and try again. 2. Let the patient keep calm |
The device can not be turned on | 1. The batteries are drained or almost drained. 2. The batteries are not inserted properly. 3. The malfunction of the device. | 1. Change batteries. 2. Reinstall batteries. 3. Please contact the local service center. |
The display is off suddenly | 1. The device will power off automatically when it gets no signal within 5 seconds. 2. The batteries are almost drained. | 1. Normal. 2. Change batteries. |
Who need this?
People with vascular disease (coronary heart disease, high blood pressure,
high blood lipids, cerebral thrombosis...)
There are lipid deposits in the vascular cavity, and the blood is not smooth.
In patients with cardiovascular and cerebrovascular problems with oxygen supply,
the blood is thick, coupled with coronary artery hardening, and the vascular cavity
is narrowed, so that the blood supply is not smooth and the oxygen supply is difficult.
The body is "hypoxia" every day. Long-term mild hypoxia, the heart, brain and other
organs that consume a lot of oxygen will gradually decline. Severe hypoxia can cause
"myocardial infarction" and "cerebral infarction". If oxygen is not supplied in time, it will
cause sudden death. Therefore, the long-term use of pulse oximetry to detect the blood
oxygen content of cardiovascular and cerebrovascular patients can effectively prevent
the occurrence of danger. If hypoxia occurs, oxygen can be supplemented as soon as
possible, which greatly reduces the chance of disease.
People with respiratory diseases (asthma, bronchitis, old chronic bronchitis,
pulmonary heart disease, chronic obstructive pulmonary disease...)
Difficulty in breathing leads to limited intake of oxygen. Blood oxygen testing for respiratory
patients is indeed very important. On the one hand, breathing difficulties can lead to insufficient
oxygen uptake. On the other hand, the persistence of asthma will also block the small organs
and cause gas exchange. Difficulty occurs, leading to hypoxia, causing heart, lung, brain and
even kidney damage to varying degrees. Therefore, the use of pulse oximeter to detect blood
oxygen content greatly reduces the incidence of respiratory tract.
People over 60 years old
Physiological aging of the heart and lung organs, insufficient oxygen uptake. Inadequate oxygen
supply.The human body relies on blood to transmit oxygen. If there is less blood, there will
naturally be less oxygen. With less oxygen, the physical condition will naturally decline. Therefore,
the elderly should use pulse oximetry to test the blood oxygen level every day. Once the blood
oxygen is below the warning level, oxygen should be supplemented as soon as possible.
People who work more than 12 hours a day
The brain's oxygen consumption increases, and the oxygen supply cannot meet the consumption
The oxygen consumption of the brain accounts for 20% of the whole body oxygen uptake, and
the brain's oxygen consumption will inevitably increase with the transition of mental work.
The human body can take in limited oxygen, consumes more, and consumes less. In addition
to causing dizziness, fatigue, poor memory, slow reflection and other problems, it can also
cause serious damage to the brain and myocardium, and even death from overwork. Therefore,
people who study or work 12 hours a day must use pulse oximetry to test blood oxygen every
day Content, monitor blood oxygen health from time to time, to ensure heart and brain health.
Athlete/Health enthusiasts/High altitude climbing
For aviators, sporting enthusiasts, skiers, bikers, or high altitude climbing, it is a RELIABLE
companion for quick and easy readings for oxygen saturation.Real-time blood oxygen monitoring
of athletes helps to understand the blood circulation of athletes after a large amount of exercise,
so as to guide the formulation of athletes' exercise volume.
Long-term alcoholics
The human body needs three units of oxygen for every unit of alcohol that is completely decomposed
into water and carbon dioxide. Therefore, hypoxia is one of the important manifestations of drunkenness. However, long-term alcoholics have formed a certain tolerance to alcohol and hypoxia, and they are
basically unable to detect them when they are slightly drunk. Therefore, carry an oximeter with you
to know the physical condition and drunkenness of alcoholics in time to avoid alcoholism.
How to ensure the accuracy of your measurement?
1,Moving too fast will affect the accuracy; try to stay still while waiting for your reading.
2,When the oxygen saturator and the heart are at the same level, the measurement results are optimal.
3, Avoid nail polish or long nails on the finger used for the reading. Fingers should not be wet at all either.
4,Ring finger, middle finger and index finger are recommended as suitable monitor position