30 Bpm - 250 Bpm FDA Blue Oxygen Finger Pulse Oximeter With Lanyard

Model Number:ZLK-PO1
Minimum Order Quantity:100PCs
Delivery Time:5-8 work days
Payment Terms:L/C, D/A, T/T,
Place of Origin:China
Price:USD 3-4/Pcs
Contact Now

Add to Cart

Active Member
Location: Xiangtan Hunan China
Address: 2nd Floor, Building 10, Innovation and Entrepreneurship Center, No.9 Chuanqi West Road, Jiuhua Economic Development Zone, Xiangtan City, Hunan Province, China
Supplier`s last login times: within 30 hours
Product Details Company Profile
Product Details

Product Name

Navy Blue Fingertip Pulse Oximeter Blood Oxygen Saturation Monitor with Lanyard


Feature

[Accurate & Reliable Detection]: Adopted advanced chipset and infrared detector,

the pulse oximeter can ensure that you will get accurate and reliable reading.

Fingertip pulse oximeter accurately determines your SpO2 and pulse rate and

shows conveniently on a large digital LED display.


[Easy to Use]: Just put your finger in, and press the button, the readings will show

on the display within 8s. One button control makes measurement more convenient

and easier, even the kids and the seniors can operate it alone. Our SpO2 sensor

supports spot check and displays in real time your pulse rate, oxygen saturation

and pulse bar graph which shows the intensity of the signal strength.


[User Friendly Design & Portable]: The pulse oximeter adopts medical-grade silicone

finger mold, providing you with a comfortable measurement. Compact design allows

you to put it into the pocket or hang it on your neck with a lanyard and carry it anywhere

and measure your heart rate and blood oxygen anytime.


[Auto Shut-off & Long Battery Life]: The pulse rate monitor will automatically shut off

when it does not detect your fingers within 5 seconds, which ensures low power consumption.

2*AAA batteries included support 600 times measurement and more than 30 hours of continuous

working time.


[Wide Application]: Liorque pulse oximeter is suitable for home use and outdoor use and

accommodates wide range of finger sizes - children to adult. You should only use the pulse

oximeter before or after your exercise. You must remain stationary while the pulse oximeter

measure your pulse rate and SpO2 levels.


Function Specification

Display InformationDisplay Mode
The Pulse Oxygen Saturation(SpO2)LED
Pulse Rate(PR)LED
Pulse Intensity (bar -graph)LED
Pulse waveLED
SpO2 Parameter Specification
Measuring range0%~-100%, (the resolution is 1%).
Accuracy70%~100%±2%, Below 70% unspecified.
Optical Sensor

Red light (wavelength is 660nm)

Infrared (wavelength is 880nm)

Pulse Parameter Specification
Measuring range30bpm~250bpm (the resolution is 1 bpm)
Accuracy±2bpm or±2% select larger
Pulse Intensity
RangeContinuous bar-graph display, the higher display indicate the strong pulse
Battery Requirement
1.5V (AAA size) alkaline batteries x 2 or rechargeable battery
Battery Useful Life
Two batteries can work continally for 20 hours
Dimensions and Weight
Dimensions57(L) x 31(W) x 32(H) mm .
WeightAbout 50g (with the batteries)

Environment Requirements

Storage Environment

a) Temperature :-40℃~+60℃

b) Relative humidity :<95%

c) Atmospheric pressure :500hPa~1060hPa

Operating Environment

a) Temperature :10℃~40℃

b) Relative Humidity :s75%

c) Atmospheric pressure :700hPa~1060hPa


1) Display Format: OLED Display;

SpO2 Measuring Range: 0%- 100%;

Pulse Rate Measuring Range: 30 bpm - 250 bpm;

Pulse Wave Display: columniation display and the waveform display.


2) Power Requirements: 2 x1.5V AAA alkaline battery(or using the

rechargeable battery instead), adaptable range: 2.6V~3.6V.

3) Power Consumption: Smaller than 30mA.

4) Resolution: 1% for SpO2 and 1 bpm for Pulse Rate.

5) Measurement Accuracy: ±2% in stage of 70%-100% SpO2 , and

meaningless when stage being smaller than 70%.±2 bpm or±2%

(select larger) for Pulse Rate.

6) Measurement Performance in Weak Filling Condition: SpO2 and

pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2

error is ±4%, pulse rate error is +2 bpm or±2% (select larger).

7) Resistance to surrounding light: The deviation between the value

measured in the condition of man-made light or indoor natural light and

that of darkroom is less than ±1%.

8) It is equipped with a function switch. The Oximeter can be powered

off in case no finger is the Oximeter within 5 seconds.

9) Optical Sensor

Red light (wavelength is 660nm, 6.65mW)

Infrared (wavelength is 880nm, 6.75mW)