Fiber Optic Fusion Splicer Splicing Machine Replacement Electrode
Description:
Optical Electrode length tolerances strictly controlled within 0.02mm, to ensure the stability of discharge.
In China accounted for 80% market share. Monthly output of 10000 pairs, each pair of electrodes have been detected 450 times magnifying glass.
Feature:
1. Discharge life:> 5000(please note you need clean and maintain the elctrodes per 1000 secondary discharge)
2.Splice loss: <0.02db
The best electrodes, top quality, high performance, low cost, the pursuit of quality and cheap.
Specification:
Product name | fiber optic fusion splicer electrode |
Application: | Customers request |
Life: | 5000times |
Unit | 1pair |
Material: | Imported Tungsten Steel |
Weight | 6g |
Advantage: | long-last lifespan |
Color: | black silver |
How to replace the electrode?
First, make sure that the fusion splicer is off, remove the
protective cover of the electrode chamber, loosen the screws that
fix the upper electrode, take out the electrode, and then loosen
the top wire of the lower electrode to take out the electrode.
Secondly, install a new electrode, the operation steps are opposite
to the method of disassembling the electrode, just operate in
sequence. The gap between the two electrode tips is required to be;
2.6 plus or minus 0.2 mm. Finally, during the assembly process, do
not touch the electrode tip to prevent damage to the electrode and
prevent the electrode from falling into the machine and causing
damage. After replacing the electrode, the arc position should be
calibrated.
Electrode cleaning and arc calibration
1. After the electrode is installed, turn on the power switch of
the fusion splicer.
2. After the splicer enters the initial screen, press the menu
button to enter the first level menu.
3. Find the machine maintenance by moving the cursor, enter the
cleaning electrode item, after confirmation, the machine will
automatically discharge to clean and age the electrode.
4. Install the cut left and right fibers, find the arc position
item by moving the cursor, and keep the fiber end face and the two
electrode tips at three points and one line through the operation,
the machine will conduct a discharge test, and adjust it according
to the actual situation.
5. Finally, press the menu button to exit in turn.