Fiber Optic Sumitomo Electrodes Type-35 Type-36 Type-39 Fiber Optic Fusion Splicer Electrodes
Description:
Imported high-quality tungsten steel, stable discharge, low loss,
long life, precision machining
Complete models, quality assurance, stable discharge, connect at
least 40,000 cores
The imported tungsten steel electrode is magnified 400 times under the microscope, the tip of the electrode is still sharp, the surface is clean and smooth, which ensures the stability of discharge, low loss and long service life.
Under the microscope of ordinary material electrode, the electrode tip becomes blunt after 400 times magnification, the surface is rough, causing discharge deviation, large loss and easy damage to the welding machine.
Feature:
1. Imported tungsten steel material uses 93A fine grain tungsten steel
2. Stable discharge, low loss, can be used for trunk welding
3. Excellent quality, precise craftsmanship, precise processing
size
4.Durable fixing cap The fixing cap is made of insulating material,
resistant to high temperature and no deformation
5. Protective sleeve protection The outside of the rod body is
protected by a protective sleeve to avoid abrasion when it is not
used.
Imported tungsten steel electrode or common material electrode
or
Specification:
Product name | fiber optic fusion splicer electrode |
Application: | Customers request |
Life: | 4000times |
Unit | 1pair |
Material: | Imported Tungsten Steel |
Weight | 6g |
Advantage: | long-last lifespan |
Color: | black silver |
How to replace the electrode?
First, make sure that the fusion splicer is off, remove the
protective cover of the electrode chamber, loosen the screws that
fix the upper electrode, take out the electrode, and then loosen
the top wire of the lower electrode to take out the electrode.
Secondly, install a new electrode, the operation steps are opposite
to the method of disassembling the electrode, just operate in
sequence. The gap between the two electrode tips is required to be;
2.6 plus or minus 0.2 mm. Finally, during the assembly process, do
not touch the electrode tip to prevent damage to the electrode and
prevent the electrode from falling into the machine and causing
damage. After replacing the electrode, the arc position should be
calibrated.
Electrode cleaning and arc calibration
1. After the electrode is installed, turn on the power switch of
the fusion splicer.
2. After the splicer enters the initial screen, press the menu
button to enter the first level menu.
3. Find the machine maintenance by moving the cursor, enter the
cleaning electrode item, after confirmation, the machine will
automatically discharge to clean and age the electrode.
4. Install the cut left and right fibers, find the arc position
item by moving the cursor, and keep the fiber end face and the two
electrode tips at three points and one line through the operation,
the machine will conduct a discharge test, and adjust it according
to the actual situation.
5. Finally, press the menu button to exit in turn.