CTI 0-600V Tracking Index Horizontal Flammability Tester

Brand Name:HeJin
Certification:calibration certificate(cost additional)
Model Number:LT-3
Minimum Order Quantity:1 set
Delivery Time:30 days
Payment Terms:L/C, T/T
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou Guangdong China
Address: No.6-36, Yaogu Farm, Shibi No.3 Village, Shibi Street, Panyu District, Guangzhou, Guangdong, China
Supplier`s last login times: within 23 hours
Product Details Company Profile
Product Details

Flammability Testing Equipment Tracking Index Apparatus CTI 0-600V Voltage


Standard:

The tracking index apparatus is designed and manufactured to perform the test specified in the norm IEC 60112 ("method for determining the comparative and the proof tracking index of solid insulating materials under moist conditions") and many others standards ( IEC 60335, IEC 60065, IEC 60745, IEC 61029 ) to determine compliance with safety requirements related to solid insulating materials under moist conditions.


Feature:

Tracking index tester which is also called as tracking tester is for the determination of the proof and comparative tracking indices of solid insulating materials on pieces taken from parts of equipment and on plaques of material using alternating voltages. By providing comparative tracking index (CTI), proof tracking index (PTI), electrical erosion (as required), the tester can help people to evaluation the safety of electrical apparatus.


Application:

The product is typically used to asses the tracking characteristics of an insulator due to liquid impurities that create conducting paths along the insulator surface. Flammability Testing Equipment


Parameter:

Timing device9999X0.1S ResolutionDrip intervalAdjustable
Electrode materialPlatinumThe height of the drip30-40mm
Electrode specifications5mm*2mmDrip delay0.2S (solenoid valve open time)
Electrode spacing4±0.1mmDrip size45 - 50 drops / cm3
Electrode pressure1±0.05 NDelay electric circuit2 ± 0.1S (at 0.5A)
Electrode angle60°Test voltage range

0-600V

Accuracy:1.5%

Short circuit voltage drop8% MAXElectrical parameters1.5KW/220VAC/50Hz
Short-circuit current1±0.1A Accuracy: 1%Working volume> 0.5 M³. Flammability Testing Equipment

China CTI 0-600V Tracking Index Horizontal Flammability Tester supplier

CTI 0-600V Tracking Index Horizontal Flammability Tester

Inquiry Cart 0