IEC60811-1-4 100mm Height Low Temperature Impact Test Apparatus

Brand Name:HeJin
Certification:calibration certificate (cost additional)
Model Number:HC9924
Minimum Order Quantity:1 set
Delivery Time:15 days
Payment Terms:L/C, T/T
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou Guangdong China
Address: No.6-36, Yaogu Farm, Shibi No.3 Village, Shibi Street, Panyu District, Guangzhou, Guangdong, China
Supplier`s last login times: within 23 hours
Product Details Company Profile
Product Details

Plug Socket Test Equipment Low Temperature Impact Test Apparatus


Standard:

IEC 60884-1 2013 ‘Plugs and socket-outlets for household and similar purposes -- Part 1: General requirements’ clause 24.4, 30.4

IEC60811-1-4 ‘Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section Four: Tests at low temperature’


Application:

This device is use for checking the impact resistance at low temperature of electrical accessories, as well as wires and cables.Plug Socket Test Equipment


Test sample:

Electrical accessories, surface type mounting boxes, screw glands, covers, wires and cables etc.Plug Socket Test Equipment


Feature:

This device should be used with low temperature chamber, the device should be placed on the sponge rubber pad of about 40mm thick, and should be put in the low temperature chamber before and during the test.


Parameters:

ModelImpact test apparatus HC9924Impact test apparatus HC9924A
StationSingle stationThree stations
Weight of the impact hammer (g)1000±2 and 100±1100, 200, 300, 400, 500, 600, 750, 1000, 1250, 1500(See table 1 and 2)
Height of the impact (mm)100100
Steel intermediate pieceΦ20, bottom end rounded R300, 100gΦ20, bottom end rounded R300, 100g
Standard

IEC60884-1 24.4 Figure 27

IEC60884-1 30.4 Figure 42

IEC60811-1-4
OperationManual, mechanical releaseManual, mechanical release

Table1 For power cables for fixed installation, the mass of the hammer for testing the samples shall be as given in the following table:

Overall diameter (mm)Mass of hammer (g)
AboveUp to and including
-4.0100
4.06.0200
6.09.0300
9.012.5400
12.520.0500
20.030.0750
30.050.01000
50.075.01250
75.0-1500

Table 2 For flexible cables and cords and telecommunication cables, the mass of the hammer for testing the sample shall be as follows:

Overall diameter (mm)Mass of hammer (g)
AboveUp to and including
For flat cords100
-6.0100
6.010.0200
10.015.0300
15.025.0400
25.035.0500
35.0-600

China IEC60811-1-4 100mm Height Low Temperature Impact Test Apparatus supplier

IEC60811-1-4 100mm Height Low Temperature Impact Test Apparatus

Inquiry Cart 0