Helium Detection System for Automotive Relays Maximum leak detection accuracy ≤5*10-10Pa·m3/s

Helium Detection System for Automotive Relays


Introduction of Helium Detection System for Automotive Relays:

This system can complete the scanning of car relays, helium leak detection, result judgment, data recording and uploading.

The workflow includes installing the workpiece, vacuuming the vacuum chamber, filling the workpiece with helium, detecting fine leakage of the workpiece, filling the vacuum chamber with helium, and manually unloading the workpiece.


Feature of Helium Detection System for Automotive Relays:

1. Background cleaning technology: HJ has a patented helium background noise cleaning technology that can effectively eliminate the helium background noise in the vacuum chamber system. Provide a clean and stable benchmark background indicator environment for the system, avoid exceeding the helium background noise level of the system and affecting the stability of system operation, and improve the operational efficiency of the system.

2. Specially designed sealing fixtures: Different fixtures can be configured for different workpieces. For different types of workpieces, simply replace the fixture quickly and use this system for leak detection.

3. Calibration techniques

a) Automatic calibration of the system: The operator can complete it with one click through the human-machine interface, making regular precision calibration operations simple.

b) Daily inspection of the system: The standard leak simulation for daily inspection is used to simulate the workpiece to be inspected, and online verification of the system accuracy can fully ensure the stability of the system accuracy and the reliability of operation.

4. System quality assurance for products: As the entire process engineering of the product is automatically completed by the equipment, there is no need for operator judgment and execution, which avoids the influence of human factors on the detection results and ensures the consistency, objectivity, stability, and repeatability of the operation.


Parameter of Helium Detection System for Automotive Relays:

ModelHJ100
Number of vacuum chambersThree, each vacuum chamber can simultaneously detect two workpieces
Vacuum degree of gross leakage detection≤1*10-2 pa
Tracer gasHelium gas
Helium pressure0.3MPa~0.5MPa adjustable
Helium recoveryNo recycling
Cycle Time30 seconds per piece
Maximum leak detection accuracy≤5*10-10Pa·m3/s, Efficiency: 2 pieces/3 minutes