GYTS G652D Outdoor Fiber Optic Cable

Brand Name:Dawnergy
Certification:CE/TELCORDIA
Model Number:GYTS-12/24/48/96/144 G652D
Minimum Order Quantity:100KM
Delivery Time:10-14 work days
Payment Terms:T/T, L/C, D/A, D/P
Contact Now

Add to Cart

Verified Supplier
Location: Shanghai Shanghai China
Address: 1st Floor, A5 Building, NO.3655 SixianRd, Songjiang District, Shanghai 201614 China
Supplier`s last login times: within 28 hours
Product Details Company Profile
Product Details

1. Reference


The cable offered are designed, manufactured and tested according to the standards as follows:


IEC 60794-1-1Optical fibre cables-part 1-1: Generic specification-General
IEC 60794-1-2Optical fibre cables-part 1-2: Generic specification-Basic optical cable test procedure
IEC 60794-3Optical fibre cables-part 3: Sectional specification-Outdoor cables

2. Cable Cross-section

3. Cable Identification


2.1 Fiber color code

No.123456
ColorBlueOrangeGreenBrownGrayWhite
No.789101112
ColorRedBlackYellowVioletPinkAqua

2.2 Loose tube (LT) & filler rod (FR) color code

Fiber countElement no.
123456789101112
12LTLTFRFRFR
24LTLTLTLTFR
48LTLTLTLTFR
96LTLTLTLTLTLTLTLT
144LTLTLTLTLTLTLTLTLTLTLTLT

“LT” means “loose tube”;“FR” means “filler rod”


4. Cable Assembly & Dimensions

ItemContentsValue
12244896144
Loose tubeNumber244812
Outer diameter (mm)1.91.92.12.12.1
Thickness(mm)0.3
MaterialPBT
Water blockingTube filling compound
FillerMaterialPP
Number31100

Max. Fiber counts

per tube

G.652D66121212
Central strength memberMaterialSteel wire
Diameter (mm)1.41.41.62.02.0
PE layer diameter (mm)---3.66.2
Water blockingMaterialWater blocking yarn & Water blocking tape
Outer SheathMaterialHDPE
ColorBlack
Thickness (mm)1.7±0.2
Cable diameter(mm) Approx9.8±0.39.8±0.310.4±0.312.4±0.315.0±0.3
Cable weight(kg/km) Approx.80±5%84±5%96±5%143±5%199±5%

5. Performance of Cabled Optical Fiber


The performance of cabled optical fiber (ITU-T Rec. G.652D)


ItemSpecification
Fiber typeSingle mode
Fiber materialDoped silica

Attenuation coefficient

@ 1310 nm

@ 1550 nm


≤ 0.35 dB/km

≤ 0.21 dB/km

Cable cut-off wavelength ≤1260 nm
Zero-dispersion wavelength1300 ~ 1324 nm
Zero-dispersion slope≤ 0.092 ps/(nm2.km)
PMD≤0.2 ps/km1/2
Mode field diameter @ 1310 nm8.7~9.5 um
Core / Clad concentricity error≤ 0.6 um
Cladding diameter125±1 um
Cladding non-circularity≤1.0%
Primary coating diameter250±15 um

6. Performance of Optical Fiber Cable


6.1 Cable bending radius: 10 x cable diameter (static)

20 x cable diameter (dynamic)


6.2 Application temperature range


Operating temperature range: -40oC to +70oC
Storage / Transport temperature range: -40oC to +70oC
Installation temperature range: -40oC to +70oC

6.3 Mechanical & environmental performance test

S/NItemTest MethodAcceptance Condition
1Tensile Strength IEC 794-1-E1

-Load: 1500N

Length of cable under load: 50m

-Load time: ≥1min.

-Loss change≤0.1 dB@1550 nm after test

-Fiber strain≤0.6%

-No fiber break and no sheath damage


2


Crush Test IEC 794-1-E3

- Load:1000N/100 mm

- Load time: ≥1min.

-Loss change≤0.1 dB@1550 nm after test

-No fiber break and no sheath damage


3


Impact test IEC60794-1-21-E4

-Impact hight:1m

-Impact weight:20J

-Points of impact: 3

-Times of per point: 1

-Radius:300mm

-Loss change ≤ 0.1 dB@1550 nm

-No fiber break and no sheath damage


4


Repeated Bending IEC 794-1-E6

  • Bending radius: 20 x cable diameter

-Load:150N

-Flexing rate: 2 sec/cycle

-No. of cycle: 25

-Loss change≤ 0.1 dB @1550 nm

-No fiber break and no sheath damage


5


Torsion

IEC 794-1-E7

-Length: 1m

-Load:150N

-Twist angle: ±90°

-No. of cycle: 10

-Loss change≤0.1 dB @1550 nm

-No fiber break and no sheath damage


6


Water Penetration Test IEC 794-1-F5B

-Height of water: 1m

-Sample length: 3m

-Test time: 24 hours

-No water shall have leaked from the opposite end of cable.

7


Temperature Cycling Test IEC 794-1-F1

-Temperature step:

+20℃→-40℃→+70℃→+20 ℃

-Time per each step: 12hrs

-Number of cycle: 2

-Loss change≤ 0.05dB @1550 nm

-No fiber break and no sheath damage

-No sheath damage


8

Compound Flow IEC 794-1-E14

-Sample length: 30cm

-Temp: 70°C± 2°C

-Time: 24 hours


- No compound flow


7. Packing


7.1 Each single cable length been wound on an iron wooden drum.


7.2 Standard drum length is 4000m ±2% or customer order


7.3 Covered by plastic buffer sheet.


7.4 Sealed by strong wooden battens.


7.5 At least 3m of cable inner end should be reserved for testing.



Note : The value “D” contain the seal dimension.



China GYTS G652D Outdoor Fiber Optic Cable supplier

GYTS G652D Outdoor Fiber Optic Cable

Inquiry Cart 0